Proline Prowirl R 200 / 7R2B

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Vortex

  • Product headline

    The flowmeter with the same accuracy despite line size reduction, available as compact or remote version. Integrated temperature measurement for mass/energy flow of saturated steam. Dedicated for applications with very low or reduced flow.

  • Sensor features

    Cost and time saving – no pipework modifications needed for line size reduction. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. No maintenance – lifetime calibration. Integrated diameter reduction by 1 or 2 line sizes. Nominal diameter (mating pipe) up to DN 250 (10").

  • Transmitter features

    Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust two‐chamber housing.

  • Nominal diameter range

    DN 25 to 250 (1 to 10")

  • Wetted materials

    Measuring tube: 1.4408 (CF3M)
    DSC sensor: 1.4435 (316/316L)
    Connection: 1.4404 (F316/F316L)

  • Measured variables

    Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

  • Max. measurement error

    Volume flow (liquid): ±0.75 %
    Volume flow (steam, gas): ±1.00 %
    Mass flow (liquid): ±0.85%
    Mass flow (steam, gas): ±1.7 %

  • Measuring range

    Liquid: 0.26 to 545 m³/h (0.15 to 321 ft³/min)
    depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
    Steam, gas: 3.6 to 7262 m³/h (2.12 to 4274 ft³/min
    depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)

  • Max. process pressure

    PN 40, Class 300, 20K

  • Medium temperature range

    Standard: –40 to +260 °C (–40 to +500 °F)
    High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
    High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)

  • Ambient temperature range

    Compact version (standard): –40 to +80 °C (–40 to +176 °F)
    Compact version (option): –50 to +80 °C (–58 to +176 °F)
    Remote version (standard): –40 to +85 °C (–40 to +185 °F)
    Remote version (option): –50 to +85 °C (–58 to +185 °F)

  • Sensor housing material

    Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

  • Transmitter housing material

    AlSi10Mg, coated; 1.4404 (316L)

  • Degree of protection

    Compact version: IP66/67, type 4X enclosure
    Sensor remote version: IP66/67, type 4X enclosure
    Transmitter remote version: IP66/67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available

  • Outputs

    4‐20 mA HART (passive)
    4‐20 mA (passive)
    Pulse/frequency/switch output (passive)

  • Inputs

    4‐20 mA (passive)

  • Digital communication

    HART, PROFIBUS PA, FOUNDATION Fieldbus

  • Power supply

    DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
    DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
    DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
    DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, EAC

  • Other approvals and certificates

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

  • Pressure approvals and certificates

    PED, CRN, AD 2000

  • Material certificates

    3.1 material
    NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)

  • Meetprincipe

    Vortex

  • Product headline

    The flowmeter with the same accuracy despite line size reduction, available as compact or remote version. Integrated temperature measurement for mass/energy flow of saturated steam. Dedicated for applications with very low or reduced flow.

  • Sensor features

    Cost and time saving – no pipework modifications needed for line size reduction. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. No maintenance – lifetime calibration. Integrated diameter reduction by 1 or 2 line sizes. Nominal diameter (mating pipe) up to DN 250 (10").

  • Transmitter features

    Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust dual- compartment housing.

  • Nominal diameter range

    DN 25 to 250 (1 to 10")

  • Wetted materials

    Measuring tube: 1.4408 (CF3M)
    DSC sensor: 1.4435 (316/316L)
    Connection: 1.4404 (F316/F316L)

  • Measured variables

    Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

  • Max. measurement error

    Volume flow (liquid): ±0.75 %
    Volume flow (steam, gas): ±1.00 %
    Mass flow (liquid): ±0.85%
    Mass flow (steam, gas): ±1.7 %

  • Measuring range

    Liquid: 0.26 to 545 m³/h (0.15 to 321 ft³/min)
    depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
    Steam, gas: 3.6 to 7262 m³/h (2.12 to 4274 ft³/min
    depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)

  • Max. process pressure

    PN 40, Class 300, 20K

  • Medium temperature range

    Standard: –40 to +260 °C (–40 to +500 °F)
    High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
    High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)

