Proline Cubemass C 300
Coriolis flowmeter

Picture of Coriolis flowmeter Proline Cubemass C 300 / 8C3B ©Endress+Hauser

Proline Cubemass C 300

The Coriolis Flow Measuring Principle

Compact sensor for smallest quantities with a compact, easily accessible transmitter

Cubemass C is the ideal sensor for the measurement of smallest flow rates in skids, test rigs and industrial robotics. Neither high pressure nor alternating flow conditions compromise its accuracy. With its compact transmitter Cubemass C 300 offers high flexibility in terms of operation and system integration: access from one side, remote display, improved connectivity options. Heartbeat Technology ensures compliance and process safety at all times.

  • Voordelen

    • Space-saving installation – compact single-tube design

    • Fewer process measuring points – multivariable measurement (flow, density, temperature)

    • Suitable for skids – lightweight sensor

    • Full access to process and diagnostic information – numerous, freely...

  • Toepassingsgebied

    • Measuring principle operates independently of physical fluid properties such as viscosity or density

    • Measuring accurately smallest quantities of liquids and gases.

    Device properties

    • Nominal diameter: DN 1 to 6 (1/24 to 1/4")

    • Process pressure up to 400...

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Coriolis

  • Product headline

    Compact sensor for smallest quantities with a compact, easily accessible transmitter. Measuring accurately smallest quantities of liquids and gases.

  • Sensor features

    Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi).

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access.

  • Nominal diameter range

    DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")

  • Wetted materials

    Measuring tube: 1.4539 (904L)
    Connection: 1.4539 (904L); 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.10 %
    Volume flow (liquid): ±0.10 %
    Mass flow (gas): ±0.50 %
    Density (liquid): ±0.0005 g/cm3

  • Measuring range

    0 to 1000 kg/h (0 to 37 lb/min)

  • Max. process pressure

    PN 40, Class 300, 10K, 400 bar (5800 psi)

  • Medium temperature range

    –50 to +205 °C (–58 to +401 °F)

  • Ambient temperature range

    Standard: –40 to +60 °C (–40 to +140 °F)
    Option: –50 to +60 °C (–58 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L

  • Degree of protection

    IP66/67, type 4X enclosure

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available

  • Outputs

    3 outputs:
    4-20 mA HART (active/passive)
    4-20 mA WirelessHART
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Double pulse output (active/passive)
    Relay output

  • Inputs

    Status input
    4-20 mA input

  • Digital communication

    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)"

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV attestation)

  • Pressure approvals and certificates

    CRN

  • Material certificates

    3.1 material

  • Meetprincipe

    Coriolis

  • Product headline

    Compact sensor for smallest quantities with a compact, easily accessible transmitter. Measuring accurately smallest quantities of liquids and gases.

  • Sensor features

    Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi).

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access.

  • Nominal diameter range

    DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")

  • Wetted materials

    Measuring tube: 1.4539 (904L)
    Connection: 1.4539 (904L); 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.10 % Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm3

  • Measuring range

    0 to 1000 kg/h (0 to 37 lb/min)

  • Max. process pressure

    PN 40, Class 300, 10K, 400 bar (5800 psi)

  • Medium temperature range

    –50 to +205 °C (–58 to +401 °F)

  • Ambient temperature range

    Standard: –40 to +60 °C (–40 to +140 °F)
    Option: –50 to +60 °C (–58 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L

  • Degree of protection

    IP66/67, type 4X enclosure

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available

  • Outputs

    3 outputs:
    4-20 mA HART (active/passive)
    4-20 mA WirelessHART
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Double pulse output (active/passive)
    Relay output

  • Inputs

    Status input
    4-20 mA input

  • Digital communication

    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV attestation)

  • Pressure approvals and certificates

    CRN

  • Material certificates

    3.1 material

  • Meetprincipe

    Coriolis

  • Product headline

    Compact sensor for smallest quantities with a compact, easily accessible transmitter. Measuring accurately smallest quantities of liquids and gases.

  • Sensor features

    Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi).

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access.

  • Nominal diameter range

    DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")

  • Wetted materials

    Measuring tube: 1.4539 (904L)
    Connection: 1.4539 (904L); 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.10 %
    Volume flow (liquid): ±0.10 %
    Mass flow (gas, Tantalum only): ±0.50 %
    Density (liquid): ±0.0005 g/cm³

  • Measuring range

    0 to 1000 kg/h (0 to 37 lb/min)

  • Max. process pressure

    PN 40, Class 300, 10K, 400 bar (5800 psi)

  • Medium temperature range

    Tantalum: –50 to +150 °C (–58 to +302 °F)
    Zirconium: –50 to +205 °C (–58 to +401 °F)

  • Ambient temperature range

    Standard: –40 to +60 °C (–40 to +140 °F)
    Option: –50 to +60 °C (–58 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L

  • Degree of protection

    IP66/67, type 4X enclosure

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available"

  • Outputs

    3 outputs:
    4-20 mA HART (active/passive)
    4-20 mA WirelessHART
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Double pulse output (active/passive)
    Relay output

  • Inputs

    Status input
    4-20 mA input

  • Digital communication

    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV attestation)

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
  • 31
    • Nr 31 Order code 71323007

      Kit power supply, 100-230VAC, Ex

      Gebruik: Promag/Promass 300/500, Prosonic Flow 300, transmitterbehuizing, elektronisch compartiment.

