Proline t-mass F/I 300/500 – The thermal mass flowmeter with long-term stability and a keen sense for utility gases

The Thermal Flow Measuring Principle

Insertion flowmeter with long-term stability as remote version with up to 4 I/Os

The patented sensor design of t-mass I provides unprecedented measurement stability in thermal insertion mass flow measurement. It compensates in real time for changes of process conditions: temperature, pressure, flow direction and gas type. The innovative remote transmitter of t-mass I 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology ensures measurement reliability and compliant verification.

Snelle selectie

Kies uit één van de voorgestelde opties
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

of

Individuele configuratie

Ga verder met uw keuze uit alle mogelijke opties
  • Voordelen

    • Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof

    • High level of process control – premium measurement accuracy and repeatability

    • Reliable monitoring – detection of process disturbances and reverse flow

    • ...

  • Toepassingsgebied

    • Measuring principle is characterized by a high operable flow range and direct mass flow measurement

    • Measurement of utility and process gases and gas mixtures in circular piping or rectangular ducts

    Device properties

    • Insertion version for DN 80 to 1500...

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Thermal

  • Product headline

    Insertion flowmeter with drift-free sensor as remote version with up to 4 I/Os. Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof. Measurement of utility and process gases as well as gas mixtures in circular piping or rectangular ducts.

  • Sensor features

    High level of process control – premium measurement accuracy and repeatability. Reliable monitoring – detection of process disturbances and reverse flow. Flexible installation – suitable for large dimensional range and circular pipes or rectangular ducts. Insertion version for DN 80 to 1500 (3 to 60"). Bidirectional measurement; high measuring performance.

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access.

  • Nominal diameter range

    DN 80 to 1500 (3 to 60")

  • Wetted materials

    Materials for insertion tube
    Stainless steel, 1.4404 (316/316L)
    Process connections, process coupling
    Stainless steel, 1.4404 (316/316L)
    Sensing element
    Unidirectional
    Stainless steel, 1.4404 (316/316L)
    Alloy C22, 2.4602 (UNS N06022);
    Bidirectional
    Stainless steel, 1.4404 (316/316L)
    Reverse flow detection
    Stainless steel, 1.4404 (316/316L)
    Clamping rings
    PEEK
    PVDF
    1.4404 (316/316L)
    Flat ring seal
    EPDM
    FKM

  • Measured variables

    Massflow, temperature, standard volume flow, volume flow, Free air delivery, velocity, heat flow, energy flow, density

  • Max. measurement error

    Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)

  • Measuring range

    20 to 733501 kg/h (44 to 1669340 lb/h)

  • Max. process pressure

    -0.5 to 20 bar_g (-7.25 to 290 psi_g)

  • Medium temperature range

    -40 °C to +180°C (-40 °F to +356°F)

  • Ambient temperature range

    -40 to 60°C (-40 to 140°F)
    Optional:
    Transmitter: -50 to 60°C (-50 to 140°F),
    Sensor: -60 to 60°C (-60 to 140°F)

  • Transmitter housing material

    Aluminium, AlSi10Mg, coated
    Polycarbonate

  • Degree of protection

    IP66/67, Type 4X enclosure Sensor: IP68, Type 6P (optional)

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available

  • Outputs

    4-20 mA HART (active/passive)
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Relay output

  • Inputs

    Status input
    4-20 mA input

  • Digital communication

    HART, Modbus RS485

  • Power supply

    DC 24V
    AC 100 to 240V

  • Hazardous area approvals

    ATEX, cCSAus, IECEx, NEPSI, JPN

  • Product safety

    CE, C-tick

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a

  • Pressure approvals and certificates

    CRN

  • Material certificates

    3.1 material
    NACE MR0175/MR0103

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
  • 31
    • Nr 31 Order code 71323009

      Kit pow.supply,100-230VAC/24VDC, Non-haz

      Gebruik: Promag/Promass/Prosonic Flow/t-mass 300/500 digitaal. Niet gevaarlijk, Zone 2, transmitterbehuizing, electronisch compartment.

  • 47
    • Nr 47 Order code 71323012

      Kit main elec. extender, 500 dig., Ex

      Gebruik: Promass/t-mass 500 digitaal, transmitterbehuizing electronisch compartiment.

    • Nr 47 Order code 71323013

      Kit main elec.extender,500 dig., Non-haz

      Gebruik: Promag/Promass/Prosonic Flow/ t-mass 500 digitaal, Transmitterbehuizing, elektronisch compartiment.

