Specs at a glance
-
Measurement range
0,1 - 10ppm total chlorine; pH 6,5 - 9,5
-
Process temperature
5°C - 45°C
-
Process pressure
0bar - 3bar
Field of application
CCS120 is the analog sensor for standard measurement of total chlorine. It delivers reliable values even if fluctuations in flow or conductivity occur and allows control of the disinfection loop so that the water is free of germs. At the same time, the sensor is designed for long calibration and service intervals reducing your maintenance effort.
CCS120 measures total chlorine in:
Drinking and process water
- Process and distribution networks
- Monitoring, control and optimization of disinfection processesWastewater treatment plants
- Disinfection monitoring and control in wastewater outlet
- Reuse of outlet waterUtilities of all industries
- All disinfection measuring points
Benefits
Recalibration intervals approx. 1 to 3 months under constant operating conditions
Easy membrane replacement thanks to prefabricated membrane cap
Measured values are not affected by conductivity fluctuation
Measurement virtually independent of flow rate in the range above 30 l/h
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Measuring principle
Total chlorine
-
Application
Potable water,Process water, Waste water, pools
-
Characteristic
Amperometric measurement of total chlorine.
-
Measurement range
0,1 - 10ppm total chlorine; pH 6,5 - 9,5
-
Measuring principle
- Total chlorine consists of free chlorine (HOCl, OCl) and bounded chlorine (chloramines).
- A constant polarisation voltage between working and counter electrode instigates the electrochemical reaction.
- Only slightly pH dependent. -
Design
Closed amperometric two electrode sensor for continuous measurement of total chlorine.
-
Material
Sensor shaft : PVC
Membrane cap : PPE -
Dimension
Diameter : appr. 25mm
Length : 210mm -
Process temperature
5°C - 45°C
-
Process pressure
0bar - 3bar
-
Temperature sensor
Including NTC-temperature sensor.
-
Connection
TOP68 plug-in head
Configure to download the CAD drawings of this product
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
Related products