Voer tenminste 2 karakters in om het zoeken te starten.
  • Geschiedenis

Hydrostatic
Level measurement
Deltapilot FMB70

Deltapilot FMB70 hygienic housing ©Endress+Hauser
Deltapilot FMB70 aluminum housing ©Endress+Hauser
Deltapilot FMB70 separate housing ©Endress+Hauser
Deltapilot FMB70 separate housing hygienic ©Endress+Hauser

Pressure measuring principle

Deltapilot FMB70 ©Endress+Hauser

Highest performance pressure sensor with the Contite cell for hydrostatic level measurement

The Deltapilot FMB70 with the condensate resistant Contite measuring cell and two-chamber housing is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. The integrated HistoROM/M-DAT data module makes management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety systems.

Snelle selectie

Kies uit één van de voorgestelde opties
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

of

Individuele configuratie

Ga verder met uw keuze uit alle mogelijke opties
  • Voordelen

    • Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.1%, optionally ±0.075% and minimum temperature effects thanks to active temperature compensation

    • Best batch-to-batch repeatability and long-term stability

    • ...

  • Toepassingsgebied

    For level and/or pressure measurement.

    • Process connections: Threads, flanges and hygienic connections

    • Temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)

    • Measuring range: 0.1 to 10 bar rel. (1.5 to 150 psi)

    • Accuracy: ±0.075%

    • International...

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Hydrostatic pressure

  • Characteristic

    Pressure transmitter for pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
    - hermetically welded
    - absolute condensation tight
    - climate-resitant
    - long-term stable
    - Lowest temperature influences

    Compact version
    Modular Deviceplatform

  • Supply voltage

    4...20 mA HART

    10,5...45 VDC (Non Ex):

    Ex ia: 10,5...30 VDC

    PROFIBUS PA:

    9...32 VDC (Non Ex)

    FOUNDATION Fieldbus:

    9...32 VDC (Non Ex)

  • Reference Accuracy

    Standard 0,1%
    Optional 0,075%

  • Long term stability

    0,05% of URL/year

  • Process temperature

    -10°C...100°C
    (14°F...212°F)

  • Ambient temperature

    -40°C...85°C
    (-40°F...185°F)

  • Measuring cell

    100 mbar...10 bar
    (1.5 psi...150 psi)

  • Smallest calibratable span

    25 mbar (3.63 psi)

  • Vacuum resistance

    0 mbar abs.

  • Max. overpressure limit

    40 bar (600 psi)

  • Process connection

    Thread:

    G1 1/2, MNPT1/2

    Flange:

    DN40...DN100,

    ASME 1 1/2"...4",

    JIS 10K

  • Process connection hygienic

    Tri-Clamp

    DIN11851

    DIN11864-1

    NEUMO

    Varivent N

    SMS

    DRD

  • Material process membrane

    316L, AlloyC,

    Gold-Rhodium

  • Material gasket

    None, measuring cell welded

  • Fill fluid

    Inert oil,

    Synthetic oil

  • Material housing

    316L, Die-cast aluminum

  • Communication

    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC

  • Safety approvals

    SIL

  • Design approvals

    EN10204-3.1

    NACE MR0175
    MR0103

  • Hygienic approvals

    3A, EHEDG

    CoC ASME-BPE

  • Marine approvals

    GL, DNV

  • Drinking water approvals

    NSF

  • Specialities

    Gold-rhodium coated membrane

  • Meetprincipe

    Hydrostatic

  • Characteristic / Application

    Pressure transmitter for pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
    - hermetically welded
    - absolute condensation tight
    - climate-resitant
    - long-term stable
    - Lowest temperature influences

    Compact version
    Modular Deviceplatform

  • Specialities

    Diagnostic functions

  • Supply / Communication

    4...20mA HART:
    10,5...45V DC
    Ex ia: 10,5...30V DC
    PROFIBUS PA /
    FOUNDATION Fieldbus:
    9...32V DC (Non Ex)

  • Accuracy

    Standard 0,1%
    Optional 0,075%

  • Long term stability

    0,05% of URL/year

  • Ambient temperature

    -40°C...85°C
    (-40°F...185°F)

  • Process temperature

    -10°C...100°C
    (14°F...212°F)

  • Process pressure absolute / max. overpressure limit

    40 bar (600 psi)

  • Pressure measuring range

    100mbar...10bar
    (1.5psi...150psi)

