Zoek op trefwoord, order- of productcode of serienummer, bv. “CM442” of “Technische informatie”
Voer tenminste 2 karakters in om het zoeken te starten.
  • Geschiedenis
product picture of the ultrasonic flowmeter FLOWSIC600

FLOWSIC600
ultrasonic flowmeter

Reliable flowmeter for process applications

IFL600
Please Wait (spinning wheel)
Prijzen worden geladen
Prijzen tijdelijk niet beschikbaar
Price on request
Bezig met activeren van prijs
Prijs: Informatie verstrekken
Filter meting-/ toepassingstaak
Meet-/toepassingstaak

Configureer om de CAD-tekeningen van dit product te downloaden

  • Meetprincipe

    Ultrasonic transit time difference measurement

  • Measured variables

    Volumetric flow, a. c., volume a. c., gas velocity, sound velocity

  • Measuring Medium

    Natural gas, air, C2H4, steam, process gases (e. g. CO2 up to 100%, N2, O2, Cl2 etc.), gases like sour gas or bio gas with high H2S content

  • Repeatability

    < 0.1 % of the measured value

  • Accuracy

    2-path version ≤ ± 1 %
     
    4-path version ≤ ± 0.5 %
    Typical accuracy, see application specific data for detailed information

  • Medium temperature range

    ATEX:
    –40 °C ... +105 °C at T1, T2, T3;
    –40 °C ... +91 °C at T4
    Other Ex certifications: –40 °C ... +180 °C

  • Operating pressure range

    0 bar (g) ... 250 bar (g)
    On request: Up to 450 bar (g)

  • Nominal pipe size

    2" ... 24"
    (DN 50 ... DN 600)

  • Metrological approvals and certificates

    ISO 17089-2
    MTBF: 15.4 years

  • Hazardous area approvals

    IECEx:
    Gb/Ga Ex db eb ib [ia Ga] IIA T4
    Gb/Ga Ex db eb ib [ia Ga] IIC T4
    Ultrasonic transducers intrinsically safe
     
    ATEX:
    II 1/2 (1) G Ex ia/db eb ia [ia Ga] IIA/IIB/IIC T4...T1 Ga/Gb
    III 1/2 (1) G Ex ia/db eb ia [ia Ga] IIC T6 Ga/Gb
    Ultrasonic transducers intrinsically safe
     
    NEC/CEC (US/CA):
    Class I, Division 1, Groups B, C, D T4
    Class I, Division 2, Groups A, B, C, D T4
    Class I, Division 1, Group D T4
    Class I, Division 2, Group D T4
    Ultrasonic transducers intrinsically safe

  • Digital Outputs

    3 outputs:
    30 V, 10 mA
    Passive, electrically isolated, Open Collector or according to NAMUR (EN 50227), fmax = 6 kHz
    (scalable)

  • Digital communication

    Modbus ASCII
    Modbus RTU
    HART