Flowmeter with hygienic design, highest repeatability and an ultra-compact sensor. For demanding dosing and filling applications.
Sensor features
High process safety – high measuring accuracy and repeatability in shortest filling time. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts. Wetted materials CIP, SIP cleanable. Nominal diameter: DN 4 to 25 (¹⁄₈ to 1"). Measuring device conform to FDA.
±0.25 % o.r. ± 1 to 4 m/s (3.3 to 13 ft/s) ±0.5 % o.r. ± 1 mm/s (0.04 in/s) ±5 % o.r.
Measuring range
0.14 to 1.66 l/s (0.035 to 0.44 gal/s)
Max. process pressure
PN 16
Medium temperature range
Seal material EPDM: –20 to +130 °C (–4 to +266 °F) Seal material Silicone: –20 to +130 °C (–4 to +266 °F) Seal material Viton: 0 to +150 °C (+32 to +302 °F)
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
Sensor housing material
1.4308 (304)
Transmitter housing material
1.4308 (304)
Degree of protection
IP66/67, type 4X enclosure
Display/Operation
No local Operation Configuration via operating tools possible
Outputs
Pulse/frequency/switch output (passive)
Inputs
None
Digital communication
Modbus RS485
Power supply
DC 20 to 30 V
Hazardous area approvals
ATEX, IECEx, cCSAus
Product safety
CE
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc.to ISO/IEC 17025) NTEP