  • Main wetted parts

    Alloy C
    316L

  • Process connection

    Thread:

    G1 1/2, MNPT1/2

    Flange:

    DN40...DN100,

    ASME 1 1/2"...4",

    JIS 10K

  • Process connection hygienic

    Tri-Clamp

    DIN11851

    DIN11864-1

    NEUMO

    Varivent N

    SMS

    DRD

  • Max. measurement distance

    100m (328ft) H2O

  • Communication

    4...20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC

  • Safety approvals

    SIL

  • Design approvals

    EN10204-3.1

    NACE MR0175, MR0103

  • Hygienic approvals

    3A, EHEDG

    CoC ASME-BPE

  • Marine approval

    GL/ DNV

  • Drinking water approvals

    NSF

  • Options

    HistoROM/M-Dat
    4-line digital display
    SS- or Aluminiumhousing

    Separate housing

  • Application limits

    Measuring cell: Contite,
    condensate-proof, watertight,
    metal welded

    If pressurized, possibly use
    differential pressure measurement
    with two pressure
    transmitters. Observe ratio
    head pressure : hydrostatic
    pressure

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
  • 12
    • Nr 12 Order code 52020440

      Montageset behuizing T14/T15 sensor

      Bestaat uit: 2x O-ring 45.69x2.62 EPDM. Borgring, kunststof. Gebruik: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 12 Order code 71020596

      Mounting set housing T17 / sensor

      Bestaat uit: 2x O-ring 45,62x69x2,62 EPDM. 1x profielpakking 51.4x57.2x1.6 EPDM. Behoudring, kunststof. Gebruik: FMB70, FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

  • 13
    • Nr 13 Order code 52022418

      DELTABAR S(7X) 2 BEDIENINGS TOETSEN V2.0

      Bestaat uit: drukknop, deksel + schroeven. Gebruik: externe werking, FMB70, FMD76/FMD77/FMD78,PMC71, PMD70/PMD75,PMP71/PMP75.

    • Nr 13 Order code 52024110

      DELTABAR S (7X) 3 BEDIENINGSTOETSEN V2.0

      Bestaat uit: Drukknop, deksel + schroeven. Kleur donkergrijs. Gebruik: externe werking, FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75.

  • 15
    • Nr 15 Order code 52020760

      Wartel M20x1.5, gasket

      Bestaat uit: Kabelwartel M20. O-ring 18.72x2.62 VMQ. Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Nr 15 Order code 52020761

      Cable entry G1/2, gasket, adapter

      Bestaat uit: Pakking 18,72x2,51 NBR. Adapter M20> G1/2. O-ring 18,77x1,78 NBR. Gebruik: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 15 Order code 52020762

      Plug 2/7-pole, HAN7D, gasket

      Bestaat uit: harting plug set. Gebruik: FMB50/FMB51/FMB52/FMB53, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD55, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Nr 15 Order code 52020763

      Plug 3-pole, M12, gasket

      Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Order code 52006263

      M12-female plug connector, cable side

      M12-connectoraansluiting, kabelzijde. Zelfconfigureerbare verbinding. Toepassing: FMB50/FMB51/FMB52/FMB53, FMB70, FTL31/FTL33, FTW23, FTW33,PMP11, PMP21, PMP51, PTC31B, PTP31B, QMW43. Dit betreft een product uit het E-direct portfolio met een scherpe netto prijs. Kijk voor meer informatie op www.e-direct.endress.com

    • Order code 71043576

      Set behuizing filter T14/T15, 3 stuks

      Bestaat uit: Filter plug, Gore-Tex filter. Gebruik: Behuizing T14, PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB70. Gebruik: Behuizing T15, FMB70.

    • Order code 71111056

      Housing filter VA,EPDM,F15/31/T14/17,1pc

      Bestaat uit: Vent schroef 304, compensatie druk filter, O-ring EPDM, dekseltje. Gebruik: Huisvesting T14, PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMD72. Behuizing F31, FMB50/51/52/53, PMC51, PMP51/PMP55. Behuizing F15 w / o B1, BB, BD, BF, GA, ID, I1, FMB50/51/52/53, PMC51, PMP51/PMP55.

    • Order code 71219639

      Housing filter VA, VMQ, F15, T17, 1 pc.

      Bestaat uit: Vent schroef 304, compensatie druk filter, O-ring VMQ, dekseltje. Usage: Huisvesting T17, PMC71, PMP71 / PMP75, PMD70/PMD75, FMD76/FMD77/FMD78. Huisvesting F15 voor B1, BB, BD, BF, GA, ID, I1, FMB50/51/52/53, PMC51, PMP51/PMP55.

  • 20
    • Nr 20 Order code 52020432

      Deksel T14/T15 Alu, dichting

      Materiaal: aluminium, gecoat. O-ring EPDM, FDA. Niet voor EEx d/XP. Gebruik: FMB70,FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 25
    • Nr 25 Order code 71002774

      Deksel T17 316L, pakking

      Materiaal: 316L. Vlakke pakking EPDM, centreer ring, schroef. Niet voor EEx d/XP. Gebruik: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 20
    • Nr 20 Order code 71002810

      Cover T17 316L, sight glass, gasket

      Materiaal: 316L. Kijkglas: mineraalglas. Platte pakking EPDM, centrerende ring, schroef. Voor goedkeuring 2,3,4,7,8, Q, W. Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75. Voor goedkeuring BC, BD,IB. Gebruik: FMD71/FMD72.

    • Nr 20 Order code 71002811

      Deksel T17 316L, met venster PC, o-ring

      Materiaal: 316L. Kijkglas: Polycarbonaat PC. Platte pakking EPDM, centrerende ring, schroef. Voor goedkeuring A,E,F,H,I,R,S,U,1,6. Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75. Voor goedkeuring AA,BA,CA,CB,CC,CD,FA, FB,FD,IA. Gebruik: FMD71/FMD72.

    • Nr 20 Order code 71245247

      Cover T14/T15 Alu, sight glass, gasket

      Material: Aluminium, coated. Sight glass Mineral glass, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMD71/FMD72, FMB70.

  • 21
    • Nr 21 Order code 52020429

      Dichtingsset EPDM, deksel T14, 5 stuks

      Bestaat uit: 5x O-ring 75,87x2.62, EPDM,PTFE,FDA. Gebruik: Huisvesting 30/F31/F34,T14/T15.

    • Order code 71290825

      Ground terminal T14/T15/T17, F30/F31

      Consists of: spring washer, screw, earth handle, clamp. Usage: PMC71, PMP71/PMP75, PMD70/PMD75, FMD71/FMD72, FMD77/FMD78, FMB70,housing T14/T15/T17. PMC51, PMP51/PMP55, FMB50/FMB51/FMB52/FMB53, PMD55, housing F30/F31.

  • 25
    • Nr 25 Order code 52020432

      Deksel T14/T15 Alu, dichting

      Materiaal: aluminium, gecoat. O-ring EPDM, FDA. Niet voor EEx d/XP. Gebruik: FMB70,FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 30
    • Nr 30 Order code 71026358

      FMB70 electr. bediening op elektronika

      4-20mA, version 02.10.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71026359

      Electronics HART Ex, ext. p. b., v2.10

      4-20mA, versie 02.10.zz. Drukknop op de behuizing. Gebruik: FMB70, FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Nr 30 Order code 71071824

      Elektronica PA, HW02.00, SW4.0

      PROFIBUS PA, Ex. Hardware versie 02.00. Software versie 04.00.zz. Huidig verbruik 13mA + / - 1 mA. Drukknop op elektronica. Usage: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB70.

    • Nr 30 Order code 71071825

      Electronics PA, ext. p. b.,HW02.00,SW4.0

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071826

      Electronics FF, HW02.00, SW3.0

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on electronics. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071827

      Electronics FF, ext. p. b.,HW02.00,SW3.0

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on housing. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71196092

      Electronic HART Ex, v2.11

      4-20mA, versie 02.11.zz. Druk op de knop op elektronica. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78,FMB70. Niet voor MID delen certificaat (PMP71).

    • Nr 30 Order code 71196093

      Electronics HART Ex, ext. p. b., v2.11

      4-20mA, versie 2.11.zz. Druk op de knop op de behuizing. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB70. Niet voor MID delen certificaat (PMP71).

    • Nr 30 Order code 71214890

      Electronics FF, ext. p.b.,HW2.00, SW4.00

      FOUNDATION Fieldbus, Ex. Hardware-versie 02.00. software versie 04.00.zz, FF, DevRev07. Stroomverbruik 15mA +/- 1 mA. Druk op de knop op de behuizing. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB70. Niet voor mariene certificaat en SIL.

