Overzicht specificaties
-
Max. meetfout
Volume flow:
- ± 0.5 % o.r. ± 0.02% o.f.s. for 0.5 to 10 m/s (1.6 to 33 ft/s)
- ± 0.07 % o.f.s. for flow velocities < 0.5 m/s (1.64 ft/s) -
Measuring range
0.025 to 5 m/s (0.02 to 16.4 ft/s)
0 to 6360 dm3/min (0 to 1680 gal/min) -
Medium temperature range
0 to 150° (17.8 to 302 °F)
-
Max. process pressure
PN 25 / ASME Cl. 150
-
Wetted materials
Measuring tube: 1.4301 (F304)
Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105
Toepassingsgebied
Measuring of demineralized water in utilities, for example in boiler condensate return lines, requires reliable devices. Prosonic Flow E 100 provides economical and accurate bidirectional flow measurement across all industries. With its integrated temperature measurement, Prosonic Flow E 100 proves to be a multivariable flowmeter for considerable additional value in your plant. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.
The measuring principle is independent of pressure, density, temperature and conductivity
Bidirectional measuring of demineralized water applications for utilities, e.g. boiler condensate return lines
Device properties:
Accuracy up to ±0.5 % (flow) or acc. to EN 1434 Cl. 2, ±2.0 °C (± 3.6 °F) (temp.)
Process temperatures up to 150 °C (302 °F)
Entire meter housing made of stainless steel
4-20 mA HART, pulse/frequency output
Local display for reading and monitoring available
Robust transmitter housing
Voordelen
Long-term stability – reliable, robust sensor
Reducing further measuring point – multivariable device
Dependable flow measurement – high turndown (200:1)
Time-saving local operation without additional software and hardware – integrated web server
Extended calibration intervals – integrated device verification due to Heartbeat Technology
Easy commissioning – brief parameter explanations
Video's
Extended selectie
-
High-end producten
- Functioneel en uiterst doelmatig
Technische topkwaliteit
Eenvoud
-
Eenvoudige producten
- Gemakkelijk te selecteren, installeren en gebruiken
Technische topkwaliteit
Eenvoud
-
Standaardproducten
- Betrouwbaar, robuust en onderhoudsarm
Technische topkwaliteit
Eenvoud
-
Gespecialiseerde producten
- Ontworpen voor veeleisende applicaties
Technische topkwaliteit
Eenvoud
Variabel
FLEX selectie | Technische topkwaliteit | Eenvoud |
---|---|---|
Fundamental selectie Voldoe aan uw basismeetvoorwaarden |
Technische topkwaliteit
|
Eenvoud
|
Lean selectie Beheers eenvoudig uw belangrijkste processen |
Technische topkwaliteit
|
Eenvoud
|
Extended selectie Optimaliseer uw processen met innovatieve technologieën |
Technische topkwaliteit
|
Eenvoud
|
Xpert selectie Beheers uw meest uitdagende applicaties |
Technische topkwaliteit
|
Eenvoud
Variabel |
-
-
Technische informatie (TI)
Proline Prosonic Flow E 100
Engelse versie - 06/2020
Ultrasonic time-of-flight flowmeter
EN NL 18/06/202001/11/201902/07/201801/12/2017Taal:
Engels
Versie:
18/06/2020
Bestandsgrootte:
2.5 MB
Bestandsnaam:
TI01345DEN_0420.pdf
-
-
-
Technische informatie (TI)
Proline Prosonic Flow E 100
Ultrasonic time-of-flight flowmeter
EN NL 18/06/202001/11/201902/07/201801/12/2017Taal:
Engels
Versie:
18/06/2020
Bestandsgrootte:
2.5 MB
Bestandsnaam:
TI01345DEN_0420.pdf
-
-
-
Bedieningshandleiding (BA)
Proline Prosonic Flow E 100 HART
Ultrasonic time-of-flight flowmeter
EN NL 18/06/202001/11/201901/12/2017Taal:
Engels
Versie:
18/06/2020
Bestandsgrootte:
5 MB
Bestandsnaam:
BA01769DEN_0320.pdf
-
-
-
Instrumentparameters (GP)
Proline Prosonic Flow 100 HART Description of Device Parameters
Ultrasonic time-of-flight flowmeter
EN NL 01/12/2017Taal:
Engels
Versie:
01/12/2017
Bestandsgrootte:
1.6 MB
Bestandsnaam:
GP01124DEN_0117.pdf
-
-
-
Beknopte instructie (KA)
Proline 100 HART
Transmitter with ultrasonic time-of-flight sensor
EN NL 18/06/202001/12/2017Taal:
Engels
Versie:
18/06/2020
Bestandsgrootte:
2.5 MB
Bestandsnaam:
KA01330DEN_0220.pdf
-
-
-
Beknopte instructie (KA)
Proline Prosonic Flow E Brief Operating Instructions
Proline Prosonic Flow E
Ultrasonic time-of-flight sensorEN NL 01/12/2017Taal:
Engels
Versie:
01/12/2017
Bestandsgrootte:
580.1 KB
Bestandsnaam:
KA01329DEN_0117.pdf
-
-
-
Montage-instructies (EA)
EA Replacing Small parts
Proline 10, 100, 400, 800 Index C, 500, 500-digital, CNG-, LNG-, LPGmass
EN NL 01/01/202401/05/202101/04/202131/07/202002/08/2019Taal:
Engels
Versie:
01/01/2024
Bestandsgrootte:
518.1 KB
Bestandsnaam:
EA01119DA2_0923-00.pdf
-
-
-
Montage-instructies (EA)
Replacing Display module, non Ex, Zone 2, Class 1 Div. 2 Installation Instructions
Promass 100, Promag 100, Prosonic Flow E 100
EN NL 01/12/201708/10/2014Taal:
Engels
Versie:
01/12/2017
Bestandsgrootte:
340.9 KB
Bestandsnaam:
EA01109DA2_0217.pdf
-
-
-
Montage-instructies (EA)
EA Replacing Spare Parts
CNG-, LNG-, LPGmass, Proline 100, 300, 400 Index C, 500, 500-digital
EN NL 01/01/202415/12/202101/06/202101/06/202002/08/2019Taal:
Engels
Versie:
01/01/2024
Bestandsgrootte:
1.9 MB
Bestandsnaam:
EA01018DA2_1523-00.pdf
-
-
-
Montage-instructies (EA)
Replacing the Electronics Module
Prosonic Flow E 100, Prosonic Flow E Heat
EN NL 01/07/202004/06/201801/12/2017Taal:
Engels
Versie:
01/07/2020
Bestandsgrootte:
604.1 KB
Bestandsnaam:
EA01219DA2_0320.pdf
-
-
-
Montage-instructies (EA)
Activating application packages
Promag 100, 200, 400, Promass 100, 200, Prosonic Flow 100, 200, Prowirl
200, t-mass 150EN NL 03/03/202015/02/2019Taal:
Engels
Versie:
03/03/2020
Bestandsgrootte:
406.9 KB
Bestandsnaam:
EA01249DA2_0220.pdf
-