Proline Promag W 400
Electromagnetic flowmeter

Picture of Electromagnetic flowmeter Proline Promag W 400 / 5W4C for the water & wastewater industry ©Endress+Hauser

Proline Promag W 400 for the water and wastewater industry

The Electromagnetic Flow Measuring Principle

Introduction of Proline Web server

Versatile standard flowmeter for the water and wastewater industry

With its international approvals for custody transfer as well as drinking water, Promag W serves the broadest variety of applications. It is available as both compact or remote version. Promag W 400 saves time and costs thanks to the broad functionality of its transmitter optimized for Water & Wastewater. In addition, Heartbeat Technology ensures compliance and process safety at all times.

  • Voordelen

    • With EN ISO 12944 corrosion protection for underground installation or permanent underwater use

    • Flexible engineering – sensor with welded or lap-joint process connections

    • Reliable measurement – accurate measured values even with 0 DN inlet run

    • Improved...

  • Toepassingsgebied

    • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity

    • Ideal for water measurement , e.g. drinking water, utility water and industrial/municipal wastewater

    Device properties

    • International drinking...

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Electromagnetic

  • Product headline

    Sensor with certified corrosion protection (EN ISO 12944) and a state‐of‐the‐art transmitter for Water & Wastewater. For direct underground installation or permanent underwater use. The specialist in the water and wastewater industry for the most demanding applications.

  • Sensor features

    Secure, reliable long‐term operation – robust and completely welded sensor. Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance‐free – no moving parts. International drinking water approvals. Degree of protection IP68 (Type 6P enclosure).

  • Transmitter features

    Safe operation – no need to open the device due to display with touch control, background lighting. Time-saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Transmitter housing made of durable polycarbonate or aluminium. WLAN access.

  • Nominal diameter range

    DN 25 to 2000 (1 to 78")

  • Wetted materials

    Liner: Polyurethane; Hard rubber
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum

  • Measured variables

    Volume flow, conductivity, mass flow

  • Max. measurement error

    Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)

    Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec

  • Measuring range

    9 dm³/min to 110 000 m³/h (2.5 gal/min to 700 Mgal/d)

  • Max. process pressure

    PN 40, Class 300, 20K

  • Medium temperature range

    Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
    Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)

  • Ambient temperature range

    Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
    Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)

  • Sensor housing material

    DN 25 to 300 (1 to 12"): AlSi10Mg, coated
    DN 25 to 2000 (1 to 78"): Carbon steel with protective varnish
    Sensor connection housing (standard): AlSi10Mg, coated
    Sensor connection housing (option): Polycarbonate

  • Transmitter housing material

    Polycarbonat; AlSi10Mg, coated

  • Degree of protection

    Compact version: IP66/67, type 4X enclosure
    Sensor remote version (standard): IP66/67, type 4X enclosure
    Sensor remote version (option): IP68, type 6P enclosure, with protective varnish
    according to EN ISO 12944 C5‐M/Im1/Im2/Im3
    Transmitter remote version: IP66/67, Type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display, web browser and operating tools possible

  • Outputs

    3 ouputs:
    0‐20 mA/4‐20 mA HART (active)
    Pulse/frequency/switch output (passive)
    Pulse/frequency output (passive)
    Switch output (passive)

  • Inputs

    Status input

  • Digital communication

    HART, PROFIBUS DP, EtherNet/IP, Modbus RS485

  • Power supply

    AC 100…240 V / AC/DC 24 V

  • Hazardous area approvals

    cCSAus

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
    Custody transfer according to MI‐001 or OIML R49 (optional class I in combination with 0DN inlet run)

  • Pressure approvals and certificates

    CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    Drinking water approval: ACS, KTW/W270, NSF 61, WRAS BS 6920

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
  • 45
    • Nr 45 Order code 71228789

      Kit connection terminals, Promag 400(C)

      (C)= generatie index C. Bestaat uit: Aansluitklem 3-Pol stempel 1,2, Aansluitklem 2-Pol stempel A, B, Aansluitklem 4-Pol stempel 20-23, Aansluitklem 4-Pol stempel 24-26.

  • 40
    • Nr 40 Order code 71228790

      Kit connec. board, D/L/W, remote,electr.

      Gebruik: Promag 400(C) met sensor D/L/W. (C)= generatie index C.

  • 44
    • Nr 44 Order code 71228795

      Kit connec. board, L/W, remote, sensor

      Gebruik: Promag 400(C) met sensor L/W. (C) = generatie index C.

  • 39
    • Nr 39 Order code 71185788

      Kit T-DAT, Promass 100

      Gebruik: Promag / Promass 100/300/500, 500 digitaal, Prosonic Flow E 100, Promag 400 (C). (C) = opwekkingsindex C.

  • 30
    • Nr 30 Order code XPD0014-

      Electronic Promag 400 Index C

      Complete main electronic module or power supply, I/O-board and amplifier as individual boards. Complete main electronic module contains: Power supply, I/O-board, amplifier, board carrier, terminal connection, ribbon cable, installation marterial. Individual boards contains: Installation marterial, Power supply incl. terminal connection/ I/O-board incl. terminal connection/ Amplifier incl. ribbon cable.

  • 50
  • 30
    • Nr 30 Order code XPD0040-

      Electronic Promag 400 Index C update

      Compleet belangrijkste elektronische module of voeding, I/O-board met versterker als individuele boards. Compleet belangrijkste elektronische module bevat: Voeding, I/O-board, versterker, board carrier, terminal-verbinding, lint kabel, installatie marterial. Individuele boards bevat: Installatie marterial, Voeding incl. terminal aansluiting/I/O- board incl. terminal verbinding en Versterker incl. lintkabel.

