Zoek op trefwoord, order- of productcode of serienummer, bv. “CM442” of “Technische informatie”
Voer tenminste 2 karakters in om het zoeken te starten.
  • Geschiedenis
Prosonic FMU40 - ultrasone meting

Ultrasone meting
Time of Flight
Prosonic FMU40

Kostenefficiënt instrument voor niveaumetingen in vloeistoffen en vaste stoffen tot 5 m

FMU40
Please Wait (spinning wheel)
Prijzen worden geladen
Prijzen tijdelijk niet beschikbaar
Price on request
from CHF ??.-
  • Meetprincipe

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2/4-wire (HART), PROFIBUS PA, FOUNDATION Fieldbus

  • Accuracy

    +/- 2 mm or +/- 0.2 % of set measuring range 1)

  • Ambient temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process pressure absolute / max. overpressure limit

    0.7 bar ... 3 bar abs
    (10 psi ... 44 psi)

  • Main wetted parts

    PVDF

  • Process connection

    G / NPT 1 1/2"

  • Blocking distance

    0.25 m (0.8 ft)

  • Max. meetafstand

    2 m (6 ft)

  • Communication

    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, TIIS, INMETRO, NEPSI

  • Application limits

    Take notice of range diagram

  • Meetprincipe

    Ultrasonic

  • Product headline

    Compact ultrasonic measuring instrument
    Cost effective solution for open channel

  • Max. meetfout

    Low accuracy

  • Measuring range

    0,25...5m [0.8...16ft]

  • Max. process pressure

    atm.

  • Medium temperature range

    -40°C ... 80°C
    (-40°F...176°F)

  • Degree of protection

    IP68

  • Outputs

    4...20mA(Hart),PA,FF

  • Inputs

    2-wire 16-36V DC,
    4-wire 16-36V DC,
    90-253V AC 50/60Hz

  • Digital communication

    PROFIBUS PA, FOUNDATION Fieldbus

  • Hazardous area approvals

    ATEX, FM, CSA

  • Meetprincipe

    Ultrasonic Limit

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2/4-wire (HART),
    PROFIBUS PA,
    FOUNDATION Fieldbus

  • Ambient temperature

    -40 °C...+80 °C
    (-40 °F...+176 °F)

  • Process temperature

    -40 °C...+80 °C
    (-40 °F...+176 °F)

  • Process pressure absolute / max. overpressure limit

    0.7 bar...3 bar abs
    (10 psi...44 psi)

  • Main wetted parts

    PVDF

  • Process connection

    G / NPT 1 1/2"

  • Blocking distance

    0.25 m (0.8 ft)

  • Communication

    4...20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, INMETRO, NEPSI

  • Application limits

    Take notice of range diagram

  • Meetprincipe

    Ultrasonic Limit

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2/4-wire (HART),
    PROFIBUS PA,
    FOUNDATION Fieldbus

  • Ambient temperature

    -40 °C...+80 °C
    (-40 °F...+176 °F)

  • Process temperature

    -40 °C...+80 °C
    (-40 °F...+176 °F)

  • Process pressure absolute / max. overpressure limit

    0.7 bar...3 bar abs
    (10 psi...44 psi)

  • Main wetted parts

    PVDF

  • Process connection

    G / NPT 1 1/2"

  • Blocking distance

    0.25 m (0.8 ft)

  • Communication

    4...20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, INMETRO, NEPSI

  • Application limits

    Take notice of range diagram

  • Meetprincipe

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2/4-wire (HART), PROFIBUS PA, FOUNDATION Fieldbus

  • Accuracy

    +/- 2 mm or +/- 0.2 % of set measuring range

  • Ambient temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process pressure absolute / max. overpressure limit

    0.7 bar ... 3 bar abs
    (10 psi ... 44 psi)

  • Main wetted parts

    PVDF

  • Process connection

    G / NPT 1 1/2"

  • Blocking distance

    0.25 m (0.8 ft)

  • Application

    Application

  • Max. meetafstand

    Max. meetafstand

  • Communication

    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, TIIS, INMETRO, NEPSI

  • Application limits

    Application limits

Configureer om de CAD-tekeningen van dit product te downloaden