Overzicht specificaties
-
Input
1 to 2x Memosens digital input
2x 0/4 to 20mA Input optional
2x Digital input optional -
Output / communication
2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay, ProfibusDP, Modbus RS485,
Modbus TCP, Ethernet -
Ingres protection
Transmitter: IP20
Optional Display: IP66
Toepassingsgebied
Liquiline CM442R allows you to connect up to 2 Memosens sensors of your choice from over 12 measurement parameters. With its extremely compact design, it fits into any cabinet - and even offers inputs, outputs, controllers, and math modules, e.g. for cleaning control. The transmitter belongs to the Liquiline platform with standardized system integration, operation, and spare parts. Heartbeat Technology helps you find the ideal balance between measurement point availability and maintenance costs.
Liquiline CM442R is suitable for all industries and their utilities, such as:
Food & Beverages
Life Sciences
Power & Energy
Water & Wastewater
Chemicals
Marine
It features the following communication protocols and interfaces:
0/4...20 mA
HART
PROFIBUS DP
Modbus RS485/RTU
Modbus TCP
EtherNet/IP
PROFINET
Webserver
The transmitter can be extended with a module whose explosion protection approvals, such as IECEx, ATEX and CSA, allow the connection of sensors installed in hazardous areas.
Voordelen
Saves space, saves money:
Extremely small footprint, saves space in cabinets – perfect for skids.High-speed installation:
No cut-out in cabinet door, one-click DIN-rail mounting, minimized wiring.Simple and safe commissioning:
Saving configuration on SD card enables fast set-up on duplicate installations.Easy to operate and service:
Intuitive user interface, hot plug & play with pre-calibrated Memosens sensors, universal components fit all parameters.Process control from a distance:
Integrated web server that allows the operator to remotely view diagnostic data, perform configurations, or access device parameters in any web browser - even via Smartphone.Higher availability, lower costs:
Heartbeat Technology enables status-oriented maintenance and easy verification of the entire measuring point and helps to carry out optimization measures.
Video's
Extended selectie
-
High-end producten
- Functioneel en uiterst doelmatig
Technische topkwaliteit
Eenvoud

-
Eenvoudige producten
- Gemakkelijk te selecteren, installeren en gebruiken
Technische topkwaliteit
Eenvoud
-
Standaardproducten
- Betrouwbaar, robuust en onderhoudsarm
Technische topkwaliteit
Eenvoud
-
Gespecialiseerde producten
- Ontworpen voor veeleisende applicaties
Technische topkwaliteit
Eenvoud
Variabel
FLEX selectie | Technische topkwaliteit | Eenvoud |
---|---|---|
Fundamental selectie Voldoe aan uw basismeetvoorwaarden |
Technische topkwaliteit
|
Eenvoud
|
Lean selectie Beheers eenvoudig uw belangrijkste processen |
Technische topkwaliteit
|
Eenvoud
|
Extended selectie Optimaliseer uw processen met innovatieve technologieën |
Technische topkwaliteit
|
Eenvoud
|
Xpert selectie Beheers uw meest uitdagende applicaties |
Technische topkwaliteit
|
Eenvoud
Variabel |
-
-
Operating Instruction (BA)
Liquiline CM44x/CM44xR Manuel de mise en service
Franse versie - 06/2013
Contrôleur multivoie 4 fils universel Configuration & réglages
EN NL 26/06/201325/03/201301/08/201215/12/201115/12/2010Taal:
French
Versie:
26/06/2013
Bestandsgrootte:
6.8 MB
Bestandsnaam:
BA00450CFR_1713.pdf
-
-
-
Technische informatie (TI)
Liquiline CM442R/CM444R/CM448R
Cabinet controller with a maximum of eightmeasuring channels based on digital Memosens technology
EN NL 03/05/202211/05/202028/02/201913/06/201830/06/2017Taal:
Engels
Versie:
03/05/2022
Bestandsgrootte:
6.7 MB
Bestandsnaam:
TI01112CEN_1022-00.pdf
-
-
-
Operating Instruction (BA)
Inbedrijfstellingsvoorschrift CM44xR
Inbedrijfstelling
EN NL 08/10/202120/04/202127/01/202028/02/201930/05/2018Taal:
Nederlands
Versie:
27/06/2013
Bestandsgrootte:
5.3 MB
Bestandsnaam:
BA01225CNL_0113.pdf
-
-
-
Operating Instruction (BA)
Memosens
Sensor inputs with Memosens protocol
EN NL 30/05/202228/02/2019Taal:
Engels
Versie:
30/05/2022
Bestandsgrootte:
3.3 MB
Bestandsnaam:
BA01245CEN_0822-00.pdf
-
-
-
Operating Instruction (BA)
Operating Instructions CM44x/CM44xR
Operation and settings
EN NL 26/06/201325/03/201301/08/201215/12/201115/12/2010Taal:
Engels
Versie:
26/06/2013
Bestandsgrootte:
6.8 MB
Bestandsnaam:
BA00450CEN_1713.pdf
-
-
-
Operating Instruction (BA)
Operating Instructions CM442R/444R/448R
Maintenance & Diagnosis
EN NL 27/06/2013Taal:
Engels
Versie:
27/06/2013
Bestandsgrootte:
2.4 MB
Bestandsnaam:
BA01227CEN_0113.pdf
-
-
-
Short Instruction (KA)
Liquiline CM442R/CM444R/CM448R
Universele vierdraads multikanaal transmitter voor kastinstallatie
EN NL 08/10/202120/04/202130/11/201930/05/201830/04/2018Taal:
Nederlands
Versie:
20/04/2021
Bestandsgrootte:
3.4 MB
Bestandsnaam:
KA01160CNL_0821.pdf
-
-
-
Montage-instructies (EA)
Installation Instructions Kit CM44xR
External Display
EN NL 27/06/2013Taal:
Engels
Versie:
27/06/2013
Bestandsgrootte:
1.1 MB
Bestandsnaam:
EA01080CA2_0113.pdf
-
-
-
Montage-instructies (EA)
Installation Instructions Liquiline CM44xR
Service display for rail mounted device
EN NL 06/03/2014Taal:
Engels
Versie:
06/03/2014
Bestandsgrootte:
138.3 KB
Bestandsnaam:
EA01100CA2_0113.pdf
-
-
-
Montage-instructies (EA)
SD card kit
32 GB, industrial flash drive
EN NL 23/03/2021Taal:
Engels
Versie:
23/03/2021
Bestandsgrootte:
506.7 KB
Bestandsnaam:
EA01354CEN_0121.pdf
-
-
-
Montage-instructies (EA)
SD card kit
Industrial flash drive, 1 GB With firmware, no. 71127100 Without firmware, no. 71110815
EN NL 23/03/202109/10/202020/03/201725/06/201401/07/2012Taal:
Engels
Versie:
23/03/2021
Bestandsgrootte:
506.9 KB
Bestandsnaam:
EA00011CEN_0621.pdf
-