Digital 4-electrode conductivity sensor
Memosens CLS82D
Memosens conductive conductivity sensor for hygienic applications in Life Sciences, Pharma and Food
Memosens CLS82D is a hygienic, digital sensor for applications with widely varying conductivity values, where it performs reliably, safe and fast. Numerous certificates, various process connections and a small compact design ensure the perfect fit for your process. With Memosens digital technology, CLS82D combines maximum process and data integrity with simple operation. It resists corrosion and moisture, enables lab calibration and facilitates predictive maintenance.
- F
- L
- E
- X
-
Eenvoudige producten
- Gemakkelijk te selecteren, installeren en gebruiken
Technische topkwaliteit
Eenvoud
-
Standaardproducten
- Betrouwbaar, robuust en onderhoudsarm
Technische topkwaliteit
Eenvoud
-
Gespecialiseerde producten
- Ontworpen voor veeleisende applicaties
Technische topkwaliteit
Eenvoud
Variabel
FLEX selectie | Technische topkwaliteit | Eenvoud |
---|---|---|
Fundamental selectie Voldoe aan uw basismeetvoorwaarden |
Technische topkwaliteit
|
Eenvoud
|
Lean selectie Beheers eenvoudig uw belangrijkste processen |
Technische topkwaliteit
|
Eenvoud
|
Extended selectie Optimaliseer uw processen met innovatieve technologieën |
Technische topkwaliteit
|
Eenvoud
|
Xpert selectie Beheers uw meest uitdagende applicaties |
Technische topkwaliteit
|
Eenvoud
Variabel |
-
Overzicht specificaties
-
Measurement range
1 µS/cm to 500 mS/cm
-
Process temperature
-5 to 120 °C (23 to 248 °F)
Sterilization: max. 140 °C at 6 bar for max. 45 min
(Max. 284 °F at 87 psi for max. 45 min) -
Process pressure
17 bar abs at 20 °C (247 psi at 68 °F)
9 bar abs at 120 °C (131 psi at 248 °F)
-
Snelle selectie
Individuele configuratie
-
Voordelen
Broad measurement range
Hygienic design certified by EHEDG and 3-A
Absolute loop safety thanks to Memosens and unique electrode connection surveillance
Sterilizable and autoclavable
Quality certificate stating the individual cell constant
Logging of sensor...
-
Toepassingsgebied
Memosens CLS82D measures conductivity in applications that need to cover a broad measuring range as in:
Phase separation
Downstream processing
Fermentation
Final rinse in pharma applications
With its international explosion protection approvals, such...
Documenten / handleidingen / software
-
Memosens CLS82D
Technical Information
Conductivity sensor, 4-pin
Technische informatie (TI) -
Memosens CLS82D
Hygiënische geleidbaarheidssensoren
Inbedrijfsstellingsvoorschriften (BA) -
Cleanfit Control CYC25
Operating Instructions
Cleaning unit
Inbedrijfsstellingsvoorschriften (BA) -
Leitfähigkeitsmessung in Industrieprozessen
Auswahl- und Engineeringhilfe für verschiedene Industrien und
AnwendungenCompetentie Brochure (CP)12/19Duits -
Conductivity measurement in industrial processes
Selection and engineering guide for different industries and
applicationsCompetentie Brochure (CP)12/19Engels -
For the love of quality water
Fresh ideas for waterworks, distribution networks, surface waters and
industrial plants.Competentie Brochure (CP)06/19Engels -
Leitfähigkeitsmessung in Wasserrecyclingsanlage
Leitfähigkeitsmessung in Wasserrecyclingsanlage: Präzise Messwerte auch
in niedrigen MessbereichenCase Studie (CS)10/19Duits -
Conductivity measurement in a water reuse plant
Conductivity measurement in a water reuse plant: Precise measured values
even
in low measuring rangesCase Studie (CS)10/19Engels -
Mesure de conductivité dans une installation de réutilisation des eaux
Valeurs mesurées précises même dans des gammes de mesure aux valeurs
bassesCase Studie (CS)10/19fr -
A sensor for any situation
American version: Memosens CLS82D four-electrode conductivity sensor for
the most
stringent hygienic requirementsInnovaties (IN)10/16Engels -
Ein Sensor für alle Fälle
Der Vier-Elektroden-Leitfähigkeitssensor Memosens CLS82D für höchste
HygieneanforderungenInnovaties (IN)03/16Duits -
A sensor for any situation
Memosens CLS82D four-electrode conductivity sensor for the most
stringent hygiene requirementsInnovaties (IN)03/16Engels -
Condumax W CLS82D
Digitaler 4-Pol-Leitfähigkeitssensor mit Memosens-Protokoll in kompakter
pH-
Elektroden Bauform zur Messung von sehr unterschiedlichen
Leitfähigkeiten.
Einsetzbar in der Prozess- und Trinkwasserüberwachung.Tender tekst11/18Duits -
50081902 (United Kingdom)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsEngels -
50081905 (United Arab Emirates)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsEngels -
50081905 (Estonia)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutions -
50081902 (Ukraine)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutions -
50081906 (Russia)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsRussisch -
50081906 (United Arab Emirates)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsEngels -
50081904 (United Kingdom)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsEngels -
50081905 (Ireland)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsEngels -
50081902 (Romania)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsRoemeens -
50081902 (Portugal)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsPortugees -
50081903 (Estonia)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutions -
50081904 (Turkey)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsTurks -
50081905 (Belgium)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsfr -
50081903 (Austria)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsDuits -
50081906 (Ireland)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsEngels -
50081903 (Mexico)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsSpaans -
50081904 (Czech Republic)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsTsjechisch -
50081904 (Estonia)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutions -
50081905 (United Kingdom)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsEngels -
50081904 (Slovenia)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutions -
50081904 (United Arab Emirates)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsEngels -
50081902 (Denmark)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsDeens -
50081905 (Croatia)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutions -
50081902 (Ireland)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsEngels -
50081906 (Denmark)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsDeens -
50081903 (Netherlands)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsNederlands -
50081902 (Greece)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsGrieks -
50081906 (Slovakia)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutions -
50081904 (Bulgaria)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsBulgaars -
50081904 (Belgium)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsfr -
50081905 (Russia)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsRussisch -
50081903 (European Union)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsEngels -
50081905 (Malta)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsEngels -
50081905 (Turkey)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsTurks -
50081904 (Romania)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsRoemeens -
50081903 (Spain)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsSpaans -
50081905 (Sweden)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsZweeds -
50081904 (Canada)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsEngels -
50081902 (Netherlands)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsNederlands -
50081905 (Germany)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsDuits -
50081906 (Italy)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsItaliaans -
50081903 (USA)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsEngels -
50081905 (Italy)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsItaliaans -
50081906 (Hungary)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsHongaars -
50081906 (Lithuania)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutions -
50081906 (Croatia)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutions -
50081903 (Australia)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsEngels -
50081903 (France)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsfr -
50081905 (Portugal)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsPortugees -
50081904 (Mexico)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsSpaans -
50081902 (Croatia)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutions -
50081903 (Sweden)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsZweeds -
50081903 (Slovenia)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutions -
50081902 (China)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsChinees -
50081903 (United Kingdom)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsEngels -
50081906 (Spain)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsSpaans -
50081906 (Czech Republic)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsTsjechisch -
50081906 (Australia)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsEngels -
50081903 (Turkey)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsTurks -
50081904 (Poland)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsPools -
50081902 (Poland)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsPools -
50081905 (Norway)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsNoors -
50081903 (Romania)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsRoemeens -
50081906 (Canada)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsEngels -
50081904 (Russia)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsRussisch -
50081906 (Norway)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsNoors -
50081905 (Netherlands)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsNederlands -
50081902 (Canada)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsEngels -
50081906 (Portugal)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsPortugees -
50081906 (Netherlands)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsNederlands -
50081904 (Finland)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsFins -
50081905 (USA)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsEngels -
50081906 (Slovenia)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutions -
50081902 (Slovenia)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutions -
50081902 (Bulgaria)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsBulgaars -
50081902 (Belgium)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsfr -
50081906 (Belgium)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsfr -
50081903 (Finland)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsFins -
50081906 (USA)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsEngels -
50081903 (Canada)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsEngels -
50081904 (Malta)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsEngels -
50081904 (Slovakia)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutions -
50081906 (Mexico)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsSpaans -
50081906 (Sweden)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsZweeds -
50081902 (United Arab Emirates)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsEngels -
50081902 (New Zealand)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsEngels -
50081906 (Turkey)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsTurks -
50081905 (Romania)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsRoemeens -
50081903 (Norway)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsNoors -
50081906 (New Zealand)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsEngels -
50081904 (Portugal)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsPortugees -
50081903 (Czech Republic)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsTsjechisch -
50081904 (Switzerland)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsDuits -
50081902 (Mexico)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsSpaans -
50081904 (Netherlands)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsNederlands -
50081903 (India)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsEngels -
50081905 (Canada)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsEngels -
50081903 (Ireland)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsEngels -
50081903 (Ukraine)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutions -
50081902 (Hungary)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsHongaars -
50081903 (New Zealand)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsEngels -
50081903 (Bulgaria)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsBulgaars -
50081902 (Slovakia)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutions -
50081904 (Sweden)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsZweeds -
50081905 (Australia)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsEngels -
50081905 (Slovenia)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutions -
50081903 (Belgium)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsfr -
50081905 (Slovakia)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutions -
50081902 (Russia)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsRussisch -
50081904 (France)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsfr -
50081904 (Austria)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsDuits -
50081902 (Austria)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsDuits -
50081903 (China)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsChinees -
50081903 (United Arab Emirates)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsEngels -
50081905 (Finland)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsFins -
50081905 (New Zealand)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsEngels -
50081904 (European Union)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsEngels -
50081904 (Germany)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsDuits -
50081902 (Turkey)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsTurks -
50081906 (Germany)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsDuits -
50081904 (New Zealand)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsEngels -
50081906 (Switzerland)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsDuits -
50081904 (India)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsEngels -
50081903 (Hungary)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsHongaars -
50081903 (Lithuania)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutions -
50081905 (Austria)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsDuits -
50081905 (China)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsChinees -
50081906 (Poland)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsPools -
50081904 (South Africa)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsEngels -
50081903 (Poland)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsPools -
50081903 (Greece)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsGrieks -
50081906 (France)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsfr -
50081905 (Spain)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsSpaans -
50081903 (Latvia)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutions -
50081904 (Australia)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsEngels -
50081902 (Spain)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsSpaans -
50081905 (Czech Republic)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsTsjechisch -
50081904 (Spain)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsSpaans -
50081905 (Greece)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsGrieks -
50081902 (USA)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsEngels -
50081904 (Norway)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsNoors -
50081905 (Lithuania)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutions -
50081902 (Finland)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsFins -
50081906 (Malta)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsEngels -
50081902 (France)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsfr -
50081903 (Denmark)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsDeens -
50081906 (United Kingdom)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsEngels -
50081903 (Portugal)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsPortugees -
50081904 (Latvia)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutions -
50081903 (Russia)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsRussisch -
50081904 (Denmark)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsDeens -
50081906 (European Union)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsEngels -
50081902 (India)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsEngels -
50081904 (Ireland)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsEngels -
50081902 (Germany)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsDuits -
50081902 (European Union)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsEngels -
50081902 (Sweden)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsZweeds -
50081903 (Switzerland)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsDuits -
50081906 (Latvia)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutions -
50081904 (Greece)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsGrieks -
50081906 (China)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsChinees -
50081903 (Germany)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsDuits -
50081904 (China)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsChinees -
50081906 (Greece)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsGrieks -
50081902 (Switzerland)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsDuits -
50081903 (Slovakia)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutions -
50081902 (Estonia)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutions -
50081905 (India)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsEngels -
50081902 (Latvia)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutions -
50081905 (Poland)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsPools -
50081902 (Norway)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsNoors -
50081904 (Ukraine)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutions -
50081905 (France)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsfr -
50081902 (Lithuania)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutions -
50081905 (Hungary)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsHongaars -
50081902 (Italy)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsItaliaans -
50081905 (Mexico)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsSpaans -
50081904 (USA)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsEngels -
50081903 (Italy)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsItaliaans -
50081902 (Czech Republic)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsTsjechisch -
50081906 (Finland)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsFins -
50081903 (South Africa)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsEngels -
50081905 (Denmark)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsDeens -
50081906 (Austria)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsDuits -
50081906 (South Africa)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsEngels -
50081903 (Croatia)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutions -
50081906 (Romania)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsRoemeens -
50081906 (Bulgaria)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsBulgaars -
50081906 (Estonia)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutions -
50081902 (Australia)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsEngels -
50081902 (Malta)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsEngels -
50081902 (South Africa)
CLY11-A Calibration solution, 74.0 µS/cm
Calibration solutionsEngels -
50081905 (Ukraine)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutions -
50081905 (Latvia)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutions -
50081905 (South Africa)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsEngels -
50081906 (Ukraine)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutions -
50081904 (Italy)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsItaliaans -
50081904 (Hungary)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutionsHongaars -
50081905 (Switzerland)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsDuits -
50081904 (Lithuania)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutions -
50081903 (Malta)
CLY11-B Calibration solution, 149.6 µS/cm
Calibration solutionsEngels -
50081905 (Bulgaria)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsBulgaars -
50081906 (India)
CLY11-E Calibration solution 107.00 mS/cm
Calibration solutionsEngels -
50081904 (Croatia)
CLY11-C Calibration solution 1.406 mS/cm
Calibration solutions -
50081905 (European Union)
CLY11-D Calibration solution 12.64 mS/cm
Calibration solutionsEngels -
Memosens
Productcode: CLS82D-
verklaring Number: HE_00358_01.16
Specificatie van de fabrikant: 10/2011, 1935/2004Manufacturer DeclarationDuits , Engels -
Memosens
Productcode: CLS82D-
verklaring Number: HE_00358_02.19
Specificatie van de fabrikant: 1935/2004Manufacturer DeclarationDuits , Engels -
Memosens
Productcode: CLS82D-
verklaring Number: HE_01107_01.19
Specificatie van de fabrikant: RoHSManufacturer DeclarationDuits , Engels -
Memosens
Productcode: CLS82D-
verklaring Number: HE_00412_01.17
Specificatie van de fabrikant: RoHSManufacturer DeclarationDuits , Engels -
Memosens
Productcode: CLS82D-
verklaring Number: FDA_00237_01.20FDA DeclarationDuits , Engels -
OxyMax W, OxyMax H, OrbiSint, OrbiPore, OrbiPac, Messkabel, Memosens, Liquiline, InduMax P, InduMax H, ConduMax W, ConduMax H, CeraLiquid, CeraGel
Productcode: CYK20-, CYK10-, CPS92D-, CPS72D-, CPS71D-, CPS42D-, CPS41D-, CPS31D-, CPS16D-, CPS12D-, CPS11D-, CPF82D-, COS81D-, COS51D-, COS22D-, COS21D-, CML18-, CLS82D-, CLS54D-, CLS50D-, CLS21D-, CLS16D-, CLS15D-
verklaring Number: EC_00828_01.20EU DeclarationDuits , Engels , fr -
Memosens
Productcode: CLS82D-
verklaring Number: EC_00383_02.16EU DeclarationDuits , Engels , fr -
Memosens
Productcode: CLS82D-
verklaring Number: EC_00382_02.16EU DeclarationDuits , Engels , fr -
Memosens
Productcode: CLS82D-
verklaring Number: EC_00383_01.16EU DeclarationDuits , Engels , fr -
SmarTec S, SmarTec, Sensor, Memosens, Liquisys Conductivity, Liquiline, InduMax P, InduMax H, ConduMax W, ConduMax H, Chloromax, ANALOG
Productcode: CLM253-, CLS12-, CLS13-, CLS15-, CLS15D-, CLS16-, CLS16D-, CLS19-, CLS21-, CLS21D-, CLS30-, CLS50-, CLS50D-, CLS54-, CLS54D-, CLS82D-, CYM290-, CLM223F-, CLM223-, CLD18-, CLD134-, CLD132-, CCS55D-, CCS51D-, CCS51-, CCS50D-, CCS50-, CCS241-, CCS240-, CCS142D-, CCS141-, CCS140-, CCS120D-, CCS120-
Regio: Russia (Declaration of Conformity)
Keurnummer: EAEC RU D-DE.AD07.B.01363/19MiscellaneousRussisch -
ConduMax H, ConduMax W, InduMax H, InduMax P, Liquisys Conductivity, Memosens, SmarTec, SmarTec S
Productcode: CLS82D-, CLS54D-, CLS54-, CLS50D-, CLS50-, CLS30-, CLS21D-, CLS21-, CLS19-, CLS16D-, CLS16-, CLS15D-, CLS15-, CLS13-, CLS12-, CLM253-, CLM223F-, CLM223-, CLD18-, CLD134-, CLD132-
Keurnummer: EAEC RU D-DE.AD.07.B.01362/19MiscellaneousRussisch -
TopHit, OxyMax W, OxyMax H, OrbiSint, OrbiPore, Messkabel, Memosens, Memocheck, ConduMax W, ConduMax H, Ceramax, CeraLiquid, CeraGel
Productcode: CYP02D-, CYP01D-, CYK20-, CYK10-, CPS96D-, CPS92D-, CPS91D-, CPS76D-, CPS72D-, CPS71D-, CPS491D-, CPS471D-, CPS441D-, CPS42D-, CPS41D-, CPS341D-, CPS171D-, CPS16D-, CPS12D-, CPS11D-, COS81D-, COS51D-, COS22D-, CLS82D-, CLS21D-, CLS16D-, CLS15D-
Regio: International (IECEx)
Keuringsinstantie: EXAM (DMT, BVS)Explosion ProtectionEngels -
TopHit, Sensor, OxyMax W, OxyMax H, OrbiTex, OrbiSint, OrbiPore, Memosens, Liquiline M, InduMax P, InduMax H, ConduMax W, ConduMax H, CeraLiquid, CeraGel
Productcode: CPS42-, CPS42D-, CPS43-, CPS441-, CPS441D-, CPS471-, CPS471D-, CPS491-, CPS491D-, CPS64-, CPS71-, CPS71D-, CPS72-, CPS72D-, CPS76D-, CPS91-, CPS91D-, CPS92D-, CPS96D-, CPS41D-, CPS41-, CPS21-, CPS16D-, CPS13-, CPS12D-, CPS12-, CPS11D-, CPS11-, COS81D-, COS51D-, COS22D-, CM42-, CLS82D-, CLS54-, CLS50D-, CLS50-, CLS21D-, CLS16D-, CLS15D-
Regio: Russia (TR CU)
Keuringsinstantie: EAC
Bescherming: Ex ia IIC T3 Ga, Ex ia IIC T4 Ga, Ex ia IIC T6 Ga, Ex ib [ia Ga] IIC T4 Gb, Ex ib [ia Ga] IIC T6 GbExplosion ProtectionRussisch -
TopHit, OxyMax W, OxyMax H, OrbiSint, OrbiPore, Memosens, ConduMax W, ConduMax H, Ceramax, CeraLiquid, CeraGel
Productcode: CPS96D-, CPS92D-, CPS91D-, CPS76D-, CPS72D-, CPS71D-, CPS491D-, CPS471D-, CPS441D-, CPS42D-, CPS41D-, CPS341D-, CPS171D-, CPS16D-, CPS12D-, CPS11D-, COS81D-, COS51D-, COS22D-, CLS82D-, CLS21D-, CLS16D-, CLS15D-
Regio: South Korea
Keuringsinstantie: KTL
Bescherming: Ex ia IIC T6...T3Explosion Protection -
TopHit, OxyMax W, OxyMax H, OrbiSint, OrbiPore, OrbiPac, Memosens, Liquiline, InduMax P, ConduMax W, ConduMax H, Chloromax, CeraLiquid, CeraGel
Productcode: CPF81D-, CPF82D-, CPS11D-, CPS12D-, CPS16D-, CPS171D-, CPS41D-, CPS42D-, CPS441D-, CPS471-, CPS471D-, CPS491-, CPS71D-, CPS72D-, CPS76D-, CPS91D-, CPS92D-, CPS96D-, COS81D-, CCS120D-, CCS142D-, CCS50D-, CCS51D-, CLS15D-, CLS16D-, CLS21D-, CLS50D-, CLS82D-, CM442-, CM442R-, CM444-, CM444R-, CM448-, CM448R-, COS21D-, COS22D-, COS51D-
Regio: Canada, USA
Keuringsinstantie: CSAExplosion ProtectionEngels -
OxyMax W, OxyMax H, OrbiSint, OrbiPore, Messkabel, Memosens, Memocheck, ConduMax W, ConduMax H, Ceramax, CeraLiquid, CeraGel
Productcode: CYP02D-, CYP01D-, CYK20-, CYK10-, CPS92D-, CPS91D-, CPS72D-, CPS71D-, CPS491D-, CPS471D-, CPS441D-, CPS42D-, CPS41D-, CPS341D-, CPS171D-, CPS12D-, CPS11D-, COS81D-, COS51D-, COS22D-, COS21D-, CLS82D-, CLS21D-, CLS16D-, CLS15D-
Regio: Europe (ATEX)
Keuringsinstantie: EXAM (DMT, BVS)Explosion ProtectionEngels -
TopHit, OxyMax W, OxyMax H, OrbiSint, OrbiPore, Messkabel, Memosens, Memocheck, ConduMax W, ConduMax H, Ceramax, CeraLiquid, CeraGel
Productcode: CYP02D-, CYP01D-, CYK20-, CYK10-, CPS96D-, CPS92D-, CPS91D-, CPS76D-, CPS72D-, CPS71D-, CPS491D-, CPS471D-, CPS441D-, CPS42D-, CLS15D-, CLS16D-, CLS21D-, CLS82D-, COS22D-, COS51D-, COS81D-, CPS11D-, CPS12D-, CPS16D-, CPS171D-, CPS31D-, CPS341D-, CPS41D-
Regio: International (IECEx)
Keuringsinstantie: EXAM (DMT, BVS)Explosion ProtectionEngels -
CeraLiquid, CeraGel, OxyMax W, OxyMax H, OrbiSint, OrbiPore, Messkabel, Memosens, Memocheck, ConduMax W, ConduMax H, Ceramax
Productcode: CYP02D-, CYP01D-, CYK20-, CYK10-, CPS92D-, CPS91D-, CPS72D-, CPS71D-, CPS491D-, CPS471D-, CPS441D-, CPS42D-, CPS41D-, CPS341D-, CPS171D-, CPS12D-, CPS11D-, COS51D-, COS22D-, COS21D-, CLS82D-, CLS21D-, CLS16D-, CLS15D-
Regio: Europe (ATEX)
Keuringsinstantie: EXAM (DMT, BVS)Explosion ProtectionDuits , Engels -
InduMax P, Liquiline M, Memosens
Productcode: CPS41-, CPS41D-, CPS42-, CPS42D-, CPS441-, CPS441D-, CPS471-, CPS471D-, CPS491-, CPS491D-, CPS64-, CPS71-, CPS71D-, CPS72-, CPS72D-, CPS76D-, CPS91-, CPS91D-, CPS92-, CPS92D-, CPS96D-, CTS1-, CYK10-, CYP01D-, CYP02D-, OPS171D-, CLS12-, CLS13-, CLS15-, CLS15D-, CLS16-, CLS16D-, CLS21-, CLS21D-, CLS50-, CLS50D-, CLS82D-, CM42-, COS21D-, CPS171D-, CPS16D-, CPS13-, CPS12D-, CPS12-, CPS11D-, CPS11-, CPF82D-, CPF82-, CPF81D-, CPF81-, COS51D-, COS22D-
Regio: USA
Keuringsinstantie: FMExplosion ProtectionEngels -
Memosens
Productcode: CLS82D-
Regio: China
Keuringsinstantie: NEPSIExplosion ProtectionEngels , Chinees -
TopHit, Memosens, InduMax P, OxyMax W, OxyMax H, OrbiSint, OrbiPore, OrbiPac, OEM, Messkabel, ConduMax W, ConduMax H, CeraLiquid, CeraGel
Productcode: CPS471D-, CLS50D-, COS22D-, CLS82D-, COS51D-, COS21D-, CPS491D-, CPS71D-, CPS72D-, CPS76D-, CPS91D-, CPS92D-, CPS96D-, CYK10-, CYK20-, OCLS82D-, OCOS81D-, OLS21D-, OPS11D-, OPS171D-, OPS91D-, OPS12D-, OYK10-, CPS441D-, CPS42D-, CPS41D-, CPS171D-, CPS16D-, CPS12D-, CPS11D-, CPF81D-, CPF82D-, COS81D-, CLS21D-, CLS16D-, CLS15D-
Regio: USA, Canada
Keuringsinstantie: CSAExplosion ProtectionEngels -
TopHit, OxyMax W, OxyMax H, OrbiSint, OrbiPore, Messkabel, Memosens, Memocheck, ConduMax W, ConduMax H, Ceramax, CeraLiquid, CeraGel
Productcode: CYP02D-, CYP01D-, CYK20-, CYK10-, CPS96D-, CPS92D-, CPS91D-, CPS76D-, CPS72D-, CPS71D-, CPS491D-, CPS471D-, CPS441D-, CLS15D-, CLS16D-, CLS21D-, CLS82D-, COS22D-, COS51D-, CPS11D-, CPS12D-, CPS16D-, CPS171D-, CPS341D-, CPS41D-, CPS42D-
Regio: International (IECEx)
Keuringsinstantie: EXAM (DMT, BVS)Explosion ProtectionEngels -
Memosens
Productcode: CLS82D-
Regio: Europe
Keuringsinstantie: TNOHygienic EquipmentEngels -
InduMax H, Memosens, SmarTec, SmarTec S, TopHit, UniFit H
Productcode: CPS77D-, CPS47D-, CPS471D-, CPS471-, CPS441D-, CPS441-, CPA842-, CLS82D-, CLS54D-, CLS54-, CLD18-, CLD134-, CPS61E-
Regio: USA
Keuringsinstantie: 3-A Sanitary StandardsHygienic EquipmentEngels -
Memosens
Productcode: CLS82D-, CLS82E-
Regio: Canada (CRN)Pressure EquipmentEngels -
Turbimax, TopHit, OxyMax W, OxyMax H, OrbiSint, OrbiPore, OrbiPac, New Analyzer Platform, Memosens, InduMax P, InduMax H, ConduMax W, ConduMax H, Chloromax, Ceramax, CeraLiquid, CeraGel
Productcode: CPS171D-, CPS31D-, CPS341D-, CPS41D-, CPS41E-, CPS42D-, CPS441D-, CPS471D-, CPS47D-, CPS491D-, CPS71D-, CPS71E-, CPS72D-, CPS76D-, CPS77D-, CPS91D-, CPS91E-, CPS92D-, CPS96D-, CPS97D-, CUS50D-, CUS51D-, CUS52D-, CA80HA-, CA80SI-, CCS120D-, CCS142D-, CCS50D-, CCS51D-, CLS15D-, CLS16D-, CLS21D-, CLS50D-, CLS54D-, CLS82D-, COS22D-, COS51D-, COS61D-, COS81D-, CPF81D-, CPF82D-, CPS11D-, CPS11E-, CPS12D-, CPS12E-, CPS16D-
Regio: Russia
Keurnummer: OC.C.31.004.A NO 75181MetrologyRussisch -
Viomax, New Analyzer Platform, Memosens, InduMax P, Turbimax, TopHit, Sample Preparations, OxyMax W, OxyMax H, OrbiSint, OrbiPore, OrbiPac, OEM, ConduMax W, InduMax H, ConduMax H, Chloromax, Ceramax, CeraLiquid, CeraGel
Productcode: CPS16D-, CAS51D-, CLS50D-, COS22D-, CLS82D-, CLS54D-, CAT860-, CA80AL-, COS51D-, CPS171D-, CPS31D-, CPS341D-, CPS41D-, CPS42D-, CPS441D-, CPS471D-, CPS491D-, CPS71D-, CPS72D-, CPS76D-, CPS91D-, CPS92D-, CUS50D-, CUS52D-, CPS12D-, CPS96D-, OCCS50D-, OCUS51D-, CPS11D-, CPF82D-, CPF81D-, COS81D-, COS61D-, CLS21D-, CLS16D-, CLS15D-, CCS142D-, CAT820-, CAT810-
Regio: Russia
Keuringsinstantie: Rosstandart
Keurnummer: DE.C.31.004.A NO 70194MetrologyRussisch -
SmarTec, Memosens, InduMax P, OxyMax W, OxyMax H, OrbiPac, Liquiline M, InduMax H, ConduMax W, ConduMax H
Productcode: CPS96D-, CM42-, CLS50D-, COS22D-, CLS82D-, CLS54D-, COS51D-, CLS54-, CLS52-, CPS76D-, CPS16D-, CPF82D-, CPF82-, CPF81D-, CPF81-, CLS50-, CLS30-, CLS16D-, CLS21D-, CLS21-, CLS15D-, CLS15-, CLS13-, CLS12-, CLD18-
Regio: Russia
Keuringsinstantie: Rosstandart
Keurnummer: OC.C.31.004.A NO 55929/1MetrologyRussisch -
Viomax, Turbimax, TopHit, OxyMax W, OxyMax H, OrbiSint, OrbiPore, OrbiPac, Memosens, Liquiline M, Liquiline, Isemax, InduMax P, InduMax H, ConduMax W, ConduMax H, Chloromax, Ceramax, CeraLiquid, CeraGel
Productcode: CPS47D-, CPS471D-, CPS441D-, CPS42D-, CPS41E-, CPS41D-, CPS341D-, CPS31D-, CPS171D-, CPS16D-, CPS12E-, CPS12D-, CPS11E-, CPS11D-, CPS491D-, CPS71D-, CPS71E-, CPS72D-, CPS76D-, CPS77D-, CPS91D-, CPS91E-, CPS92D-, CPS96D-, CPS97D-, CUS50D-, CUS51D-, CUS52D-, CAS40D-, CCS120D-, CCS142D-, CCS50D-, CCS51D-, CLS15D-, CLS15E-, CLS16D-, CLS16E-, CLS21D-, CLS21E-, CLS50D-, CLS54D-, CLS82D-, CLS82E-, CM14-, CM442-, CM442R-, CM444-, CM444R-, CM448-, CM448R-, COS22D-, COS51D-, COS61D-, COS81D-, CPF81D-, CPF82D-
Regio: Russia
Keuringsinstantie: Rosstandart
Keurnummer: OC.C.31.004.A NO 54218/1MetrologyRussisch -
Memosens
Productcode: CLS82D-
Regio: China
Keurnummer: 2017-C114MetrologyEngels -
ConduMax W, InduMax P, Memosens, OrbiPac, OrbiSint, OxyMax H, Turbimax
Productcode: CUS52D-, CUS50D-, CPS12D-, CPS11D-, CPF81D-, COS81D-, CLS82D-, CLS50D-, CLS21D-, CCS55D-, CCS51D-, CCS50D-
Regio: International
Keuringsinstantie: LRMarineEngels -
Turbimax, OxyMax H, OrbiSint, OrbiPac, Messkabel, Memosens, Liquiline, InduMax P, ConduMax W
Productcode: CYK10-, CUS52D-, CUS50D-, CPS12D-, CPS11D-, CPF81D-, COS81D-, CM82-, CM72-, CLS82D-, CLS50D-, CLS21D-, CCS55D-, CCS51D-, CCS50D-
Regio: International
Keuringsinstantie: ABSMarineEngels -
Turbimax, OxyMax H, OrbiSint, OrbiPac, Messkabel, Memosens, Liquiline M, Liquiline, InduMax P, ConduMax W
Productcode: CYK10-, CUS52D-, CUS50D-, CPS12D-, CPS11D-, CPF81D-, COS81D-, CM82-, CM72-, CLS82D-, CLS50D-, CLS21D-, CCS55D-, CCS51D-, CCS50D-
Regio: International
Keuringsinstantie: ABSMarineEngels -
Turbimax, OxyMax H, OrbiSint, OrbiPac, Memosens, InduMax P, ConduMax W
Productcode: CCS50D-, CCS51D-, CCS55D-, CLS21D-, CLS50D-, CLS82D-, COS81D-, CPF81D-, CPS11D-, CPS12D-, CUS50D-, CUS52D-
Regio: International
Keuringsinstantie: BVMarineEngels -
Turbimax, OxyMax H, OrbiSint, OrbiPac, Messkabel, Memosens, Liquiline M, Liquiline, InduMax P, ConduMax W
Productcode: CYK10-, CUS52D-, CUS50D-, CPS12D-, CPS11D-, CPF81D-, COS81D-, CM82-, CM72-, CLS82D-, CLS50D-, CLS21D-, CCS55D-, CCS51D-, CCS50D-
Regio: International
Keuringsinstantie: DNVGLMarineEngels
Accessoires / Spare parts
-
-
Nr A Order code 71307105
Kit CLS82D: Gaskets FPM, FDA
-
Nr A Order code 71307106
Kit CLS82D: Gaskets EPDM, FDA
-
Nr A Order code 71307107
Kit CLS82D: Gaskets Silicone, FDA
-
-
Voorganger