Overzicht specificaties
-
Measurement range
10 to 500 µg/l NO2-N
0.2 to 3.0 mg/l NO2-N
0.1 to 1.0 mg/l NO2-N
0.1 to 1.0 mg/l with dilution function to maximum 5 to 50 mg/l NO2-N -
Process temperature
4 to 40 °C (39 to 104 °F)
-
Process pressure
At atmospheric pressure, < 0.2 bar absolute
Toepassingsgebied
Liquiline System CA80NO offers precise, regulation-compliant online measurement of nitrite. It supports you in meeting the specified limits in drinking water, mineral water or food production. Like all Liquiline System analyzers, it enables plug & play of up to four Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning and the low reagent consumption reduce operating and maintenance costs. Advanced diagnostics with remote access ensure process safety.
Liquiline System CA80NO supports you in keeping the strict nitrite limits for:
Drinking water
Mineral water
Raw water for food production
Voordelen
Compliance with standard colorimetric measuring principle - naphthylamine method - following ISO 6777 and DIN EN 26777 ensures comparability to lab measurements.
Reduced operating costs through automatic calibration and cleaning.
Simple maintenance: no tools required.
Advanced diagnostics with remote access for increased process safety.
Fast commissioning and plug & play thanks to Memosens technology and user-friendly operation.
Easy upgrade of functionality - even to a complete measuring station - simply by adding modules and connecting Memosens sensors. Reduces installation effort.
Video's
Extended selectie
-
High-end producten
- Functioneel en uiterst doelmatig
Technische topkwaliteit
Eenvoud

-
Eenvoudige producten
- Gemakkelijk te selecteren, installeren en gebruiken
Technische topkwaliteit
Eenvoud
-
Standaardproducten
- Betrouwbaar, robuust en onderhoudsarm
Technische topkwaliteit
Eenvoud
-
Gespecialiseerde producten
- Ontworpen voor veeleisende applicaties
Technische topkwaliteit
Eenvoud
Variabel
FLEX selectie | Technische topkwaliteit | Eenvoud |
---|---|---|
Fundamental selectie Voldoe aan uw basismeetvoorwaarden |
Technische topkwaliteit
|
Eenvoud
|
Lean selectie Beheers eenvoudig uw belangrijkste processen |
Technische topkwaliteit
|
Eenvoud
|
Extended selectie Optimaliseer uw processen met innovatieve technologieën |
Technische topkwaliteit
|
Eenvoud
|
Xpert selectie Beheers uw meest uitdagende applicaties |
Technische topkwaliteit
|
Eenvoud
Variabel |
Voorganger
-
-
Technische informatie (TI)
Liquiline System CA80NO
Colorimetric analyzer for nitrite
EN NL 30/11/202213/07/202114/02/202009/06/201715/03/2016Taal:
Engels
Versie:
30/11/2022
Bestandsgrootte:
4.2 MB
Bestandsnaam:
TI01258CEN_0622-00.pdf
-
-
-
Bedieningshandleiding (BA)
Memosens
Sensor inputs with Memosens protocol
EN NL 30/05/202228/02/2019Taal:
Engels
Versie:
30/05/2022
Bestandsgrootte:
3.3 MB
Bestandsnaam:
BA01245CEN_0822-00.pdf
-
-
-
Bedieningshandleiding (BA)
Liquiline System CA80NO
Colorimetric analyzer for nitrite
EN NL 30/11/202213/07/202113/01/202009/06/201715/03/2016Taal:
Engels
Versie:
30/11/2022
Bestandsgrootte:
6.7 MB
Bestandsnaam:
BA01574CEN_0622-00.pdf
-
-
-
Beknopte instructie (KA)
Liquiline System CA80NO
Colorimetrische analyzer voor nitriet
EN NL 31/05/202119/02/202006/10/201707/04/201701/02/2016Taal:
Nederlands
Versie:
31/05/2021
Bestandsgrootte:
3.3 MB
Bestandsnaam:
KA01222CNL_0621.pdf
-
-
-
Montage-instructies (EA)
Kit CM44x/CSXxx/CA80XX
Module 485MB or 485DP For Ethernet configuration,PROFIBUS DP, Modbus RS485
EN NL 28/11/2022Taal:
Engels
Versie:
28/11/2022
Bestandsgrootte:
1.8 MB
Bestandsnaam:
EA01447CEN_0122-00.pdf
-
-
-
Montage-instructies (EA)
Kit CA80 Outdoor
Kit for mounting analyzer on a post outdoor
EN NL 14/02/2020Taal:
Engels
Versie:
14/02/2020
Bestandsgrootte:
414.2 KB
Bestandsnaam:
EA01293CEN_0119.pdf
-
-
-
Speciale documentatie (SD)
CM44x/R/P / CSFxx / CA80xx
Webserver Guideline
EN NL 27/01/202014/08/201928/07/201710/05/2013Taal:
Engels
Versie:
27/01/2020
Bestandsgrootte:
879 KB
Bestandsnaam:
SD01190CEN_04.20.pdf
-
-
-
Speciale documentatie (SD)
Liquiline CM44x, Liquiline CM44xR, Liquiline CM44P, Liquiline System CA80xx, Liquistation CSFxx
Data transmission via PROFINET
EN NL 09/06/202214/10/2019Taal:
Engels
Versie:
09/06/2022
Bestandsgrootte:
2.6 MB
Bestandsnaam:
SD02490CEN_02.22.pdf
-
-
-
Speciale documentatie (SD)
CM44x/R/P / CSFxx / CA80xx
PROFIBUS Guideline
EN NL 09/06/202227/01/202014/08/201908/09/201727/02/2014Taal:
Engels
Versie:
09/06/2022
Bestandsgrootte:
1.9 MB
Bestandsnaam:
SD01188CEN_06.22.pdf
-
-
-
Speciale documentatie (SD)
Activation codes kit
For extended functionality
EN NL 04/05/202003/05/201816/09/201424/03/201425/03/2013Taal:
Engels
Versie:
04/05/2020
Bestandsgrootte:
102.9 KB
Bestandsnaam:
SD00166CEN_0620.pdf
-