Specs at a glance
-
Accuracy
Standard 0.1%
Platinum 0.075% -
Process temperature
-40°C...130°C
(-40°F...266°F) -
Pressure measuring range
1 bar...400 bar
(15 psi...6000 psi) -
Process pressure / max. overpressure limit
600 bar (9000 psi)
-
Main wetted parts
316L
-
Max. measurement distance
4000 m (13.123 ft) H2O
-
Material process membrane
316L, AlloyC,
Rhodium>Gold -
Measuring cell
400mbar...400bar
(5.8 psi...6000psi)
relative/ absolute
Field of application
The Cerabar PMP51 digital pressure transmitter with metal membrane is typically used in process and hygiene applications for pressure, level, volume or mass measurement in liquids or gases. PMP51 is designed for high pressure applications up to 400bar. Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. SIL2 according to IEC 61508 and IEC 61511.
Single chamber aluminum or stainless steel (316L) housing.
Process connections: Threads, flanges or hygienic connections
Process temperature: -40 to +130°C (-40 to +266°F), 150°C (302°F) for 1h
Measuring range: -1/0 up to +400bar (-15/0 up to +6,000psi)
Accuracy: ±0.1%, "Platinum" ±0.075%
International explosion protection certificates, SIL, hygienic approvals, marine approvals
Benefits
Accurate measurement of the process value even in the case of changing process temperature
Process safety assured with small flush mounted process connections in hygienic applications
For process pressure monitoring up to SIL2, certified to IEC 61508 and IEC 61511
Modular concept for easy replacement of display or electronics
Easy menu-guided commissioning via on-site display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
Seamless and independent system integration (HART/PA/FF)
-
Available with mounted manifolds: always fit, always tested for leaks
Videos
Lean selection
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Technical Information (TI)
TI Cerabar M PMC51, PMP51 , PMP55
English version - 04/2024
Process pressure measurement 4 to 20 mA, HART, IO-Link, PA, FF
EN 01/04/202422/08/202206/09/202101/04/202016/04/2019Language:
English
Version:
01/04/2024
File size:
3.8 MB
File name:
TI00436PEN_3224-00.pdf
-
-
-
Operating Instruction (BA)
Cerabar M /Deltabar M /Deltapilot M Operating Instructions PROFIBUS PA
English version - 07/2016
Cerabar M PMC51, PMP51, PMP55, Pressure transmitter Deltabar M PMD55 Differential pressure transmitter Deltapilot M FM
EN 13/07/201610/12/201411/06/201417/08/201225/01/2012Language:
English
Version:
13/07/2016
File size:
7.8 MB
File name:
BA00383PEN_0816.pdf
-
-
-
Technical Information (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN 25/03/202415/09/202328/10/202130/07/202119/06/2020Language:
English
Version:
25/03/2024
File size:
1.1 MB
File name:
TI00426FEN_2524.pdf
-
-
-
Technical Information (TI)
TI Cerabar M PMC51, PMP51 , PMP55
Process pressure measurement
4 to 20 mA, HART, IO-Link, PA, FFEN 01/04/202422/08/202206/09/202101/04/202016/04/2019Language:
English
Version:
01/04/2024
File size:
3.8 MB
File name:
TI00436PEN_3224-00.pdf
-
-
-
Operating Instruction (BA)
Cerabar M PMC51, PMP51/55 Analog
With ceramic and silicon sensors
modular design and easy
operationEN 13/07/201610/12/201411/06/201417/08/201225/01/2012Language:
English
Version:
13/07/2016
File size:
1.1 MB
File name:
BA00385PEN_2016.pdf
-
-
-
Operating Instruction (BA)
Cerabar M /Deltabar M /Deltapilot M Operating Instructions PROFIBUS PA
Cerabar M PMC51, PMP51, PMP55, Pressure transmitter
Deltabar M
PMD55 Differential pressure transmitter Deltapilot M FMEN 13/07/201610/12/201411/06/201417/08/201225/01/2012Language:
English
Version:
13/07/2016
File size:
7.8 MB
File name:
BA00383PEN_0816.pdf
-
-
-
Operating Instruction (BA)
Cerabar M, Deltapilot M
Pressure / hydrostatics
IO-LinkEN 22/08/202231/07/2021Language:
English
Version:
22/08/2022
File size:
1.7 MB
File name:
BA02136PEN_0222-00.pdf
-
-
-
Operating Instruction (BA)
Cerabar M / Deltabar M / Deltapilot M, Operating Instructions FOUNDATION Fieldbus
Cerabar M PMC51, PMP51, PMP55 Pressure transmitter
Deltabar M PMD55 Differential pressure transmitter
Deltapilot M FMB50 Hydrostatic pressure transmitterEN 13/07/201610/12/201411/06/201417/08/201225/01/2012Language:
English
Version:
13/07/2016
File size:
7.8 MB
File name:
BA00384PEN_0816.pdf
-
-
-
Operating Instruction (BA)
Cerabar M, Deltabar M, Deltapilot M HART (V 01.00.zz)
Cerabar M PMC51, PMP51/55 Pressure transmitter
Deltabar M
PMD55
Differential pressure transmitter
Deltapilot M FMB50/5EN 13/07/201610/12/201411/06/201417/08/201225/01/2012Language:
English
Version:
13/07/2016
File size:
4.8 MB
File name:
BA00382PEN_2016.pdf
-
-
-
Short Instruction (KA)
Cerabar M PMC51, PMP51, PMP55
Process pressure measurement
FOUNDATION FieldbusEN 30/09/202113/07/201610/12/201411/06/201425/01/2012Language:
English
Version:
30/09/2021
File size:
914.7 KB
File name:
KA01032PEN_0621-00.pdf
-
-
-
Short Instruction (KA)
Cerabar M PMC51, PMP51, PMP55
Process pressure measurement
PROFIBUS PAEN 30/09/202113/07/201610/12/201411/06/201425/01/2012Language:
English
Version:
30/09/2021
File size:
943.6 KB
File name:
KA01031PEN_0621-00.pdf
-
-
-
Short Instruction (KA)
Cerabar M PMC51, PMP51, PMP55
Process pressure measurement
AnalogEN 15/12/202113/07/201610/12/201411/06/201425/01/2012Language:
English
Version:
15/12/2021
File size:
830.8 KB
File name:
KA01036PEN_1821-00.pdf
-
-
-
Short Instruction (KA)
Cerabar M PMC51, PMP51, PMP55
Process pressure measurement
HARTEN 15/12/202110/12/201411/06/201425/01/201230/11/2010Language:
English
Version:
15/12/2021
File size:
858 KB
File name:
KA01030PEN_1821-00.pdf
-
-
-
Short Instruction (KA)
Cerabar M PMC51, PMP51, PMP55
Process pressure measurement
IO-LinkEN 22/08/202209/09/2021Language:
English
Version:
22/08/2022
File size:
997.3 KB
File name:
KA01522PEN_0222-00.pdf
-
-
-
Installation Instructions (EA)
Electronics for Cerabar M, Deltapilot M Installation Instruction
CerabarM PMC51, PMP51, PMP55,
Deltapilot M FMB5xEN 30/09/201312/04/2012Language:
English
Version:
30/09/2013
File size:
556.1 KB
File name:
EA00016PA2_1313.pdf
-
-
-
Installation Instructions (EA)
M12 plug, IO-Link
Deltapilot M FMB50
Cerabar M PMC51, PMP51, PMP55EN 23/11/2022Language:
English
Version:
23/11/2022
File size:
730.3 KB
File name:
EA01457PEN_0122-00.pdf
-
-
-
Installation Instructions (EA)
Cable separate version Installation Instructions
Cerabar M, Cerabar S, Deltabar S, Deltapilot M, Deltapilot S
EN 31/01/2017Language:
English
Version:
31/01/2017
File size:
324.7 KB
File name:
EA01192PA2_0117.pdf
-
-
-
Installation Instructions (EA)
Installation instruction - Ground terminal T14/T15/T17, F30/F31
Cerabar S, Deltabar S, Deltabar, Cerabar M, Deltabar M, Deltapilot M
EN 22/06/2015Language:
English
Version:
22/06/2015
File size:
282.8 KB
File name:
EA01131PA2_0115.pdf
-
-
-
Installation Instructions (EA)
Harting plug HAN7D Installation instruction
Cerabar M/S, Deltabar M/S, Deltapilot M/S
EN 11/04/2012Language:
English
Version:
11/04/2012
File size:
292.8 KB
File name:
EA0006PA2_0810.pdf
-
-
-
Installation Instructions (EA)
Display module VU340 Installation instruction
Cerabar M, Deltabar M, Deltapilot M