    • Nr 30 Order code 71214892

      Electronics FF, HW2.00, SW4.00

      FOUNDATION Fieldbus, Ex. Hardware-versie 02.00. software versie 04.00.zz, FF, DevRev07. Stroomverbruik 15mA +/- 1 mA. Drukknop op elektronica. Gebruik: PMC71, PMP71/PMP75,PMD70/PMD75, FMD76/FMD77/FMD78,FMB70. Niet voor SIL.

    • Nr 30 Order code 71224775

      Electronics PA, HW02.00, SW4.01

      PROFIBUS PA, Ex. Hardware-versie 02.00. software versie 04.01.zz,PROFIBUS PA, Profile 3,02, DevRev03. Stroomverbruik 13mA +/- 1 mA. Drukknop op elektronica. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75,FMD76/FMD77/FMD78, FMB70. Niet voor de scheepvaart certificaat.

    • Nr 30 Order code 71224776

      Electronics PA, ext.p. b.,HW02.00,SW4.01

      PROFIBUS PA, Ex. Hardware-versie 02.00 software versie 04.01.zz, PROFIBUS PA, Profile 3,02, DevRev03. Stroomverbruik 13mA +/- 1 mA. Druk op de knop op de behuizing. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75,FMD76/FMD77/FMD78, FMB70.Niet voor de scheepvaart certificaat.

    • Nr 30 Order code 71263933

      Electronics HART Ex, v2.20

      4-20 mA. Softwareversie 02.20.zz, HART 7, DevRev22. Drukknop op elektronica. Gebruik: PMC71,PMP71/PMP75, PMD75,FMD77/FMD78,FMB70. Niet voor MID onderdelen certificaat (PMP71).

    • Nr 30 Order code 71263934

      Electronics HART Ex, ext. p. b., v2.20

      4-20 mA. softwareversie 02.20.zz, HART 7, DevRev22. Drukknop op de behuizing. Gebruik: PMC71, PMP71 / PMP75, PMD75, FMD77 / FMD78, FMB70. Niet voor mariene certificaat. Niet voor MID onderdelen certificaat (PMP71)

    • Nr 30 Order code 71386147

      Elektronics HART Ex, v2.30

      4-20 mA. Softwareversie 02.30.zz, HART 7, DevRev23. Drukknop op elektronica. Gebruik: FMB70,FMD77/FMD78,PMC71, PMD75, PMP71/PMP75. Niet voor MID-onderdelencertificaat (PMP71).

    • Nr 30 Order code 71386153

      Electronics HART Ex, ext. p. b., v2.30

      4-20 mA. Softwareversie 02.30.zz, HART 7, DevRev23. Drukknop op behuizing. Gebruik: FMB70, FMD77/FMD78,PMC71, PMD75,PMP71/PMP75. Niet voor MID-onderdelencertificaat (PMP71).

  • 31
    • Nr 31 Order code 52027785

      HistoROM / M-DAT, 16K

      Setup-/diagnostische software inbegrepen. Gebruik: FMB70, FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Nr 31 Order code 52027785

      HistoROM / M-DAT, 16K

      Setup-/diagnostische software inbegrepen. Gebruik: FMB70, FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

  • 35
    • Nr 35 Order code 52020434

      Terminal 3-pole, RFI, HART, TIIS

      RFI-filter. Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75, TIIS Ex ia.

    • Nr 35 Order code 52026605

      Terminal 2-pole, RFI, PA, TIIS

      RFI filter. PROFIBUS PA. Gebruik: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75. TIIS Ex ia, TIIS Ex d. PMC71, TIIS Ex ia.

    • Nr 35 Order code 52027691

      Terminal 2-pole, RFI, FF, Ex

      RFI-filter. FOUNDATION Fieldbus. Gebruik: FMB70, FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Nr 35 Order code 71028473

      Terminal 3p., RFI, HART, OVP, TIIS

      Overspanningsbeveiliging, RFI-filter. Gebruik: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Order code 71028475

      Uiteinde 2-polig, RFI, PA, OVP, Ex

      Overspanningsbeveiliging, RFI-filter. PROFIBUS PA. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB70.

