Zoek op trefwoord, order- of productcode of serienummer, bv. “CM442” of “Technische informatie”
Voer tenminste 2 karakters in om het zoeken te starten.
  • Geschiedenis
Prosonic FDU92 - ultrasone meting

Ultrasone meting
Time-of-Flight
Prosonic FDU92

Ultrasone sensor voor niveau- en flowmetingen voor aansluiting op de FMU9x (meetbereik tot 20 m)

FDU92
please wait
Prijzen worden geladen
Prijzen tijdelijk niet beschikbaar
Price on request
from CHF ??.-
  • Meetprincipe

    Ultrasonic

  • Product headline

    Version with separate transmitter in field housing or top hat rail housing
    Cost effective solution for open channel flow measurement in water / wastewater plants

  • Max. meetfout

    accuracy:
    distance measurement: +/- 2mm + 0.17%

  • Measuring range

    max measuring distance up to 20m / 65ft

  • Max. process pressure

    atm.

  • Medium temperature range

    -40...95°C
    (-40...203°F)

  • Degree of protection

    IP68

  • Display/Operation

    Transmitter

  • Outputs

    Transmitter:
    4...20mA HART
    Option: second 4...20mA output

  • Inputs

    Transmitter

  • Digital communication

    HART, PROFIBUS DP

  • Hazardous area approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

  • Meetprincipe

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART , Profibus DP)

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C ... 95 °C
    (-40 °F ... 203 °F)

  • Process temperature

    -40 °C ... 95 °C
    (-40 °F ... 203 °F)

  • Process pressure absolute / max. overpressure limit

    0.7 bar ... 4 bar abs
    (10 psi ... 58 psi)

  • Main wetted parts

    PVDF (fully welded IP68 / NEMA 6P)

  • Process connection

    G / NPT 1"

  • Blocking distance

    0.4 m (1.3 ft)

  • Max. meetafstand

    10 m (33 ft)

  • Communication

    Transmitter:
    4 ... 20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC Ex

  • Options

    Second 4...20mA output

  • Components

    Transmitter:
    FMU90

  • Meetprincipe

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART, Profibus DP)

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C ... 95 °C
    (-40 °F ... 203 °F)

  • Process temperature

    -40 °C ... 95 °C
    (-40 °F ... 203 °F)

  • Process pressure absolute / max. overpressure limit

    0.7 bar ... 4 bar abs
    (10 psi ... 58 psi)

  • Main wetted parts

    PVDF (fully welded IP68 / NEMA 6P)

  • Process connection

    G / NPT 1"

  • Blocking distance

    0.4 m (1.3 ft)

  • Application

    Application

  • Max. meetafstand

    Max. meetafstand

  • Communication

    Transmitter:
    4 ... 20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

  • Options

    Second 4...20 mA output

  • Components

    Transmitter:
    FMU90, FMU95

  • Application limits

    Application limits