-
Online seminar
pH/ORP transmitter
Liquisys CPM253
Compact field device for all industries
Liquisys CPM253 is a standard pH/ORP transmitter for all analog and digital Memosens sensors. It improves your operational safety thanks to continuous plausibility, process and sensor checks. Select from numerous hardware and software modules, such as relays or fieldbus communication, to adapt it exactly to your measuring task. This modularity also allows you to upgrade the transmitter at any time. A simple menu and two-point calibration make configuration and operation fast and easy.
-
Eenvoudige producten
- Gemakkelijk te selecteren, installeren en gebruiken
Technische topkwaliteit
Eenvoud
-
Standaardproducten
- Betrouwbaar, robuust en onderhoudsarm
Technische topkwaliteit
Eenvoud
-
Gespecialiseerde producten
- Ontworpen voor veeleisende applicaties
Technische topkwaliteit
Eenvoud
Variabel
FLEX selectie | Technische topkwaliteit | Eenvoud |
---|---|---|
Fundamental selectie Voldoe aan uw basismeetvoorwaarden |
Technische topkwaliteit
|
Eenvoud
|
Lean selectie Beheers eenvoudig uw belangrijkste processen |
Technische topkwaliteit
|
Eenvoud
|
Extended selectie Optimaliseer uw processen met innovatieve technologieën |
Technische topkwaliteit
|
Eenvoud
|
Xpert selectie Beheers uw meest uitdagende applicaties |
Technische topkwaliteit
|
Eenvoud
Variabel |
-
Overzicht specificaties
-
Input
One-channel-transmitter
-
Output
0/4-20mA, Hart, Profibus.
-
Ingres protection
No
-
Snelle selectie
Individuele configuratie
-
Voordelen
More operational safety: Continuous process check system, customized alarm configuration, proven Memosens interface for reliable sensor connection.
Reliable self-monitoring: Sensor check system for pH glass and reference, calibration plausibility check.
...
-
Toepassingsgebied
The Liquisys CPM253 transmitter works with all pH/ORP glass and ISFET sensors in non-hazardous areas, for example in these industries and their utilities:
Chemicals
Food & Beverages
Power & Energy
Water & Wastewater
Primaries & Metal
Liquisys CPM253...
Documenten / handleidingen / software
-
Liquisys M CPM223/253
Technical Information
pH/ORP measurement
Technische informatie (TI) -
Technical Information CCM 223/
Measurement of chlorine / chlorine dioxide / total chlorine
Transmitter for chlorine sensorsTechnische informatie (TI) -
Operating Instructions Liquisys M CXM223/253 HART
Field Communication with Liquisys M CXM223/253
Inbedrijfsstellingsvoorschriften (BA) -
Operating Instructions Liquisys M CXM223/253 PROFIBUS
Field Communikation for Liquisys M CXM223/253
Inbedrijfsstellingsvoorschriften (BA) -
Liquisys M CPM223/253
Operating Instructions
Transmitter
Inbedrijfsstellingsvoorschriften (BA) -
Ex-safety instructions CXM2X3
Safety instructions for electrical apparatus for explosion-hazardous
areas as per EC Directive 94/9/EC (ATEX)Ex Veiligheidsinstructies (XA) -
Installation of M 12 plug
Special Documentation Installation of M 12 plug
CPM253 / COM253 / CLM253 / CUM253Speciale Documentatie (SD) -
Instructions for service kits Liquisis M
Special documents