    • Nr 35 Order code 71028476

      Terminal 2-pole, RFI, FF, OVP, Ex

      Overspanningsbeveiliging, RFI-filter. FOUNDATION Fieldbus. Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Nr 35 Order code 71121574

      Terminal 2-pole, RFI, PA, Ex

      RFI filter. PROFIBUS PA. Gebruik: FMB70, PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, Niet voor TIIS

    • Nr 35 Order code 71191892

      Terminal 3-pole,Li=0, RFI,HART,Ex ia/Exd

      RFI-filter. Gebruik: PMC71,PMP71/PMP75, PMD70/PMD75,FMD76/FMD77/FMD78, FMB70,FMD71/FMD72. Niet voor TIIS Ex ia, TIIS Ex d.

    • Nr 35 Order code 71191894

      Termin.3-p.,Li=0,RFI,HART,OVP,Ex ia/Exd

      Overspanningsbeveiliging, RFI-filter. Gebruik: PMC71/PMP71/PMP75, PMD70/PMD75,FMD76/FMD77/FMD78, FMB70,FMD71/FMD72. Niet voor TIIS Ex ia, TIIS Ex d.

  • 40
    • Nr 40 Order code 71002865

      Display module VU340, Cbar/Dbar/Dpilot S

      Digitaal display, 3 drukknoppen, Gebroken beugel. Talen DE/EN/FR/ES/IT/NL, Van software versie 02.00.zz; Gebruik: elektronica HART. Talen DE/EN/FR/ES/IT/NL/JA/ZH. Van software versie 02.01.zz; Elektronica HART. Talen DE/EN/FR/ES/IT/JA/ZH/RU, Van software versie 02.11.zz; Elektronica HART. Van software versie 04.00.zz; Elektronica PROFIBUS PA. Van software versie 03.00.zz; Electronics FOUNDATION Fieldbus, FMB70,FMD76/FMD77/FMD78,PMC71, PMD70/PMD75,PMP71/PMP72/PMP75. Van software versie 01.00.zz; Elektronica HART, FMD71/FMD72.

    • Order code 71043886

      Cable PE, L=2m/80inch, separate housing

      Aansluitkabel sensor>sep. housing. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB50/FMB51/FMB52/FMB70, PMC51/PMP51/PMP55.

    • Order code 71043888

      Cable PE, L=5m/200inch, separate housing

      Aansluitkabel kabel sensor>sep.behuizing Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB50/FMB51/FMB52/FMB70, PMC51/PMP51/PMP55.

    • Order code 71043889

      Cable PE, L=10m/400inch,separate housing

      Aansluitkabel sensor> sep. huisvesting. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB50/FMB51/FMB52/FMB70, PMC51/PMP51/PMP55.

    • Order code 71070738

      Cable FEP, L=5m/200inch,separate housing

      Aansluitkabel sensor> sep. huisvesting. Gebruik: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code 214880-0002

      Weld-in adapter UNI D65, 316L

      Flush mount process connection. Core hole: 65mm. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A compliant. Usage: FMB50, FMB70, FMD71/FMD78, FMI51/FMI52, FMP52, FTI51/FTI52, PMC51, PMP23, PMP55, PMP75.

    • Order code 52002041

      Inlasflens DRD-DN50-316L

      Front-inbouw van apparaten met DRD-flens. Materiaal: 316L. Afdichting: plat PTFE. FDA-compliant. Gebruik:FMB50,FMB70,FMD78, FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51, PMC71, PMP51/PMP55, PMP75.

    • Order code 52006262

      Weld-in adapter UNI D85, 316L

      Inbouw proces-verbinding. Core gat: 85mm. Materiaal: 316L. Seal: siliconen profiel pakking. Gebruik: FMI51/FMI52, FTI51/FTI52, FMP52,FMB70,FMB50, FMD78, FMD71, PMC51, PMP55, PMP75, PMP23.

    • Order code 52010173

      Weld-in adapter UNI D85, 316L, 3.1

      Inbouw proces-verbinding. Core gat: 85mm. Materiaal: 316L. Inspectie cert. EN10204-3.1 materiaal. Seal: siliconen profiel pakking. FDA, EHEDG, 3-A compliant. Gebruik: FMI51/FMI52, FTI51/FTI52, FMP52,FMB50,FMB70,FMD71,FMD78,PMC51, PMP23,PMP55,PMP75.

