This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Predecessor
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
Product headline
The single‐tube flowmeter for smallest quantities with custody transfer functionality. Measuring accurately smallest quantities of liquids and gases for continuous process control.
-
Sensor features
Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Nominal diameter: DN 2 to 4 (¹⁄₁₂ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi).
-
Transmitter features
Quality – designed for custody transfer; featuring worldwide recognized metrological approvals. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 2 to 4 (¹⁄₁₂ to ¹⁄₈")
-
Wetted materials
Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 450 kg/h (0 to 16.5 lb/min)
-
Max. process pressure
PN 40, Class 300, 20K, 400 bar (5800 psi)
-
Medium temperature range
–50 to +200 °C (–58 to +392 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive),
phase‐shifted pulse
Relay -
Inputs
1 modular input: status
-
Digital communication
HART
Modbus RS485 -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI, EAC
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, custody transfer, CRN, 3-A
-
Product safety
CE, C-tick, EAC marking
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Custody transfer approvals: MI-002 (gas), MI-005 (liquid) , PTB 7.251 (gas) -
Pressure approvals and certificates
CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A
-
Product headline
The single‐tube flowmeter for smallest quantities with custody transfer functionality. Measuring accurately smallest quantities of liquids and gases for continuous process control.
-
Sensor features
Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Nominal diameter: DN 2 to 4 (¹⁄₁₂ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi).
-
Transmitter features
Quality – designed for custody transfer; featuring worldwide recognized metrological approvals. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 2 to 4 (¹⁄₁₂ to ¹⁄₈")
-
Wetted materials
Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 450 kg/h (0 to 16.5 lb/min)
-
Max. process pressure
PN 40, Class 300, 20K, 400 bar (5800 psi)
-
Medium temperature range
–50 to +200 °C (–58 to +392 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive),
phase‐shifted pulse
Relay -
Inputs
1 modular input: status
-
Digital communication
HART
Modbus RS485 -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, custody transfer, CRN, 3-A
-
Product safety
CE, C-tick, EAC marking
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Custody transfer approvals: MI-002 (gas), MI-005 (liquid), PTB 7.251 (gas) -
Pressure approvals and certificates
CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A
-
Characteristic / Application
Coriolis mass flowmeter for custody transfer application.
-
Ambient temperature
-20...+65°C
(-4...+140°F) -
Process temperature
-50...+200°C
(-58...+392°F) -
Process pressure
PN 16...400
Cl 150...600
JIS 10...63K -
Wetted parts
904L/1.4539
Alloy C-22/2.4602 -
Output
4...20mA
Pulse/Frequency (10KHz, 90° phase shifted, active/passive) -
Certificates / Approvals
ATEX
FM
CSA
TIIS
-
Product headline
The single‐tube flowmeter for smallest quantities with custody transfer functionality. Measuring accurately smallest quantities of liquids and gases for continuous process control.
-
Sensor features
Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Nominal diameter: DN 2 to 4 (¹⁄₁₂ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi).