    • Nr 31 Order code 71323008

      Kit power supply, 24VDC, Ex

      Gebruik: Promag/Promass 300/500 Prosonic Flow 300, transmitterbehuizing, electronisch compartiment.

    • Nr 31 Order code 71323009

      Kit pow.supply,100-230VAC/24VDC, Non-haz

      Gebruik: Promag/Promass/Prosonic Flow 300/500 digitaal. Niet gevaarlijk, Zone 2, transmitterbehuizing, electronisch compartment.

  • 39
    • Nr 39 Order code 71185788

      Kit T-DAT, Promass 100

      Gebruik: Promag / Promass 100/300/500, 500 digitaal, Prosonic Flow E 100, Prosonic Flow 300, 500 digitaal, Promag 400(C). (C)= generatie index C.

  • 33
  • 37
    • Nr 37 Order code 71323010

      Kit module cartridge, 300/500, Ex

      Gebruik: Transmitterbehuizing, elektronisch compartiment. Bestaat uit: module cartridge incl. interconnectie board.

  • 34
  • 37
    • Nr 37 Order code 71323011

      Kit module cartridge, 300, Non-haz

      Gebruik: transmitterbehuizing, elektronisch compartiment. Bestaat uit: module cartridge incl. interconnectie board.

  • 46
  • 35
  • 45
    • Nr 45 Order code 71323073

      Kit conn.terminal option A, 300, Non-haz

      Gebruik: transmitterbehuizing Alu/hygiënisch aansluitruimte. Optie A= HART, Profibus PA, FOUNDATION Fieldbus. Bestaat uit: 1x aansluiting 2-Pol., 1x aansluiting 3-Pol., 1x aansluiting 4-Pol.

  • 50
  • 45
    • Nr 45 Order code 71323074

      Kit conn.terminal option B, 300, Non-haz

      Gebruik: transmitterbehuizing Alu/hygiënisch, aansluitcompartiment. Optie B= EtherNet, PROFINET. Bestaat uit: 1x aansluitklem 3-pol., 1x aansluitklem 4-pol.

    • Nr 45 Order code 71327818

      Kit conn.terminal option C, 300, Non-haz

      Gebruik: transmitterbehuizing Alu/hygiënisch aansluitruimte. Optie C = PROFIBUS-DP, Modbus RS485. Bestaat uit: 1x aansluiting 2-Pol., 1x aansluiting 3-Pol., 1x aansluiting 4-Pol.

    • Nr 45 Order code 71323075

      Kit conn.terminal option A, 300/500, Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie A= HART, Profibus PA, FOUNDATION Fieldbus. Bestaat uit: 2x aansluiting 2-Pol., 1x aansluiting 4-Pol.

    • Nr 45 Order code 71323076

      Kit conn.terminal option B, 300/500, Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie B= Ethernet, PROFINET. Bestaat uit: 2 x aansluiting 2-Pol.

    • Nr 45 Order code 71327819

      Kit conn.terminal option C, 300/500, Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie C= PROFIBUS-DP, Modbus RS485. Bestaat uit: 2x aansluiting 2-Pol., 1x aansluiting 4-Pol.

  • 49
    • Nr 49 Order code 71323079

      Kit terminal, transm.,remote display,300

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte met afstands display DKX001. Bestaat uit: 1x aansluiting 4-Polig.

  • 20
    • Nr 20 Order code 71323016

      Kit cover, sight glass, Alu,Non-haz/Exde

      Gebruik: Promag/Promass/Prosonic Flow 300, transmitterbehuizing Alu, Niet gevaarlijk. Promag/Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, kijkglas, O-Ring 110.7x3.53 HNBR.

    • Nr 20 Order code 71323017

      Kit cover,glass, Alu, -50oC,Non-haz/Exde

      Gebruik: Promass/Prosonic Flow 300, transmitterbehuizing Alu, niet- gevaarlijk. Promag 500, Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, kijkglas, O-ring 110,7 x 3,53 FVMQ, -50°C/-58°F.