    • Order code 52010174

      Weld-in adapter UNI D65, 316L, 3.1

      Inbouw proces-verbinding. Core gat: 65mm. Materiaal: 316L. Inspectie cert. EN10204-3.1 materiaal. Seal: siliconen profiel pakking. FDA, EHEDG, 3-A compliant. Gebruik: FMI51/FMI52, FTI51/FTI52, FMP52, FMB70, FMB50, FMD71, FMD78, PMC51, PMP23, PMP55, PMP75.

    • Order code 52011899

      Weld-in adapter DRD DN50, 316L, 3.1

      Inbouw proces aansluiting van apparaten met DRD flens. Materiaal: 316L. Inspectie cert. EN10204-3.1 materiaal. Seal: PTFE plat. FDA compliant. Gebruik: FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51,PMP51,PMP55,PMC71,PMP75,FMB50, FMB70,FMD78.

    • Order code 52024469

      Laspuntstuk G1-1/2, 316L

      Laspuntstuk G1-1/2 Materiaal: 316L Correcte installatie alleen met dummy. Gebruik:PMC71,PMP71,PMP75,FMB50/FMB51/ FMB52,FMB70,PMC51,PMP51/PMP55.

    • Order code 52024470

      Weld-in adapter G1-1/2, 316L, 3.1

      Montageproces aansluiting G1-1 / 2. Materiaal: 316L. Inspectie cert. NL 10.204-3,1 materiaal. Gebruik: PMC71, PMP71, PMP75, FMB50/51/52, FMB70, PMC51, PMP51, PMP55.

    • Order code 916743-0000

      Weld-in adapter DRD DN50, 304

      Flush mount process connection. Material: 304. Seal: PTFE flat. FDA compliant. Usage: Flush mount FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51, PMP51, PMP55, PMC71, PMP75, FMB50, FMB70, FMD78.

  • 50
    • Order code 52024228

      Vlakke afdichting 50x65x1 PTFE,FDA ,5st.

      Monteer de inlasadapter DRD-DN50. Inbouw FTL50H/FTL51H, PMC51, drukapparaat.

  • 57
    • Nr 57 Order code 52023572

      Siliconen profielafdichting (5 stuks)

      Procespakking universele procesaanpassing. FDA vermeld. Gebruik: FMB50, FMB70, FMI51/FMI52, FTI51/FTI52/FTI55, PMC51.

    • Nr 57 Order code 71100719

      Profieldichting EPDM, 5 stuks

      Process gasket universal adapter. Usage: FMB50, FMB70, PMC51.

    • Nr 57 Order code 71431380

      Profielafdichting EPDM/SST, EHEDG,1 stuk

      Procesafdichting universele adapter. Pakking met metalen ring. EHEDG-goedkeuring. Gebruik: FMB50, FMB70, FMD71/FMD78, PMC51, PMP23.

    • Order code 71114172

      Adapter Uni, DIN11851 DN40, 316L

      Sleuven-nut, proces-verbinding. Materiaal: 316L. Seal: siliconen profiel pakking. FDA, EHEDG, 3A voldoen. Gebruik: PMC51,FMB50.

    • Order code 71114173

      Adapter Uni, DIN11851 DN50, 316L

      Slotted-nut, proces-verbinding. Materiaal: 316L. Seal: siliconen profiel pakking. FDA, EHEDG, 3A voldoen. Gebruik: PMC51, FMB50 ..

    • Order code 71114174

      Adapter Uni, DRD DN50, 65mm, 316L

      Slotted-nut, proces-verbinding. Materiaal: 316L. Seal: siliconen profiel pakking. FDA, EHEDG, 3A voldoen. Gebruik: PMC51, FMB50.

    • Order code 71114177

      Adapter Univ-/Variv N DN40-162 316L

      Universele adapter, Varivent procesaansluiting. Materiaal: 316L. Gebruik: PMC51, FMB50.

    • Order code 71114178

      Adapter UNI, DIN11851 DN40, 316L, 3.1

      Universele adapter, DIN11851 DN40, wartelmoer, procesaansluiting. Materiaal: 316L. Materiaal cert. EN10204-3.1. Gebruik: PMC51, FMB50.

    • Order code 71114205

      Adapter Uni, DIN11851 DN50, 316L 3.1

      Slotted-nut, proces-verbinding. Materiaal: 316L. Inspectie cert. NL 10.204-3,1 materiaal. Seal: siliconen profiel pakking. FDA, EHEDG, 3-A te voldoen. Gebruik: PMC51, FMB50.

