S.A. Style universal range of application usable with or without a thermowell spring loaded for use in thermowell Options available to construct removable inserts (spare parts)
Thermowell / protection tube
to use with or without thermowell (can be ordered separately)
Insert / probe
mineral insulated (MI), flexible
Max. immersion length on request
up to 2.000 mm (78,74'')
Material protection tube/ thermowell
1.4401 (316) 1.4841 (310) Alloy 600 (2.4816)
Optional coating
Not defined
Process connection
Union nipple: NPT 1/2" G1/2"
Tip shape
straight
Operating temperature range
Type J: -210 ...760 °C (-346 ...1.400 °F) Type K: -270 ...1.100 °C (-454 ...2.012 °F) Type N: -270 ...1.100 °C (-454 ...2.012 °F) Type T: -270 ...400 °C (-454 ...725 °F)
Max. process pressure (static)
at 20 °C: 10 bar (150 psi) without thermowell
Accuracy
class 1 acc. to IEC 60584
Response time
depending on configuration
Integration head transmitter
yes (4 ... 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
We maken gebruik van cookies om uw browse-ervaring te verbeteren, statistische gegevens te verzamelen om de site-functionaliteit te optimaliseren en om reclame of content op maat te presenteren.
Door "Accepteer alles" te selecteren gaat u akkoord met ons gebruik van cookies.
Bekijk voor meer details onze cookie-richtlijnen .