EN 12/04/2012Language:
English
Version:
12/04/2012
File size:
233.2 KB
File name:
EA0015P-a2_0909.pdf
-
-
-
Installation Instructions (EA)
Sealing kit Installation Instruction
Cerabar
EN 08/08/201623/07/201507/04/2015Language:
English
Version:
08/08/2016
File size:
205.3 KB
File name:
EA01128PA2_0316.pdf
-
-
-
Installation Instructions (EA)
Plug 3-pole, M12/M20 Installation instruction
Cerabar S, Deltabar S, Deltapilot S
EN 25/04/2012Language:
English
Version:
25/04/2012
File size:
596.1 KB
File name:
EA00060PA2_0112.pdf
-
-
-
Ex Safety Instruction (XA)
Cerabar M PMC51, PMP51, PMP55
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex ta IIIC T75°C Da
Ex tb IIIC T75°C DbEN 24/02/2020Language:
English
Version:
24/02/2020
File size:
122.1 KB
File name:
XA01953PEN_0119.pdf
-
-
-
Ex Safety Instruction (XA)
Cerabar M PMP51, PMP55
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
1Ex d IIC T6/T4 GbEN 24/02/202031/03/201808/02/2017Language:
English
Version:
24/02/2020
File size:
123.3 KB
File name:
XA01401PEN_0320.pdf
-
-
-
Ex Safety Instruction (XA)
XA Cerabar M PMC51, PMP51, PMP55
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex ia IIC T6...T4 Ga/Gb
Ex ia IIC T6...T4 GbEN 10/01/202302/06/2014Language:
English
Version:
10/01/2023
File size:
404.1 KB
File name:
XA01302PEN_0223-00.pdf
-
-
-
Ex Safety Instruction (XA)
Safety Instructions Cerabar M PMC51, PMP51, PMP55
Ex ic IIC T6...T4 Gc
Ex ic IIC T6...T3 Gc
IECEx KEM 09.0016EN 18/07/201331/12/201001/05/2009Language:
English
Version:
18/07/2013
File size:
105.8 KB
File name:
XA00488PEN_1413.pdf
-
-
-
Ex Safety Instruction (XA)
Cerabar M PMP51, PMP55
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
II1/2 G Ex ia IIC Ga/Gb
II 2 G Ex db IIC GbEN 04/04/202211/08/201414/11/201201/03/2010Language:
English
Version:
04/04/2022
File size:
413.9 KB
File name:
XA00504PEN_1622-00.pdf
-
-
-
Ex Safety Instruction (XA)
Safety Instructions Cerabar M PMC51, PMP51, PMP55
Intrinsically safe
Class I, Div. 1, Groups A, B, C, D, Class II, Div. 1, Groups E, F, G,
Class III; Ex ia IIC T6
Suitable for Class I, Div. 2, Groups A, B, C, D, Class II, Div. 1,
Groups E, F, G;
Hazardous location installationEN 10/04/201709/07/201431/03/2011Language:
English
Version:
10/04/2017
File size:
464.9 KB
File name:
XA00558PEN_0317.pdf
-
-
-
Ex Safety Instruction (XA)
Safety Instructions Cerabar M PMP51, PMP55
Intrinsically safe
Class I, Div. 1, Groups A, B, C, D, Class II, Div. 1, Groups E, F, G,
Class III;
Ex ia IIC T6
Explosionprooffor Class I, Div. 1, Groups B, C, D
IS / XPEN 10/04/201709/07/201431/03/2011Language:
English
Version:
10/04/2017
File size:
462.4 KB
File name:
XA00561PEN_0317.pdf
-
-
-
Ex Safety Instruction (XA)
XA Cerabar M PMP51, PMP55
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex db IIC T6/T4 GbEN 13/03/202409/12/201905/03/201521/02/201201/04/2010Language:
English
Version:
13/03/2024
File size:
492.2 KB
File name:
XA00515PEN_1624-00.pdf
-
-
-
Ex Safety Instruction (XA)
Cerabar M PMC51, PMP51, PMP55
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
ATEX, IECEx:
Ex ic IIC GcEN 19/08/202124/04/201705/04/201618/07/201301/05/2011Language:
English
Version:
19/08/2021
File size:
404.3 KB
File name:
XA00489PEN_1721.pdf
-
-
-
Ex Safety Instruction (XA)
Safety Instructions Cerabar M PMC51, PMP51, PMP55
FM
IS
Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G;
Division 2 and Zone 2 installation
Nonincendive, Class I, Div. 2, Groups A, B, C, D;
Class II, III installation
DIP for Class II, III, Div. 1, Groups E, F, GEN 27/03/201724/06/201421/03/2011Language: