Conductivity transmitter
Liquisys CLM223
Compact panel device for all industries
Liquisys CLM223 is a standard transmitter for all analog conductivity sensors. It improves your operational safety thanks to continuous plausibility, process and sensor checks. Select from numerous hardware and software modules, such as relays or fieldbus communication, to adapt it exactly to your measuring task. This modularity also allows you to upgrade the transmitter at any time. A simple menu and calibration make configuration and operation fast and easy.
-
Eenvoudige producten
- Gemakkelijk te selecteren, installeren en gebruiken
Technische topkwaliteit
Eenvoud
-
Standaardproducten
- Betrouwbaar, robuust en onderhoudsarm
Technische topkwaliteit
Eenvoud
-
Gespecialiseerde producten
- Ontworpen voor veeleisende applicaties
Technische topkwaliteit
Eenvoud
Variabel
FLEX selectie | Technische topkwaliteit | Eenvoud |
---|---|---|
Fundamental selectie Voldoe aan uw basismeetvoorwaarden |
Technische topkwaliteit
|
Eenvoud
|
Lean selectie Beheers eenvoudig uw belangrijkste processen |
Technische topkwaliteit
|
Eenvoud
|
Extended selectie Optimaliseer uw processen met innovatieve technologieën |
Technische topkwaliteit
|
Eenvoud
|
Xpert selectie Beheers uw meest uitdagende applicaties |
Technische topkwaliteit
|
Eenvoud
Variabel |
-
Overzicht specificaties
-
Input
1-channel transmitter
-
Output
0/4-20 mA, Hart, Profibus.
-
Ingres protection
IP65
-
Snelle selectie
Individuele configuratie
-
Voordelen
More operational safety: Continuous process check system, customized alarm configuration, calibration plausibility check.
Broad functionality: Conductivity, resistivity and concentration measurement, ultrapure water monitoring according to USP and EP.
...
-
Toepassingsgebied
The Liquisys CLM223 transmitter works with all analog conductivity sensors in non-hazardous areas, for example in these industries and their utilities:
Chemicals
Food & Beverages
Life Sciences
Power &Energy
Water &Wastewater
Primaries & Metal
...
Documenten / handleidingen / software
-
Liquisys M CLM223/253
Technical Information
Transmitter for conductive and inductive sensors
Technische informatie (TI) -
Operating Instructions Liquisys M CLM223F
Transmitter for Conductivity
Inbedrijfsstellingsvoorschriften (BA) -
Operating Instructions Liquisys M CXM223/253 HART
Field Communication with Liquisys M CXM223/253
Inbedrijfsstellingsvoorschriften (BA) -
Liquisys M CLM223/253
Operating Instructions
Transmitter
Inbedrijfsstellingsvoorschriften (BA) -
Operating Instructions Liquisys M CXM223/253 PROFIBUS
Field Communikation for Liquisys M CXM223/253
Inbedrijfsstellingsvoorschriften (BA) -
Ex-safety instructions CXM2X3
Safety instructions for electrical apparatus for explosion-hazardous
areas as per EC Directive 94/9/EC (ATEX)Ex Veiligheidsinstructies (XA) -
Instructions for service kits Liquisis M
Special documentation
Instructions for service kits Liquisis M / CPM223 / CLM223 / COM223 /
CUM223Speciale Documentatie (SD) -
Additional information for CSA Liquisys
Additional information for CSA Liquisys
Speciale Documentatie (SD) -
Automatic control of disinfection
Field experience, absolute control of the chlorine and bisulphite
dosagesPublicaties (PU)11/07us -
Conductivity measurement in industrial processes
Selection and engineering guide for different industries and
applicationsCompetentie Brochure (CP)12/19Engels -
Leitfähigkeitsmessung in Industrieprozessen
Auswahl- und Engineeringhilfe für verschiedene Industrien und
AnwendungenCompetentie Brochure (CP)12/19Duits -
GSD Single, GSD_EH_DP_AN_Liquisys_0x1521_V02_04_DPLIB, 14.04.2014 (Analys
is, Liquisys M, 0x1521i)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.04.00Language neutral -
GSD Single, GSD_EH_PA_AN_Liquisys_0x1515_V02_30_PALIB, 22.04.2014 (Analys
is, Liquisys M, 0x1515i)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.03.00Language neutral -
GSD Single, GSD_EH_DP_AN_Liquisys_0x1521_V02_03_DPLIB, 14.04.2014 (Analys
is, Liquisys M, 0x1521c)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.03.00Language neutral -
GSD Single, GSD_EH_PA_AN_Liquisys_0x1515_V02_00_PALIB, 22.04.2014 (Analys
is, Liquisys M, 0x1515c)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.00.00Language neutral -
DTM Single, LiquisysM_CLM2x3ind_DP_V2_30___V2_31, 28.10.2020 (Analysis, Liquisys M, 0x1521i)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, LiquisysM_CLM2x3cond_DP_V2_30___V2_31, 28.10.2020 (Analysis, Liquisys M, 0x1521c)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, LiquisysM_CLM2x3ind_PA_V2_30___V2_31, 20.10.2020 (Analysis, Liquisys M, 0x1515i)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, LiquisysM_CLM2x3cond_PA_V2_30___V2_31, 20.10.2020 (Analysis, Liquisys M, 0x1515c)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, LiquisysMCond_I_CLM2x3_V2_30, 26.10.2020 (Analysis, Liquisys M, 0x0092)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, LiquisysMCond_C_CLM2x3_V2_30, 26.10.2020 (Analysis, Liquisys M, 0x0093)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
Measurement of electrical conductivity
(.mp4 format, 116 MB)
The conductivity of a liquid can be measured using the conductive or
toroidal measuring principles. This video shows what it is about and how
these measuring principles work.Animatie01/14Pools -
Measurement of electrical conductivity
(.mp4 format, 70,7MB)
The conductivity of a liquid can be measured using the conductive or
toroidal measuring principles. This video shows what it is about and how
these measuring principles work.Animatie01/14fr -
Liquisys Chlorine, Liquisys Conductivity, Liquisys Oxygen, Liquisys pH/ORP
Productcode: CCM223-, CCM253-, CLM223-, CLM253-, COM223-, COM253-, CPM223-, CPM253-
verklaring Number: EC_00575_01.17EU DeclarationDuits , Engels , fr -
SmarTec S, SmarTec, Sensor, Memosens, Liquisys Conductivity, Liquiline, InduMax P, InduMax H, ConduMax W, ConduMax H, Chloromax, ANALOG
Productcode: CLM253-, CLS12-, CLS13-, CLS15-, CLS15D-, CLS16-, CLS16D-, CLS19-, CLS21-, CLS21D-, CLS30-, CLS50-, CLS50D-, CLS54-, CLS54D-, CLS82D-, CYM290-, CLM223F-, CLM223-, CLD18-, CLD134-, CLD132-, CCS55D-, CCS51D-, CCS51-, CCS50D-, CCS50-, CCS241-, CCS240-, CCS142D-, CCS141-, CCS140-, CCS120D-, CCS120-
Regio: Russia (Declaration of Conformity)
Keurnummer: EAEC RU D-DE.AD07.B.01363/19MiscellaneousRussisch -
ConduMax H, ConduMax W, InduMax H, InduMax P, Liquisys Conductivity, Memosens, SmarTec, SmarTec S
Productcode: CLS82D-, CLS54D-, CLS54-, CLS50D-, CLS50-, CLS30-, CLS21D-, CLS21-, CLS19-, CLS16D-, CLS16-, CLS15D-, CLS15-, CLS13-, CLS12-, CLM253-, CLM223F-, CLM223-, CLD18-, CLD134-, CLD132-
Keurnummer: EAEC RU D-DE.AD.07.B.01362/19MiscellaneousRussisch -
ConduMax H, ConduMax W, InduMax H, InduMax P, Liquisys Conductivity, SmarTec S
Productcode: CLS54-, CLS52-, CLS50-, CLS30-, CLS21-, CLS19-, CLS16-, CLS15-, CLS13-, CLS12-, CLM253-, CLM223-, CLD134-, CLD132-
Regio: Russia
Keuringsinstantie: Rosstandart
Keurnummer: DE.C.31.004.A_66843MetrologyRussisch -
Liquisys Chlorine, Liquisys Conductivity, LIQUISYS M, Liquisys Oxygen, Liquisys Turbidity, SmarTec S
Productcode: CUM253-, CUM223-, CPM253-, CPM223-, COM253F-, COM253-, COM223F-, COM223-, CLM253-, CLM223F-, CLM223-, CLD134-, CCM253-, CCM223-
Regio: Canada, USA
Keuringsinstantie: CSAOrdinary Location Product SafetyEngels
Accessoires / Spare parts
-
-
Nr 290 Order code 51511446
KIT CXM2X3 relay mod. 2rel / CSA
Upgrade van LIQUISYS-M basis versie door 2 potentiaalvrije wisselcontacten.
-
-
-
Order code 51500320
CxM2x3 relaismodule (2 relais)
Upgrade of LIQUISYS-M basis versie 2 potentiaal vrije wissel contacten
-
-
-
Nr 300 Order code 51500321
CxM2x3 4 RELAISPRINT MET CHEMOCLEAN
Let op Fabriek heeft serienummer nodig !
