Zoek op trefwoord, order- of productcode of serienummer, bv. “CM442” of “Technische informatie”
Voer tenminste 2 karakters in om het zoeken te starten.
  • Geschiedenis
Picture of Coriolis flowmeter LPGmass / 8FE for accurate measurement of liquefied petroleum gas

LPGmass
Coriolis flowmeter

The refueling and distribution application flowmeter with easy system integration

8FE
Please Wait (spinning wheel)
Prijzen worden geladen
Prijzen tijdelijk niet beschikbaar
Price on request
Bezig met activeren van prijs
Prijs: Informatie verstrekken
from CHF ??.-
Filter meting-/ toepassingstaak
Meet-/toepassingstaak

Configureer om de CAD-tekeningen van dit product te downloaden

  • Meetprincipe

    Coriolis

  • Product headline

    The refueling and distribution application flowmeter with easy sytem
    integration. Accurate measurement of liquefied petroleum gas in refueling
    and distribution applications.

  • Sensor features

    Excellent operational safety – reliable under extreme ambient conditions.
    Fewer process measuring points – multivariable measurement (flow,
    density, temperature). Space‐saving installation – no in/outlet run needs.
    Flow rates up to 45 000 kg/h (1654 lb/min). Volume flow calculation
    according to API table 53.

  • Transmitter features

    Easy operation – reduced to application needs. Fast commissioning – pre‐configured devices. Automatic recovery of data for servicing. Robust, ultra‐compact transmitter housing. Pulse output and Modbus RS485.

  • Nominal diameter range

    DN 8 to 40 (³⁄₈ to 1½")

  • Wetted materials

    Measuring tube: 1.4539 (904L)
    Connection: 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow

  • Max. meetfout

    Mass flow (liquid): ±0.2 %
    Volume flow (liquid): ±0.3 %

  • Measuring range

    0 to 45 000 kg/h (0 to 1650 lb/min)

  • Max. process pressure

    PN 40, Class 300, 63K

  • Medium temperature range

    –40 to +125 °C (–40 to +257 °F)

  • Ambient temperature range

    –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    Powder‐coated die‐cast aluminium

  • Degree of protection

    IP67, type 4X enclosure

  • Display/Operation

    No local operation
    Configuration via operating tools possible

  • Outputs

    Pulse/frequency/switch output (passive), phase‐shifted pulse

  • Inputs

    None

  • Digital communication

    Modbus RS485

  • Power supply

    DC 10 to 30 V
    AC 20 to 28 V

  • Hazardous area approvals

    ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI, UL

  • Other approvals and certificates

    3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), custody
    transfer
    PED, CRN

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), custody transfer

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material