    • Order code 71114206

      Adapter Uni, DRD DN50, 65mm, 316L 3.1

      Slotted-nut, proces-verbinding. Materiaal: 316L. Inspectie cert. NL 10.204-3,1 materiaal. Seal: siliconen profiel pakking. FDA, EHEDG, 3-A te voldoen. Gebruik: PMC51, FMB50.B50.

    • Order code 71114208

      Adapter Univ-/Variv N DN40 316L 3.1

      Slotted-nut, proces-verbinding. Materiaal: 316L. Inspectie cert. EN10204-3.1 materiaal. Seal: siliconen profiel pakking. FDA, EHEDG, 3A voldoen. Gebruik: PMC51_110_UNJ/UPJ, FMB50_110 UNJ/UPJ.

    • Order code 52024471

      Weld-in dummy, adapter G1-1/2

      Ter voorkoming van vervorming tijdens het lassen van laspuntstuk 52024469 / 52024470.

    • Order code 71114176

      Adapter UNI, Clamp 2", 316L

      Universele adapter, Triclamp 2" procesaansluiting. Materiaal: 316L. Gebruik: FMB50, FMB70, PMC51.

    • Order code 71114178

      Adapter UNI, DIN11851 DN40, 316L, 3.1

      Universele adapter, DIN11851 DN40, wartelmoer, procesaansluiting. Materiaal: 316L. Materiaal cert. EN10204-3.1. Gebruik: PMC51, FMB50.

    • Order code 71114207

      Adapter UNI, Clamp 2", 316L, 3.1

      Slotted-nut, proces-verbinding. Materiaal: 316L. Inspectie cert. NL 10.204-3,1 materiaal. Seal: siliconen profiel pakking. FDA, EHEDG, 3-A te voldoen. Gebruik: PMC51, FMB50.

    • Order code 71350315

      Adapter Uni, Clamp 3", 316L

      Procesaansluiting. Materiaal: 316L. FDA, 3-A voldoen. Gebruik: FMB50, FMB70, FMD71, FMD78, PMC51, PMP23, PMP55.

    • Order code 71114160

      Ìnlas adapter Uni 6" D85, 316L

      Inbouw proces-verbinding. Core gat: 85mm. Materiaal: 316L. Seal: siliconen profiel pakking FDA voldoen. Gebruik: FMB50, FMB70.

    • Order code 71114171

      Inlas adapter Uni 6" D85, 316L, 3.1

      Inbouw proces-verbinding. Kern gat: 85mm. Materiaal: 316L. Inspectie cert. EN10204-3.1 materiaal. Afdichting: siliconen profiel pakking FDA voldoen. Gebruik: FMB50, FMB70.

    • Order code 71304770

      Mountingset, housing T14, special

      Materiaal: 316L. Gebruik: montagekit aan de eigen montagebeugel te hechten/bescherming tegen weersinvloeden. dekking, PMC71, PMP71 / PMP75, FMB70.

    • Order code 71377369

      Flushing ring NPS 1" Cl. 150-2500, 316L

      Bestaat uit: 2x spoelringaansluiting. ASME FNPT 1/2 draad. Gebruik: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.

    • Order code 71377370

      Flushing ring NPS 2" Cl. 150-2500, 316L

      Bestaat uit: 2x spoelringaansluiting. ASME FNPT 1/2 draad Gebruik: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.

    • Order code 71377371

      Flushing ring NPS 3" Cl. 150-2500, 316L

      Bestaat uit: 2x spoelringaansluiting. ASME FNPT 1/2 draad. Gebruik: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.

    • Order code 71377380

      Flushing ring DN50, PN16-400, 316L

      Bestaat uit: 2x spoelringaansluiting. ASME FNPT 1/2 draad Gebruik: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.

    • Order code 71377383

      Flushing ring DN80, PN16-400, 316L

      Bestaat uit: 2x spoelringaansluiting. ASME FNPT 1/2 draad Gebruik: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.

    • Order code 71102216

      Montageset Cerabar,Deltapilot,Levelflex

      Materiaal: RVS 304. Geschikt voor: wand/pijp montage (2"), PMC71, PMP71/75, FMB70, PMC51, PMP51/55, FMB50/51/52/53. FMP50/51/52/53/54/55/56/57.

    • Order code XPRFID-

      Spare RFID TAG

      Consists of: RFID TAG, fixing wire, crimp sleeve.