  • 20
    • Nr 20 Order code 71228788

      Kit cover, Promag 400(C)

      (C)= generatie index C. Bestaat uit: Complete plastic deksel, O-ring 196,44 x 3,53 VMQ 2x scharnier L=58mm plastic

    • Nr 20 Order code 71384170

      Kit cover, alu,Promag 400(C),500 digital

      Gebruik: Promag 400(C)= generatie-index C, Promag / Promass 500 digitaal, zenderbehuizing Alu. Bestaat uit: dekking Alu compleet inbegrepen O-ring 196,44x3,53 VMQ, standaard en -50°C/-58°F, draad met schroefslot 1,5x150

  • 24
    • Nr 24 Order code 71228796

      Kit cover, remote, Alu

      Gebruik: Promag 400(C)= generatie index C, Promag 500, Promass/Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: afdekking Alu, O-Ring 113,90x3,53 HNBR.

    • Nr 24 Order code 71188176

      Kit Cover gasket, sensor L/W, IP68

      Gebruik: Promag 400/800, Promag 500, sensoraansluiting behuizing. Bestaat uit: deksel geplastificeerd, O-ring 91,67 x 3,53 FKM.

  • 25
    • Nr 25 Order code 71278077

      Kit 10 afdichtingsring, polycarbonaat

      Gebruik: Promag 400(C), 500 digitaal met polycarbonaat behuizing. (C)= generatie-index C. Bestaat uit: 10x O-Ring 196,44x3,53 VMQ.

    • Nr 25 Order code 71278078

      Kit 10 cover gasket, alu, 400(C)

      Gebruik: Promag 400(C)= generatie index C, Promag/Promass 500 digitale, transmitterbehuizing Alu, Ex. Bestaat uit: 10x O-Ring 196,44x3,53 VMQ, verzuim en -50°C/-58°F.

  • 72
    • Nr 72 Order code 71188179

      Kit 10 cover gasket, sensor L/W, IP68

      Gebruik: Promag 400/800, Promag 500, sensoraansluiting behuizing. Bestaat uit: 10x O-ring 91,67x3,53 FKM.

  • 71
    • Nr 71 Order code 71228793

      Kit housing gasket, D/L/W,compact,400(C)

      Gebruik: Promag 400(C) met sensor D/L/W. (C)= generatie index C. Bestaat uit: EPDM voor huisvesting/sensor D/L/W. O-ring 29,87 x1,78 HNBR voor sensor- plug L/W.

  • 73
    • Nr 73 Order code 71228798

      Kit housing gaskets, remote, Alu

      Gebruik: Promag 400(C)= generatie index C, Promag 500, Promag 500 digitaal, sensoraansluiting behuizing. Bestaat uit: O-Ring 113,90x3,53 HNBR voor dekking, pakking EPDM voor behuizing/sensor L/P/W, O-Ring 29,87x1,78 HNBR voor sensor stekker.

  • 12
    • Nr 12 Order code 71228794

      Kit housing parts, D/L/W, compact,400(C)

      Gebruik: Promag 400(C) met sensor D/L/W. (C)= generatie index C. Bestaat uit: 4x schroef M5X18 hex cap DIN912 pla, 4x veerring M5 DIN7980 st.pla, voor behuizing/ sensor.

  • 15
  • 17
  • 15
  • 17
  • 15
  • 17
  • 15
  • 17
  • 15
  • 13
    • Nr 13 Order code 71276494

      Kit securing clamp, screw

      Gebruik: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Sensorhuis: Promag 400 (C), (C)= opwekkingsindex C, Promag / Promass 500, Promag / Promass 500 digitaal. Bestaat uit: afdekklem, schroef M4x16.

    • Nr 13 Order code 71276495

      Kit screw sealing, transm./sensor, alu

      Gebruik: Transmitterbehuizing: CNGmass, LPGmass, LNGmass, Prosonic Flow E Heat, Sensorhuis: Promag 400 (C), (C) = opwekkingsindex C. Bestaat uit: afdekklem, schroefafdichting M4x16.

    • Order code 71279174

      Kit sealing ring, sensor, polycarbonate

      Usage: Sensor housing polycarbonate: Promag 400(C). (C) = generation index C. Consists of: Sealing ring 1.4404.

    • Order code 71279175

      Kit screw sealing, transm., 400(C)

      Usage: Transmitter housing: Promag 400(C), (C) = generation index C. Consists of: Screw sealing M4x35.

    • Order code 50093681

      PNG 2 wisselelektroden PMAG F/W 4435

  • 82
    • Nr 82 Order code 71228792

      Kit display protection, Promag 400(C)

      Gebruik: Promag 400(C) = generatie index C, Promag/Promass 500 digitale, transmitterbehuizing. Bestaat uit: beeldscherm bescherming 1.4301, installatiemateriaal.

    • Order code 5X4CXX-

      Transmitter/ ombouwkit Promag 400

      Dezelfde behuizing voor compacte/afstandsuitvoering. Corrosiebestendige transmitter uitvoering. Met geïntegreerde webserver Ombouwkit: Voor de conversie van een reeds bestaande Promag naar de nieuwe generatie apparaten of naar een andere apparaatversie. Bestaat uit alle benodigde conversiedelen.

    • Order code DK5005-

      Transmitter 400, mounting kit

    • Order code DK5CA-

      Kabel voor separate uitv. PROMAG 50/53

      10/50/51/53/55/400/800 1 set bestaat uit 1 spoelkabel en 1 signaal kabel

    • Order code DK5GD-

      Promag, aardingsring/bescherm ring

      Één enkele aardingsring

    • Order code DK5GC-

      Promag L/W/P/S,E, grounding cable kit

      kit inclusief 2 kabels

    • Order code XPRFID-

      Spare RFID TAG

      Bestaat uit: RFID-tag, het bevestigen draad, krimp mouw.