Instructions for service kits Liquisis M / CPM253 / CLM253 / COM253 /
CUM253Speciale Documentatie (SD) -
Additional information for CSA Liquisys
Additional information for CSA Liquisys
Speciale Documentatie (SD) -
Simatic PDM HART Package 1.14.00
Manufacturer Information includes PDM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.14.00Fabrikanten Informatie (MI) -
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.08.00Fabrikanten Informatie (MI) -
AMS FOUNDATION fieldbus Package V1.06.00
Manufacturer Information includes AMS - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.06.00Fabrikanten Informatie (MI) -
Simatic PDM PROFIBUS Package V1.12.00
Manufacturer Information includes PDM - Device List, Release Notes –
PROFIBUS
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Fabrikanten Informatie (MI) -
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Fabrikanten Informatie (MI) -
PRM FOUNDATION fieldbus Package V1.05.00
Manufacturer Information includes PRM - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.05.00Fabrikanten Informatie (MI) -
pH 測定セレクションガイド
産業プロセスにおける pH 測定
Competentie Brochure (CP)08/15Japans -
CP00010C pH measurement in industrial processes for US market
Selection and engineering guide for your industry and application
Competentie Brochure (CP)04/15Engels -
Measurement and control aspect of pH using inductively coupled with
bidirectional Memosens technology in flue gas desulfurization process
White Paper CP971C pH measurement and control in a power utility is an
integral part of process. The scrubber efficiency is highlydependent on
the pH. Numerous opportunities were revealed for saving time, as well as
the cost and materials in power plants. In afossil fuel power plant,
the
chemical energy stored in coal, oil, natural gas, shale oil, oxygen and
air
is converted into thermal, mechanical and finally into electrical
energy. In
other words, water is heated to steam, which spins a steam turbine. The
steam turbine drives an electrical generator.Competentie Brochure (CP)04/11Engels -
pH-Messung in Industrieprozessen
Auswahl- und Engineering-Hilfe für verschiedene Industriebranchen und
ApplikationenCompetentie Brochure (CP)03/20Duits -
pH measurement in industrial processes
Selection and engineering guide for different industries and
applicationsCompetentie Brochure (CP)02/20Engels -
CP01202C pH Sensors:Calibrate, clean, perform a calibration check
or...?
This white paper will address
Knowing when to do a pH sensor calibration versus a calibration
check
How to properly clean a pH sensor
How to perform a pH sensor calibration
A decision tree for step by step guidanceCompetentie Brochure (CP)02/12Engels -
BAUMANN FEDERN - Modernisierte Abwasserbehandlung
Modernisierung der EMSR-Technik in der Abwasservorbehandlung
Case Studie (CS)03/14fr -
Liquisys CPM253
pH/Redox- und Temperatur Messumformer
Tender tekst12/16Duits -
Liquisys-M CPM253
1 pH/Redox and temperature transmitter
Tender tekst09/05Engels -
GSD Single, GSD_EH_DP_AN_Liquisys_0x1520_V02_04_DPLIB, 14.04.2014 (Analys
is, Liquisys M, 0x1520)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.04.00Language neutral -
GSD Single, GSD_EH_PA_AN_Liquisys_0x1516_V02_00_PALIB, 22.04.2014 (Analys
is, Liquisys M, 0x1516)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.00.00Language neutral -
DTM Single, LiquisysM_CPM2x3_PA_V2_30___V2_31, 20.10.2020 (Analysis, Liquisys M, 0x1516)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, LiquisysM_CPM2x3_DP_V2_30___V2_31, 28.10.2020 (Analysis, Liquisys M, 0x1520)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, LiquisysMPH_CPM2x3_V2_50, 26.10.2020 (Analysis, Liquisys M, 0x0091)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
Liquisys Chlorine, Liquisys Conductivity, Liquisys Oxygen, Liquisys pH/ORP
Productcode: CCM223-, CCM253-, CLM223-, CLM253-, COM223-, COM253-, CPM223-, CPM253-
verklaring Number: EC_00575_01.17EU DeclarationDuits , Engels , fr -
TopHit, Sensor, PuriSys, OrbiSint, OrbiPore, OrbiPac, Memosens, Liquisys pH/ORP, Liquisys Oxygen, Liquisys Chlorine, Liquiline M, Liquiline, CeraTex, Ceramax, CeraLiquid, CeraGel
Productcode: CPS47D-, CPS471D-, CPS471-, CPS441D-, CPS441-, CPS42D-, CPS42-, CPS41E-, CPS41D-, CPS41-, CPS341D-, CPS31D-, CPS31-, CPS171D-, CPS16D-, CPS491-, CPS491D-, CPS64-, CPS71-, CPS71D-, CPS71E-, CPS72-, CPS72D-, CPS76D-, CPS77D-, CPS91-, CPS91E-, CPS92-, CPS92D-, CPS96D-, CPS97D-, CCM223-, CCM253-, CM14-, CM42-, CM442-, CM442R-, CM444-, CM444R-, CM448-, CM448R-, CM44P-, CM72-, CM82-, COM223-, COM223F-, COM253-, COM253F-, CPF201-, CPF81-, CPF81D-, CPF82-, CPF82D-, CPM223-, CPM253-, CPS11-, CPS11D-, CPS11E-, CPS12-, CPS12D-, CPS12E-, CPS13-
Regio: Russia (TR CU)
Keuringsinstantie: EAC
Keurnummer: EAEC D-DE.AD07.B.01363/19MiscellaneousRussisch -
TopHit, Sensor, PuriSys, OrbiSint, OrbiPore, OrbiPac, Memosens, Liquisys pH/ORP, Liquisys Oxygen, Liquisys Chlorine, Liquiline M, Liquiline, CeraTex, Ceramax, CeraLiquid, CeraGel
Productcode: CPS491-, CPS47D-, CPS471D-, CPS471-, CPS441D-, CPS441-, CPS42D-, CPS42-, CPS41E-, CPS41D-, CPS41-, CPS341D-, CPS31D-, CPS31-, CPS171D-, CPS491D-, CPS64-, CPS71-, CPS71D-, CPS71E-, CPS72-, CPS72D-, CPS76D-, CPS77D-, CPS91-, CPS91D-, CPS91E-, CPS92-, CPS92D-, CPS96D-, CPS97D-, CPS16D-, CCM223-, CCM253-, CM14-, CM42-, CM442-, CM442R-, CM444-, CM444R-, CM448-, CM448R-, CM44P-, CM72-, CM82-, COM223-, COM223F-, COM253-, COM253F-, CPF201-, CPF81-, CPF81D-, CPF82-, CPF82D-, CPM223-, CPM253-, CPS11-, CPS11D-, CPS11E-, CPS12-, CPS12D-, CPS12E-, CPS13-
Regio: Russia (TR CU)
Keuringsinstantie: EAC
Keurnummer: EAEC RU D-DE.AD07.B.01362/19MiscellaneousRussisch -
Liquisys pH/ORP, Mycom S, MyPro
Productcode: CPM153-, CPM223-, CPM253-, CPM431-
Regio: Russia (GOST)
Keuringsinstantie: Rosstandart
Keurnummer: DE.C.31.004.A_39878MetrologyRussisch -
Liquisys pH/ORP, Mycom S, MyPro
Productcode: CPM153-, CPM223-, CPM253-, CPM431-
Regio: Russia (GOST)
Keuringsinstantie: Rosstandart
Keurnummer: DE.C.31.004.A_39878MetrologyRussisch -
Liquisys Chlorine, Liquisys Conductivity, LIQUISYS M, Liquisys Oxygen, Liquisys Turbidity, SmarTec S
Productcode: CUM253-, CUM223-, CPM253-, CPM223-, COM253F-, COM253-, COM223F-, COM223-, CLM253-, CLM223F-, CLM223-, CLD134-, CCM253-, CCM223-