-
Nr 300 Order code 71129943
Kit CxM2x3: realy modul 4 REL prot. coat
Upgrade of basic function of LIQUISYS-M with 4 dry changeover contacts eletronics with protection coating
-
Nr 300 Order code 51511447
KIT CXM2X3 relay mod. 4rel / CSA
-
-
-
Nr 290 Order code 51504304
2-relaiskaart met stroomingang 4-20mA
Upgrade van Liquisys M in basisversie met 2 contacten en stroomingang 4-20 mA
-
-
-
Nr 300 Order code 51504305
4 relaisprint met stroomingang 4-20 mA
Upgrade van Liquisys M basis versie met 4 relais en stroomingang 4-20 mA
-
-
-
Nr 15 Order code 51500317
CxM2x3 voeding AC
-
Nr 15 Order code 71129939
KIT CXM2X3 power supply AC prot.coating
CxM2x3 power supply 100/115/230 V AC eletronics with protection coating
-
-
-
Nr 20 Order code 51500318
-
-
-
Nr 330 Order code 51501075
CCM223 behuizing kompleet
-
-
-
Order code 51501076
CCM223 achter- en zijwand.
-
-
-
Nr 310 Order code 51502124
CXM223 Zijwand (10 stuks)
-
-
-
Nr 340 Order code 51502513
CXM223 aansluitraam achterkant Profib.DP
-
-
-
Nr 345 Order code 51501086
CxM223 Klemmenset vereffeningsklem
-
-
-
Nr 430 Order code 51501078
CxM2x3 aansluitklem voor uitgangsrelais
-
-
-
Nr 40 Order code 51501210
CLM2X3 centrale mod. conductief 1 I
-
-
-
Nr 60 Order code 51501213
CLM2X3 centrale mod.conductief 1I+HART
-
-
-
Nr 50 Order code 51501212
CLM2x3 Centrale mod. conductief 2 I
-
-
-
Nr 70 Order code 51501214
CLM2X3 centrale mod. conductief 2I+HART
-
-
-
Nr 80 Order code 51501215
CLM2x3 hoofdprint conductief Profi PA
-
-
-
Nr 90 Order code 51502502
CLM2X3 Centraalmodu ProfibusDPConductief
-
Nr 90 Order code 71134726
Kit CLM2x3: Centralm. cond. PBDP;H/W2.1x
Inhoud: 1x Centrale module Profibus DP Module naam: LSCP-DP qualifired van H / W 2,10
-
-
-
Nr 290 Order code 71134732
Kit CxM2x3: Relay mod. for PBDP; H/W2.1x
Inhoud: 1x Relaismodule Profibus DP 2x relais, 1x Stroomingang DP- aansluiting gekwalificeerd vanaf H/W 2,10
-
-
-
Nr 40 Order code 51501216
CLM2X3 centrale mod. inductief 1 I
-
-
-
Nr 60 Order code 51501219
CLM2X3 centrale mod. conductief 1I+HART
-
-
-
Nr 50 Order code 51501218
CLM223 centraalmodule 2 stroom z. HART
-
-
-
Nr 70 Order code 51501220
CLM223 induktieve module I2 HART
-
-
-
Nr 80 Order code 51501221
CLM2x3 hoofdprint induktief Profi PA
-
-
-
Nr 90 Order code 51502501
CLM2X3 Centraalmodu ProfibusDP induktief
-
Nr 90 Order code 71134727
Kit CLM2x3: Centralm. ind. PBDP; H/W2.1x
Inhoud: 1x Centrale module Profibus DP Module naam: LSCP-DP qulaifired van H/W 2,10
-
-
-
Nr 420 Order code 51501203
CLM 223 klemmenset (niet voor PA/DP!)
-
Nr 420 Order code 51502126
CLM223 klemmenstrook Profibus PA
-
Nr 420 Order code 51502493
Kit CLM223 terminal strip, Profibus DP
-
-
-
Nr 335 Order code 71071440
Kit CxM223: front foil + 6 key lifters
-
-
-
Order code 51500385
CxM2x3 PLUSPAKKET KIT
Upgrade of LIQUISYS-M basic version (parameter pH,Cond.,Tu,CL,O2 (WX to WS)) to S-version (plus-package). Serial number of instrument needed.
-
Order code 51500963
UPGRADE CLEANING VOOR LIQUISYS-M
Upgrade of LIQUISYS-M basic version by cleaning functionality (Chemoclean) (serial number of instrument needed). If not yet installed, a 4-relay board must be ordered separately (51500321).
-
-
-
Nr 240 Order code 71161133
Kit: MKIC Conductiv. transmitter Non-Ex
-
-
-
Order code 50047795
CXM 121 bevestigingsklem.
-
-
Voorganger