-
Transmitter features
Quality – designed for custody transfer; featuring worldwide recognized metrological approvals. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 2 to 4 (¹⁄₁₂ to ¹⁄₈")
-
Wetted materials
Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 450 kg/h (0 to 16.5 lb/min)
-
Max. process pressure
PN 40, Class 300, 20K, 400 bar (5800 psi)
-
Medium temperature range
–50 to +200 °C (–58 to +392 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive),
phase‐shifted pulse
Relay -
Inputs
1 modular input: status
-
Digital communication
HART
Modbus RS485 -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI, EAC
-
Product safety
CE, C-tick, EAC marking
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR Custody transfer approvals: MI-002 (gas), MI-005 (liquid) , PTB 7.251 (gas)
-
Pressure approvals and certificates
CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A
-
-
Technical Information (TI)
Proline Promass 84A Technical Information
-
Technical Information (TI)
English version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System
The single-tube system for highly accurate measurement of very small
flows for custody transferEN 15/10/201201/11/200901/09/200701/12/200615/03/2005Language:
English
Version:
15/10/2012
File size:
955.9 KB
File name:
TI00068DEN_1312.pdf
-
-
-
Operating Instruction (BA)
Istruzioni di funzionamento Proline Promass 84 Modbus RS485
-
Operating Instruction (BA)
Italian version - 10/2012New version available in EnglishSistema di misura di portata massica Coriolis
per uso fiscaleEN 15/10/201201/11/200801/12/2006Language:
Italian
Version:
15/10/2012
File size:
2.4 MB
File name:
BA00129DIT_1412.PDF
-
-
-
Operating Instruction (BA)
Proline Promass 84 Описание функций прибора
-
Operating Instruction (BA)
Russian version - 09/2008New version available in EnglishОснованная на использовании эффекта Кориолиса система
измерения массового расхода для целей коммерческого учетаEN 01/09/2008Language:
Russian
Version:
01/09/2008
File size:
2.2 MB
File name:
BA110DRU.pdf
-
-
-
Operating Instruction (BA)
Sistema di misura di portata massica Coriolis
-
Operating Instruction (BA)
Italian version - 11/2008New version available in EnglishProline Promass 84 MODBUS RS485
EN 01/11/200801/12/2006Language:
Italian
Version:
01/11/2008
File size:
1.8 MB
File name:
BA130DIT_11.08.pdf
-
-
-
Operating Instruction (BA)
Proline Promass 84 HART Betriebsanleitung
-
Operating Instruction (BA)
Russian version - 10/2012New version available in EnglishCoriolis-Massedurchfluss-Messsystem für den eichpflichtigen Verkehr.
(Beschreibung der Gerätefunktionen in separater Dokumentation)EN 15/10/2012Language:
Russian
Version:
15/10/2012
File size:
2.2 MB
File name:
BA00109DRU_1412.pdf
-
-
-
Short Instruction (KA)
Proline Promass 84 Brief Operating Instructions
-
Short Instruction (KA)
English version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System
EN 15/10/201231/12/201101/07/2007Language:
English
Version:
15/10/2012
File size:
671.5 KB
File name:
KA00025DEN_1412.pdf
-
-
-
Installation Instructions (EA)
EA Replacing cover and O-ring
-
Installation Instructions (EA)
English version - 10/2024New version available in EnglishProline 10, 23, 50, 51, 53, 55, 400, 800, 40, 80, 83, 84, 8ME, 8FF, 8FE
,8CM, 90, 91, 92, 93, 65, 72, 73EN 15/10/202401/10/2018Language:
English
Version:
15/10/2024
File size:
797.3 KB
File name:
EA00098DA2_1624-00.pdf
-
-
-
Installation Instructions (EA)
Replacing T-DAT Installation Instructions
-
Installation Instructions (EA)
English version - 11/2018New version available in EnglishPromag 23, 53, 55, Promass 83, 84, 8WF, 8ME, Cubemass DCI 8CN, CNGmass
DCI 8DF, Prosonic Flow 91, 93, t-mass 65EN 15/11/2018Language:
English
Version:
15/11/2018
File size:
481.6 KB
File name:
EA00072DA2_1418.pdf
-
-
-
Installation Instructions (EA)
I/O-board, subprint, screening sheed Installation Instructions
-
Installation Instructions (EA)
English version - 05/2017New version available in EnglishPromag 50, 51, 53, 55, Promass 40, 80, 83, 84, 8ME, Cubemass DCI 8CN,
CNGmass DCI 8DF, Prosonic Flow 90, 93, t-mass 65EN 01/05/201718/11/2011Language:
English
Version:
01/05/2017
File size:
350.6 KB
File name:
EA00062DA2_1517.pdf
-
-
-
Installation Instructions (EA)
Replacing amplifier board Installation Instructions
-
Installation Instructions (EA)
English version - 11/2018New version available in EnglishPromag 50, 51, 53, 55, Promass 40, 80, 83, 84, Cubemass DCI 8CN, CNGmass
DCI 8DF, Prosonic Flow 90, 93, t-mass 65EN 15/11/2018Language:
English
Version:
15/11/2018
File size:
393.9 KB
File name:
EA00064DA2_1518.pdf
-