Regio: Canada, USA
Keuringsinstantie: CSAOrdinary Location Product SafetyEngels
Accessoires / Spare parts
-
-
Nr 410 Order code 51501068
KIT CXM253 housing cover
-
-
-
Nr 335 Order code 71071446
Kit CxM253: Front foil + 6 key lifters
-
-
-
Nr 330,340,45 Order code 51501073
CXM253 moederprint met binnenbehuizing
-
-
-
Order code 51502184
M12 VELDBUSSTEKKER, PAST IN PG16
-
-
-
Nr 400 Order code 51501072
CXM253 behuizing onderzijde
-
-
-
Nr 430 Order code 51501069
CPM253 scharnierset voor deksel
-
-
-
Nr 490 Order code 51501087
CXM2X3 aardings strip
-
-
-
Nr 470 Order code 51501079
CPM253 konnektor voedingsspanning
-
-
-
Order code 50086842
Mastmontageset voor LIQUISYS
voor montage van de veld-transmitters op horizontale en verticale pijpen max. diameter 60 mm Materiaal: roestvrij staal V2A
-
-
-
Nr 310 Order code 51501074
CXM253 displaykabels
-
-
-
Nr 40 Order code 51501081
CPM2X3 uP board (1 stroomuitgang)
-
Nr 40 Order code 51501083
CPM2X3 uP board(1 stroomuitg. met HART)
-
Nr 40 Order code 51501082
CPM2X3 uP board (2 stroomuitgangen)
-
Nr 40 Order code 51501084
CPM2X3 uP board (2 stroomuitg. met HART)
-
Nr 40 Order code 51501085
CPM2x3 hoofdprint Profibus PA
-
Nr 40 Order code 51502503
CPM2X3 Centraalmodu Profibus DP
-
Nr 40 Order code 71134724
Kit CPM2x3: Central mod. PB DP; H/W 2.1x
Inhoud: 1x Centrale module Profibus DP Module naam: LSCP-DP qualifired van H/W 2,10
-
-
-
Nr 290 Order code 71134732
Kit CxM2x3: Relay mod. for PBDP; H/W2.1x
Inhoud: 1x Relaismodule Profibus DP 2x relais, 1x Stroomingang DP- aansluiting gekwalificeerd vanaf H/W 2,10
-
-
-
Nr 230 Order code 51507096
CPM2X3 pH inagnsmodule MKP2
-
Nr 230 Order code 51518244
-
Nr 230 Order code 51514966
KIT MKD1 Memosens-Transmittermodule cpl.
digital data transmission for Memosens
-
-
-
Nr 10 Order code 51500317
CxM2x3 voeding AC
-
-
-
Nr 20 Order code 51500318
-
-
-
Order code 51500320
CxM2x3 relaismodule (2 relais)
Upgrade of LIQUISYS-M basis versie 2 potentiaal vrije wissel contacten
-
-
-
Nr 290 Order code 51511446
KIT CXM2X3 relay mod. 2rel / CSA
Upgrade van LIQUISYS-M basis versie door 2 potentiaalvrije wisselcontacten.
-
-
-
Nr 300 Order code 51500321
CxM2x3 4 RELAISPRINT MET CHEMOCLEAN
Let op Fabriek heeft serienummer nodig !
-
Nr 300 Order code 51511447
KIT CXM2X3 relay mod. 4rel / CSA
-
-
-
Nr 290 Order code 51504304
2-relaiskaart met stroomingang 4-20mA
Upgrade van Liquisys M in basisversie met 2 contacten en stroomingang 4-20 mA
-
-
-
Nr 300 Order code 51504305
4 relaisprint met stroomingang 4-20 mA
Upgrade van Liquisys M basis versie met 4 relais en stroomingang 4-20 mA
-
-
-
Nr 999 Order code 51501071
CxM2x3 pH/mV aansluitklemmen
-
-
-
Order code 51500385
CxM2x3 PLUSPAKKET KIT
Upgrade of LIQUISYS-M basic version (parameter pH,Cond.,Tu,CL,O2 (WX to WS)) to S-version (plus-package). Serial number of instrument needed.
-
Order code 51500963
UPGRADE CLEANING VOOR LIQUISYS-M
Upgrade of LIQUISYS-M basic version by cleaning functionality (Chemoclean) (serial number of instrument needed). If not yet installed, a 4-relay board must be ordered separately (51500321).
-
-
Voorganger