  • 21
    • Nr 21 Order code 71323018

      Kit cover, blind, Alu, Non-haz/Exde

      Gebruik: Promag/Promass/Prosonic Flow 300, transmitterbehuizing Alu, niet- gevaarlijk. Promag/Promass/Prosonic Flow 300, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, O-ring 110,7 x 3,53 HNBR.

    • Nr 21 Order code 71323019

      Kit cover, blind, Alu,-50oC,Non-haz/Exde

      Gebruik: Promass/Prosonic Flow 300, transmitterbehuizing Alu, Niet- gevaarlijk. Promass/Prosonic Flow 300, transmitterbehuizing Alu, Ex. Bestaat uit: Alu deksel, O-Ring 110,7x3,53 FVMQ, -50°C/-58°F.

  • 20
    • Nr 20 Order code 71323020

      Kit cover, sight glass, Alu, Exd

      Gebruik: Promag /Promass 300/500, Prosonic Flow 300 Transmitterbehuizing Alu, Ex. Bestaat uit: Alu deksel, kijkglas, O-Ring 110,7x3,53 HNBR.

    • Nr 20 Order code 71323021

      Kit cover, sight glass, Alu, -50oC, Exd

      Gebruik: Promag 500, Promass 300/500, Prosonic Flow 300, transmitterbehuizing Alu, Ex. Bestaat uit: Alu deksel, kijkglas, O-Ring 110,7x3,53 FVMQ, -50°C/-58°F.

  • 21
    • Nr 21 Order code 71323022

      Kit cover, blind, Alu, Exd

      Gebruik: Promag/Promass/Prosonic Flow 300, transmitterbehuizing Alu, Ex. Bestaat uit: Alu afdekking, O-ring 110,7 x 3,53 HNBR.

    • Nr 21 Order code 71323023

      Kit cover, blind, Alu, -50oC, Exd

      Gebruik: Promass/Prosonic Flow 300, transmitterbehuizing Alu, Ex. Bestaat uit: Alu afdekking, O-ring 110,7 x 3,53 FVMQ, -50°C/-58°F.

  • 70
    • Nr 70 Order code 71323026

      Kit cover gasket, sight glass/blind

      Gebruik: Promag/Promass 300/500, Prosonic Flow 300, transmitterbehuizing Alu/gegoten. Bestaat uit: 10x O-Ring 110.7x3.53 HNBR.

    • Nr 70 Order code 71323027

      Kit cover gasket,sight glass/blind,-50oC

      Gebruik: Promag 500, Promass 300/500, Prosonic Flow 300, transmitterbehuizing Alu/gegoten, Bestaat uit: O-Ring 110,7x3,53 FVMQ, -50°C/-58°F.

  • 22
    • Nr 22 Order code 71323028

      Kit cover, electr.compart., Alu, Non-haz

      Gebruik: Promag/Promass/Prosonic Flow 300, Alu transmitterbehuizing, Niet- gevaarlijk. Bestaat uit: Alu dekstel, O-Ring 117,1x3,53 HNBR.

    • Nr 22 Order code 71323029

      Kit cover,electronic, Alu,- 50oC,Non-haz

      Gebruik: Promass/Prosonic Flow 300, Alu transmitterbehuizing, Niet- gevaarlijk. Bestaat uit: Alu deksel O-Ring 117,1x3,53 FVMQ, -50°C/-58°F.

  • 74
    • Nr 74 Order code 71323030

      Kit cover gasket,electr.compart.,Non-haz

      Gebruik: Promag/Promass/Prosonic Flow 300, Alu transmitterbehuizing, Niet- gevaarlijk. Bestaat uit: 10x O-Ring 117,1x3,53 HNBR.

    • Nr 74 Order code 71323031

      Kit cover gasket,electr., -50oC, Non-haz

      Gebruik: Promass/Prosonic Flow 300, Alu transmitterbehuizing, Niet- gevaarlijk. Bestaat uit: O-Ring 117,1x3,53 FVMQ, -50°C/-58°F.

  • 22
    • Nr 22 Order code 71323032

      Kit cover, electronic compart., Alu, Ex

      Gebruik: Promag/Promass 300/500, Prosonic Flow 300, transmitterbehuizing Alu, Ex. Bestaat uit: Alu afdekking, O-ring 120,2 x 3,53 HNBR.

    • Nr 22 Order code 71323033

      Kit cover, electr.compart., Alu,-50oC,Ex

      Gebruik: Promag 500, Promass 300/500, Prosonic Flow 300, transmitterbehuizing Alu, Ex. Bestaat uit: Alu afdekking, O-ring 120,2 x 3,53 FVMQ, -50°C/-58°F.

  • 74
    • Nr 74 Order code 71323036

      Kit cover gasket, electronic compart.,Ex

      Gebruik: Promag/Promass 300/500, Prosonic Flow 300, transmitterbehuizing Alu/gegoten, Ex. Bestaat uit: 10x O-ring 120,2 x 3,53 HNBR.

    • Nr 74 Order code 71323037

      Kit cover gasket,elect.compart.,-50oC,Ex

      Gebruik: Promag 500, Promass 300/500, Prosonic Flow 300, transmitterbehuizing Alu/gegoten, Ex. Bestaat uit: O-ring 120,2 x 3,53 FVMQ, -50°C/-58°F.

  • 28
    • Nr 28 Order code 71323044

      Kit cover, remote display, Alu

      Gebruik: Remote display DKX001, behuizing Alu. Bestaat uit: afdekking Alu, O-ring 88,50 x 3,53 HNBR.

    • Nr 28 Order code 71323045

      Kit cover, remote display, Alu, -50oC

      Gebruik: Remote display DKX001, behuizing Alu. Bestaat uit: afdekking Alu, O-ring 88,50 x 3,53 FVMQ, -50°C/-58°F.

  • 76
    • Nr 76 Order code 71323048

      Kit cover gasket, remote display

      Gebruik: Remote display DKX001, behuizing Alu/cast. Bestaat uit: 10x O-ring 88,50 x 3,53 HNBR.

    • Nr 76 Order code 71323049

      Kit cover gasket, remote display, -50oC

      Gebruik: Remote display DKX001, behuizing Alu/cast. Bestaat uit: O-ring 88,50 x 3,53 FVMQ, -50°C/-58°F.

  • 71
    • Nr 71 Order code 71323071

      Kit interface gaskets, 300/500

      Gebruik: Promass 300/500, Prosonic Flow 300, transmitterbehuizing/sensor of transmitterbehuizing/wandmontage Bestaat uit: 5x O-Ring 88,50x3,53 HNBR voor interface.

    • Nr 71 Order code 71323072

      Kit interface gaskets, 300/500, -50°C

      Gebruik: Promass 300/500, Prosonic Flow 300, transmitterbehuizing/sensor of transmitterbehuizing/wandmontage. Bestaat uit: O-Ring 88,50x3,53 FVMQ voor interface, -50°C/-58°F.

  • 11
    • Nr 11 Order code 71368488

      Kit protective cover optionA,300,Non-haz

      Gebruik: Transmitter behuizing Alu/hygiënisch, Aansluitcompartiment. Optie A= HART, PROFIBUS PA, PROFIBUS DP, Modbus RS485, FOUNDATION Fieldbus. Bestaat uit: Aansluitscherm beschermkap, Display drager, 2x schroef M4x10.

    • Nr 11 Order code 71368489

      Kit protective cover optionB,300,Non-haz

      Gebruik: Transmitter behuizing Alu/hygiënisch, Aansluitcompartiment. Optie B= EtherNet, PROFINET. Bestaat uit: Aansluitscherm beschermkap, Display drager, 2x schroef M4x10

    • Nr 11 Order code 71323081

      Kit protective cover option A,300/500,Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie A= HART, Profibus PA, Profibus DP, Modbus RS485, FOUNDATION Fieldbus. Bestaat uit: Aansluitruimte beschermhoes, vertoning vervoerder, 2x schroef M4x10.

    • Nr 11 Order code 71323082

      Kit protective cover option B,300/500,Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie B= Ethernet, PROFINET. Bestaat uit: Aansluitruimte beschermhoes, vertoning vervoerder, 2x schroef M4x10.

  • 87
    • Nr 87 Order code 71343505

      Kit weather protection cover, 300/500

      Gebruik: Promag/Promass 300/500, Prosonic Flow 300, transmitterbehuizing. Bestaat uit: Weer beschermingskap 4404,installatiemateriaal.

    • Order code 71123816

      Mounting plate Cubemass packed

      Universal mounting plate for fixing the flowmeter to various surfaces, such as walls, switchboards etc.

    • Order code 71351317

      Kit wireless antenna extended range

      Bestaat uit: Verbindingskabel in de transmitter, Ex kabelinvoer voor antenne, 1,5 m kabel,antenne,hoek met wartelmoer.

    • Order code 8X3BXX-

      Transmitter Promass 300, 8X3BXX

      Met een geïntegreerde webserver.

    • Order code DKS-

      Promass afichtingset

      Een set bestaat uit 2 afdichtingen

    • Order code DK8CS-

      Cubemass, montageset

      Adapters voor verschillende standaards, voor proces aansluitingen. Te monteren op de Cajon koppelingen.

    • Order code DKX001-

      Remote Display DKX001

    • Order code DKX002-

      Connection Cable for Remote Display

      Connectie kabel voor externe display DKX001 van Proline 300.

    • Order code XPRFID-

      Spare RFID TAG

      Bestaat uit: RFID-tag, het bevestigen draad, krimp mouw.