Overzicht specificaties
-
Accuracy
0,1%
"PLATINUM" 0,075% -
Max. meetfout
0,1%
"PLATINUM" 0,075% -
Process temperature
-40 °C...85 °C
(-40 °F...185 °F) -
Medium temperature range
Temperature gradient from pressure piping
-
Pressure measuring range
10mbar...40bar
(0.15...580psi) -
Process pressure absolute / max. overpressure limit
160 bar
-
Main wetted parts
316L
-
Max. process pressure
10 mbar...40 bar
(0.15...580 psi) -
Material process membrane
316L, AlloyC,
-
Measuring cell
10 mbar...40 bar
(0.15...580 psi)
Toepassingsgebied
De Deltabar PMD55-drukverschiltransmitter met piëzoresistieve sensor en gelast metalen membraan wordt veel gebruikt in proces- en milieutoepassingen voor continue drukverschilmetingen in vloeistoffen, dampen en gassen. Quick Setup met instelbaar meetbereik maakt een eenvoudige inbedrijfstelling mogelijk, verlaagt de kosten en bespaart tijd. SIL2 volgens IEC 61508 / IEC 61511.
Voor niveau-, volume- of massameting in vloeistoffen, voor drukverschilbewaking, bijv. van filters en pompen, en voor flowmeting (volume- of massastroom) in combinatie met primaire elementen in gassen, dampen en vloeistoffen.
Procesaansluitingen: schroefdraad
Procestemperatuur: -40 tot 85 °C (-40 tot 185 °F)
Meetbereik: 0,5 mbar tot 40 bar (0,0072 tot 600 psi)
Nauwkeurigheid: ± 0,1%, "Platina" ± 0,075% (optioneel)
Internationale certificaten voor explosieveiligheid, SIL
Voordelen
Eenvoudige menugestuurde inbedrijfstelling via lokaal display, 4-20 mA met HART, PROFIBUS PA, FOUNDATION Fieldbus
Eenvoudige aanpassing aan impulsleidingen - mogelijkheid om de leidingen met hoge en met lage druk te wisselen via elektrische schakelaar op de hoofdelektronica
Compact ontwerp en modulair concept voor eenvoudige vervanging van het display of de elektronica
Procesdruk tot SIL2, gecertificeerd volgens IEC 61508 en IEC 61511
Internationaal inzetbaar dankzij een breed scala aan goedkeuringen
Video's
-
Drukmeetprincipe
Lean selectie
-
Standaardproducten
- Betrouwbaar, robuust en onderhoudsarm
Technische topkwaliteit
Eenvoud

-
Eenvoudige producten
- Gemakkelijk te selecteren, installeren en gebruiken
Technische topkwaliteit
Eenvoud
-
Standaardproducten
- Betrouwbaar, robuust en onderhoudsarm
Technische topkwaliteit
Eenvoud
-
Gespecialiseerde producten
- Ontworpen voor veeleisende applicaties
Technische topkwaliteit
Eenvoud
Variabel
FLEX selectie | Technische topkwaliteit | Eenvoud |
---|---|---|
Fundamental selectie Voldoe aan uw basismeetvoorwaarden |
Technische topkwaliteit
|
Eenvoud
|
Lean selectie Beheers eenvoudig uw belangrijkste processen |
Technische topkwaliteit
|
Eenvoud
|
Extended selectie Optimaliseer uw processen met innovatieve technologieën |
Technische topkwaliteit
|
Eenvoud
|
Xpert selectie Beheers uw meest uitdagende applicaties |
Technische topkwaliteit
|
Eenvoud
Variabel |
-
Meetprincipe
Differential pressure
-
Product headline
Digital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability -
Max. meetfout
0,1%
"PLATINUM" 0,075% -
Max. process pressure
10 mbar...40 bar
(0.15...580 psi) -
Medium temperature range
Temperature gradient from pressure piping
-
Display/Operation
Option
-
Outputs
4...20mA HART
-
Digital communication
HART
-
Hazardous area approvals
ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS
-
Functional safety
SIL
-
Material certificates
NACE MR0103
NACE MR0175
EN10204-3.1
-
Meetprincipe
Differential pressure
-
Product headline
Digital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability -
Max. meetfout
0,1%
"PLATINUM" 0,075% -
Max. process pressure
10mbar...40bar
(0.15...580psi) -
Medium temperature range
Temperature gradient from pressure piping
-
Display/Operation
Option
-
Outputs
4...20mA HART
-
Digital communication
HART
-
Hazardous area approvals
ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS
-
Functional safety
SIL
-
Material certificates
NACE MR0103
NACE MR0175
EN10204-3.1
-
Meetprincipe
Differential pressure
-
Characteristic
Digital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability -
Supply voltage
4...20 mA HART
11,5...45V DC (Non Ex):
Ex ia: 11,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex) -
Reference Accuracy
Standard 0.1%
Platinum 0.075% -
Long term stability
0.05% of URL/ year
0.13% of URL/ 5 years
0.23% of URL/ 10 years -
Process temperature
-40°C...+85°C
(-40°F...+185°F) -
Ambient temperature
-40°C...+85°C
(-40°F...+185°F) -
Measuring cell
10 mbar...40 bar
(0.15...580 psi) -
Smallest calibratable span
10 mbar (0.15 psi)
-
Max. Turn down
20:1
-
Max. overpressure limit
on one side:
160 bar
(2300 psi) -
Process connection
1/4-18 NPT
-
Material process membrane
316L, AlloyC,
-
Material gasket
Viton, PTFE, EPDM, NBR
-
Fill fluid
Silicone oil
Inert oil -
Material housing
Die-cast aluminum
-
Communication
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus -
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
-
Safety approvals
SIL
-
Design approvals
NACE MR0175
EN10204-3.1 -
Successor
PMD55B
-
Meetprincipe
Differential pressure
-
Product headline
Digital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability -
Max. meetfout
0,1%
"PLATINUM" 0,075% -
Max. process pressure
10mbar...40bar
(0.15...580psi) -
Medium temperature range
Temperature gradient from pressure piping
-
Display/Operation
Option
-
Outputs
4...20mA HART
-
Digital communication
HART
-
Hazardous area approvals
ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS
-
Functional safety
SIL
-
Material certificates
NACE MR0103
NACE MR0175
EN10204-3.1
-
Meetprincipe
Differential pressure
-
Characteristic / Application
Digital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability -
Supply / Communication
4...20mA HART:
11,5...45V DC
Ex ia: 11,5...30V DC -
Accuracy
0,1%
"PLATINUM" 0,075% -
Long term stability
0,05% of URL/year
0,125% of URL/5 years -
Ambient temperature
-40°C...85°C
(-40°F...185°F) -
Process temperature
-40 °C...85 °C
(-40 °F...185 °F) -
Process pressure absolute / max. overpressure limit
160 bar
-
Pressure measuring range
10mbar...40bar
(0.15...580psi) -
Main wetted parts
316L
-
Process connection
1/4-18 NPT
-
Communication
4...20mA HART
PROFIBUS PA
FOUNDATION Fieldbus -
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
-
Safety approvals
SIL
-
Design approvals
EN 10204-3.1
NACE MR0175, MR0103
AD2000 -
Options
4-line digital display
Aluminium housing -
Successor
PMD55B
-
Application limits
Measuring cell:
Metal welded
Configureer om de CAD-tekeningen van dit product te downloaden
Kies uit één van de voorgestelde opties
-
-- selected coding-- selected label99.999,00<%label%>
-
Zoekt u meer opties? Gebruik dan de individuele configurator om verder te gaan.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Zoekt u meer opties? Gebruik dan de individuele configurator om verder te gaan.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
-
Prijzen per stuk
-
<%range%><%price%>
-
- Optionele extra's
Individuele configuratie
Vaak samen aangeschaft
Accessoires
Gerelateerde producten