  • 36
    • Nr 36 Order code 71323015

      Kit ISEM extender, 500 digital, Ex

      Gebruik: Promag/Promass/t-mass 500 digitaal, Sensor aansluitbehuizing.

  • 33
    • Nr 33 Order code XPD0052-

      ISEM electr.mod., t-mass 300/500 digital

      Usage: t-mass 300/500 digital. Valid for approvals acc. feature 010. ISEM module V305-02.

  • 39
    • Nr 39 Order code 71185788

      Kit T-DAT, Promass 100

      Gebruik: Promag/Promass 100/300/500, 500 digitaal, Prosonic Flow E 100, Prosonic Flow/t-mass 300, 500 digitaal, Promag 400(C). (C) = generatie index C.

  • 33
    • Nr 33 Order code XPD0054-

      ISEM electr.mod., t-mass 500 digital

      Usage: t-mass 500 digital. Valid for approvals acc. feature 010. ISEM module V305-00.

  • 34
  • 46
    • Nr 46 Order code 71323006

      Kit ISEM ribbon cable, 500 digital

      Gebruik: Promag/Promass/t-mass 500 digitaal, sensoraansluiting.

  • 35
  • 50
  • 45
    • Nr 45 Order code 71323077

      Kit terminal option A, 500 dig., Non-haz

      Gebruik: transmitterbehuizing Alu/polycarbonaat, aansluitruimte. Optie A= HART, Profibus PA, FOUNDATION Fieldbus. Bestaat uit: 1x aansluiting 2-Pol., 1x aansluiting 3-Pol., 1x aansluiting 4-Pol., 1x aansluitklem 6-Pol.

    • Nr 45 Order code 71327820

      Kit terminal option C, 500 dig., Non-haz

      Gebruik: transmitterbehuizing Alu/polycarbonaat, aansluitruimte. Optie C = PROFIBUS-DP, Modbus RS485. Bestaat uit: 1x aansluiting 2-Pol., 1x aansluiting 3-Pol., 1x aansluiting 4-Pol., 1x aansluitklem 6-Pol.

  • 20
    • Nr 20 Order code 71384170

      Kit cover, alu,Promag 400(C),500 digital

      Gebruik: Promag 400(C) = generatie-index C, Promag/Promoties/Prosonische Flow/t- massa 500 digitaal, transmitterbehuizing Alu. Bestaat uit: deksel Alu compleet inbegrepen O-ring 196,40x3,53 HNBR, standaard en -50°C/-58°F, draad met schroefvergrendeling 1,5x150.

    • Nr 20 Order code 71408508

      Kit cover, polycarb., 500 digital

      Gebruik: Promag/Promass/Prosonic Flow/t-mass 500 digitaal, transmitter met polycarbonaat behuizing. Bestaat uit: Afdekpolycarbonaat compleet, O-ring 196,44x3,53 VMQ, standaard en -50°C/-58°F, draad met schroefvergrendeling 1,5x150.

  • 70
    • Nr 70 Order code 71278078

      Kit 10 cover gasket, alu, 400(C)

      Gebruik: Promag 400(C) = generatie index C, Promag/Promass/Prosonic Flow/t-mass 500 digitaal, transmitterbehuizing Alu. Bestaat uit: 10x O-Ring 196,40x3,53 HNBR, default and -50°C/-58°F.

    • Nr 70 Order code 71278077

      Kit 10 afdichtingsring, polycarbonaat

      Gebruik: Promag 400(C) = generatie index C, Promag/Promass/Prosonic Flow/t-mass 500 digitaal, transmitterbehuizing polycarbonaat. Bestaat uit: 10x O-Ring 196,44x3,53 VMQ.

  • 24
    • Nr 24 Order code 71228796

      Kit cover, remote, Alu

      Gebruik: Promag 400(C)= generatie index C, Promag 500, Promag/Promass/Prosonic Flow/t-mass 500 digitaal,sensoraansluiting behuizing. Bestaat uit: afdekking Alu, O-Ring 113,90x3,53 HNBR.

    • Nr 24 Order code 71323050

      Kit cover, remote, Alu, -50oC

      Gebruik: Promass/Prosonic Flow/t-mass 500 digitaal,sensoraansluiting behuizing. Bestaat uit: afdekking Alu, O-Ring 113,90x3,53 FVMQ, -50°C/-58°F.