  • Ambient temperature range

    Compact version (standard): –40 to +80 °C (–40 to +176 °F)
    Compact version (option): –50 to +80 °C (–58 to +176 °F)
    Remote version (standard): –40 to +85 °C (–40 to +185 °F)
    Remote version (option): –50 to +85 °C (–58 to +185 °F)

  • Sensor housing material

    Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

  • Transmitter housing material

    AlSi10Mg, coated; 1.4404 (316L)

  • Degree of protection

    Compact version: IP66/67, type 4X enclosure
    Sensor remote version: IP66/67, type 4X enclosure
    Transmitter remote version: IP66/67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available

  • Outputs

    4‐20 mA HART (passive)
    4‐20 mA (passive)
    Pulse/frequency/switch output (passive)

  • Inputs

    4‐20 mA (passive)

  • Digital communication

    HART, PROFIBUS PA, FOUNDATION Fieldbus

  • Power supply

    DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
    DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
    DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
    DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, EAC

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

  • Pressure approvals and certificates

    PED, CRN, AD 2000

  • Material certificates

    3.1 material
    NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)

  • Meetprincipe

    Vortex

  • Product headline

    The flowmeter with the same accuracy despite line size reduction, available as compact or remote version. Integrated temperature measurement for mass/energy flow of saturated steam. Dedicated for applications with very low or reduced flow.

  • Sensor features

    Cost and time saving – no pipework modifications needed for line size reduction. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. No maintenance – lifetime calibration. Integrated diameter reduction by 1 or 2 line sizes. Nominal diameter (mating pipe) up to DN 250 (10").

  • Transmitter features

    Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust two‐chamber housing.

  • Nominal diameter range

    DN 25 to 250 (1 to 10")

  • Wetted materials

    Measuring tube: 1.4408 (CF3M)
    DSC sensor: 1.4435 (316/316L)
    Connection: 1.4404 (F316/F316L)

  • Measured variables

    Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

  • Max. measurement error

    Volume flow (liquid): ±0.75 %
    Volume flow (steam, gas): ±1.00 %
    Mass flow (liquid): ±0.85%
    Mass flow (steam, gas): ±1.7 %

  • Measuring range

    Liquid: 0.26 to 545 m³/h (0.15 to 321 ft³/min)
    depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
    Steam, gas: 3.6 to 7262 m³/h (2.12 to 4274 ft³/min
    depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)

  • Max. process pressure

    PN 40, Class 300, 20K

  • Medium temperature range

    Standard: –40 to +260 °C (–40 to +500 °F)
    High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
    High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)

  • Ambient temperature range

    Compact version (standard): –40 to +80 °C (–40 to +176 °F)
    Compact version (option): –50 to +80 °C (–58 to +176 °F)
    Remote version (standard): –40 to +85 °C (–40 to +185 °F)
    Remote version (option): –50 to +85 °C (–58 to +185 °F)

  • Sensor housing material

    Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

  • Transmitter housing material

    AlSi10Mg, coated; 1.4404 (316L)

  • Degree of protection

    Compact version: IP66/67, type 4X enclosure
    Sensor remote version: IP66/67, type 4X enclosure
    Transmitter remote version: IP66/67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available

  • Outputs

    4‐20 mA HART (passive)
    4‐20 mA (passive)
    Pulse/frequency/switch output (passive)

  • Inputs

    4‐20 mA (passive)

  • Digital communication

    HART, PROFIBUS PA, FOUNDATION Fieldbus

  • Power supply

    DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
    DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
    DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
    DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, EAC

  • Other approvals and certificates

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

  • Pressure approvals and certificates

    PED, CRN, AD 2000

  • Material certificates

    3.1 material
    NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
  • 34
    • Nr 34 Order code 71108602

      I/O module Flow, 2-wr. 2x4-20mA,HART, Ex

      Non-Ex, Ex. Current output, 4-20mA HART + 4-20mA analog. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

    • Nr 34 Order code 71164940

      I/O module, 2-wire, PA/FF, PFS, Ex, V2

      Niet-Ex, Ex. PROFIBUS PA, FOUNDATION Fieldbus. PFS = schakelen output. Versie 2. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Gebruik: Promass 200, Prowirl 200, Promag 200.

