Vibronic
Point level detection
Liquiphant FTL85

Coated point level switch for liquids for FailSafe overfill prevention

  • Liquiphant FailSafe FTL85 ©Endress+Hauser
  • Vibronic measuring principle

  • Functional safety SIL in process instrumentation

  • Liquiphant with permanent function check is the safe choice for point level detection in liquids

Liquiphant FTL85 is a coated point level switch for use in hazardous areas with all international certificates. FailSafe overfill prevention in applications with functional safety up to SIL3 with one device. With high corrosion-resistant coating made of enamel, ECTFE and various PFA materials. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.

Voordelen

  • Use in safety systems requiring functional safety to SIL3 in accordance with IEC 61508 Ed.2.0/ IEC 61511-1/ISA 84-1 and DIN EN ISO 13849

  • Proof test: proof testing interval up to 12 years, Slave devices tested at the press of a button

  • Permanent self-monitoring/internal redundancy

  • 4-20mA interface (acc. to NAMUR NE 06/NE 43): easy integration via the switching unit (Nivotester FailSafe FTL825) with a two-channel output (safety contacts) and locking function or direct integration into a safety PLC

  • No adjustment: quick, low-cost startup

  • No mechanically moving parts: no maintenance, no wear, long operating life

  • Monitoring of fork for damage, corrosion, buildup and mechanical blocking

Toepassingsgebied

Point level switch for liquids up to SIL3.

  • Process connections: Threads and flanges

  • Temperature: -50 to +150°C (-76 to +300°F)

  • Pressure: -1 to +40bar (-14.5 to +580psi)

  • Sensor length: Extension pipe up to 3m (9.8ft)

  • Sensor material: Enamel, ECTFE and various PFA materials

  • International explosion protection certificates, overfill prevention WHG, SIL