  • 73
    • Nr 73 Order code 71323051

      Kit housing gaskets, remote, Alu

      Gebruik: Promass/Prosonic Flow/t-mass 500 digitaal sensoraansluiting behuizing. Bestaat uit: O-Ring 113,90x3,53 HNBR voor dekking, pakking EPDM voor huisvesting/sensor.

    • Nr 73 Order code 71323052

      Kit housing gaskets, remote, Alu, -50°C

      Gebruik: Promass/Prosonic Flow/t-mass 500 digitaal, sensoraansluiting behuizing. Bestaat uit: O-Ring 113,90x3,53 FVMQ voor dekking, -50°C/-58°F, pakking FVMQ voor huisvesting/sensor, -50°C/-58°F.

  • 24
    • Nr 24 Order code 71323063

      Kit cover, remote, cast, Ex

      Gebruik: Promag/Promass/Prosonic Flow/t-mass 500 digitaal,sensoraansluiting behuizing. Bestaat uit: deksel gegoten, O-Ring 120,2x3,53 HNBR.

    • Nr 24 Order code 71323064

      Kit cover, remote, cast, -50oC, Ex

      Gebruik: Promass 500, Promass/Prosonic Flow/t-mass 500 digitaal, sensoraansluiting behuizing. Bestaat uit: deksel gegoten, O-ring 120,2 x 3,53 FVMQ,-50°C/-58°F

  • 73
    • Nr 73 Order code 71323065

      Kit housing gaskets, remote, cast, Ex

      Gebruik: Promass 500, Promass/Prosonic Flow/t-mass 500 digitaal, sensoraansluiting behuizing. Bestaat uit: O-Ring 120,2x3,53 HNBR voor dekking, O-ring 88,50 x 3,53 HNBR voor behuizing/sensor.

    • Nr 73 Order code 71323066

      Kit housing gaskets,remote,cast,-50oC,Ex

      Gebruik: Promass 500, Promass/Prosonic Flow/t-mass 500 digitaal, sensoraansluiting behuizing. Bestaat uit: O-Ring 120,2x3,53 FVMQ voor dekking, -50°C/-58 VAn, O-Ring 88,50x3,53 FVMQ voor behuizing/sensor, -50°C/-58°F.

  • 13
    • Nr 13 Order code 71276494

      Kit securing clamp, screw

      Gebruik: Promass 100, Promag 100, Prosonic Flow E 100/E Warmte, CNGmassa, LPGmassa, LNGmassa. Sensorbehuizing: Promag 400(C), (C) = generatie-index C, Promag/Promass 500, Promag/Promass/Prosonic Flow/t-mass 500 digitaal. Bestaat uit: afdekklem, schroef M4x16.

  • 82
    • Nr 82 Order code 71228792

      Kit display protection, Promag 400(C)

      Gebruik: Promag 400(C) = generatie index C, Promag/Promass/Prosonic Flow/t-mass 500 digitaal, transmitterbehuizing Alu. Bestaat uit: beeldscherm bescherming 1.4301, installatiemateriaal.

  • 87
    • Nr 87 Order code 71343504

      Kit weather protection cover,500 digital

      Gebruik: Promag/Promass/Prosonic Flow/t-mass 500 digitaal, transmitterbehuizing. Bestaat uit: weer beschermingskap 4404.

    • Order code 71346427

      Pipe Mounting kit Transmitter 500digital

    • Order code 71351317

      Kit wireless antenna extended range

      Bestaat uit: Verbindingskabel in de transmitter, Ex kabelinvoer voor antenne, 1,5 m kabel,antenne,hoek met wartelmoer.

    • Order code 6X5BXX-

      Transmitter t-mass 500, 6X5BXX

      With an integrated web server.

    • Order code DK6012-

      t-mass 500, sensor cable set

      Connection Cable (analog and digital) between Sensor Junction Housing and Transmitter for Remote Devices of Proline 500.

    • Order code DK6ML-

      Cold tap, atmospheric pressure, t-mass

      Usage: t-mass 65I, 6BAB, 6TAB, 6I3B, 6I5B. For insertion version. For mounting and extracting the device at atmospheric pressure. Min. insertion length: 335mm (13in).

    • Order code DK6003-

      Hot tap, process pressure, 300/500

      Usage: t-mass 6I3B, 6I5B Insertion and withdrawal of sensor under pressure without process interruption.

    • Order code DK6004-

      Plate conditioner 35 hole, t-mass

      Usage: t-mass I 300/500 -200oC...+400oC / -330...+750oF

    • Order code XPRFID-

      Spare RFID TAG

      Consists of: RFID TAG, fixing wire, crimp sleeve.