  • 36
    • Order code 71128617

      Overvoltage protection (OVP10),1-Channel

      4-20mA HART. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67. Gebruik: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code 71128619

      Overvoltage protection (OVP20),2-Channel

      4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus, Imp./Freq./Switch output. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67. Gebruik: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code 71197334

      Transmitter electronics FHX50

      Bestaat uit: Elektronica, lint kabel. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Gebruik: Promass 200, Prowirl 200, Promag 200, Prosonic Flow 200.

    • Order code

      Remote display FHX50 please order with separate order structure.

    • Order code 71296840

      Plug M12, VA

      To connect FHX50. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Not for dust Ex. Usage: Prowirl 200, Promass 200, Promag 200, Prosonic Flow 200.

  • 30
  • 34
  • 46
  • 34
    • Nr 34 Order code XPD0016-

      I/O module, 2-wire, 4-20mA,HART, PFS, Ex

      Non-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output.

  • 46
  • 34
    • Nr 34 Order code XPD0018-

      I/O,2-wire,4-20mA,HART,PFS,4-20mA input

      Non-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output. 1x current input.

  • 43
  • 44
  • 37
    • Nr 37 Order code 71110280

      Klemmenset 2-dr. , I/O Module

      Consists of: 4x Terminal 2 pole, groen. Gebruik: FMP50/51/52/53/54/55/56/57. Gebruik: Promass TB2.

  • 40
    • Nr 40 Order code XPD0024-

      Display module, SD02, push buttons

      Voor huisvesting: GT18, GT19, GT20. gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Promass 200/TB2, Prosonic Flow 200, t-massa 150, Promag 200, Prowirl 200. Bestaat uit: Weergeven SD02, helix-kabel, lint kabel, connector cover.

    • Nr 40 Order code XPD0025-

      Display module, SD03, Touch Control

      Voor huisvesting: GT18, GT19, GT20. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. FHX50. Promass 200 / TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Bestaat uit: Verlicht beeldscherm SD03, lintkabel, connector.

  • 20
    • Nr 20 Order code 71110281

      Cover GT18 316L, HNBR

      Materiaal: 316L. O-ring, EPDM, PTFE gecoat. Gebruik: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67. Gebruik: Promass 200/ TB2, Prosonic Flow 200, Prowirl 200.

    • Nr 20 Order code 71110282

      Cover GT18 316L, sight glass, HNBR

      Materiaal: 316L. O-ring NBR, PTFE gecoat. Gebruik: FMP51/ 52/54/55/56/57, FMR51/ 52/53/54/57, FMR62/67, FHX50. Gebruik: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

  • 25
    • Nr 25 Order code 71110291

      Cover GT18 316L, terminal Ex, gasket

      Materiaal: 316L. O-ring EPDM, PTFE gecoat. Gebruik: terminal compartiment, niet voor Ex d/XP, FMP51/FMP52/FMP54/FMP55/FMP56/FMP57, FMR51/FMR52/FMR53/FMR54/FMR57, FMR62/FMR67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

    • Nr 25 Order code 71110284

      Cover GT18 316L, terminal Ex d, HNBR

      Materiaal: 316L. O-ring EPDM/PTFE gecoat. Gebruik: terminalcompartiment Ex d/XP, FMP51/ 52/54/55/56/57, FMR51/52/53/54/57, FMR62/67. Gebruik: Promass 200/ TB2, Prosonic Flow 200, Prowirl 200.

    • Nr 25 Order code 71185516

      Cover GT18 316L, Terminal, OVP, gasket

      Materiaal: 316L. O-ring EPDM, PTFE gecoat. Gebruik: terminal compartiment, voor overspanningsbeveiliging, niet voor Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57,FMR50/FMR51/FMR52/FMR53/ FMP54/FMP56/FMP57,FMR62/FMR67. Gebruik: Promass 200, Prosonic Flow 200, Prowirl 200.

  • 20
    • Nr 20 Order code 71110299

      Cover GT20 Alu, HNBR

      Materiaal: aluminium, gecoat. O-ring EPDM, PTFE gecoat. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/ 51/52/53/54/56/57, FMR60/62/67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 20 Order code 71110297

      Deksel GT20 Aluminium, met glasvenster,

      Materiaal: aluminium, gecoat O-ring EPDM, PTFE gecoat. Gebruik: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 25
    • Nr 25 Order code 71110301

      Cover GT20 Alu, Terminal Ex, gasket

      Materiaal: aluminium, gecoat. O-ring EPDM, PTFE gecoat. Gebruik: terminal compartiment, niet voor Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57,FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57,FMR60/FMR62/FMR67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 25 Order code 71110302

      Cover GT20 Alu, Terminal Ex d, gasket

      Materiaal: aluminium, gecoat. O-ring EPDM, PTFE-gecoate. FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 25 Order code 71185517

      Cover GT20 Alu, Terminal, OVP, gasket

      Materiaal: aluminium. O-ring EPDM, PTFE gecoat. Gebruik: terminal compartiment, voor overspanningsbeveiliging, niet voor Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57,FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57,FMR60/FMR62/FMR67. Gebruik: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 24
    • Nr 24 Order code 71223005

      Kit cover, Alu, remote, sensor

      Gebruik: Prowirl 200. Bestaat uit: 1x afdekking Alu, 1x O-ring 75,87 x2,62 NBR coating.

    • Nr 24 Order code 71223006

      Kit cover,Alu,remote,sensor, -50°C/-58°F

      Gebruik: Prowirl 200. Bestaat uit: 1x deksel Alu, 1x O-ring 75,87 x2,62 FVMQ gecoat.

    • Nr 24 Order code 71223009

      Kit cover, 316L, remote, sensor

      Gebruik: Prowirl 200. Bestaat uit: 1x deksel 316L, 1x O-ring 75,87x2,62 NBR coating.

    • Nr 24 Order code 71223011

      Kit cover,316L,remote,sensor,-50°C/-58°F

      Gebruik: Prowirl 200. Bestaat uit: 1x deksel 316L, 1x O-ring 75,87 x2, 62 FVMQ gecoat.

  • 65
    • Nr 65 Order code 71110303

      Sealing set housing GT18,GT19,GT20

      Bestaat uit: O-ring 88.5x3.53 EPDM/PTFE, bedekken elektronica compartiment, behuizing GT19. O-Ring 88.5x3.53 NBR, bedekken elektronica compartiment, huisvesting GT18, GT20. O-ring 91.67x3.53 EPDM/PTFE, bedekken aansluitruimte, behuizing GT19. O-Ring 91.67x3.53 NBR, bedekken aansluitruimte, huisvesting GT18, GT20. O-ring 50.39x3.53 EPDM/PTFE, behuizing/sensor. FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 73
    • Nr 73 Order code 71223053

      Kit gaskets housing, remote, sensor

      Gebruik: Prowirl 200. Bestaat uit: 1x O-ring 75,87x2,62 NBR coating als dekking. 1x O-ring 50,39x3,53 HNBR gecoate voor behuizing / behuizing te ondersteunen.

    • Nr 73 Order code 71223054

      Kit gaskets housing,remote,sensor, -50°C

      Gebruik: Prowirl 200,-50°C/-58°F. Bestaat uit: 1x O-Ring 75.87x2.62 FVMQ als dekking. 1x O-ring 50,39 x3,53 FVMQ voor behuizing/ behuizing te ondersteunen.

  • 15
  • 19
    • Nr 19 Order code 71115174

      Housing filter 316L, GT18, 1 set

      Consists of: filter plug metall 316L. Pressure compensation filter. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

    • Nr 19 Order code 71115175

      Housing filter Brass/Ni GT19/20, 1 set

      Bestaat uit: 2x filterplug messing nikkel. Drukcompensatie filter. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 17
  • 61
    • Order code 71162242

      Weather prot. cover GT18/GT19/GT20, 316L

      Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code 7X2BXX-

      Transmitter Prowirl 200, 7X2BXX

      Voor product: 7F2B, 7D2B, 7R2B, 7O2B.

    • Order code DK7ST-

      Plaat stromingsrichter 35 gaten, Prowirl

      -200...+400°C / -330...+750°F

    • Order code XPRFID-

      Spare RFID TAG

      Bestaat uit: RFID-tag, het bevestigen draad, krimp mouw.

  • Opvolger