Iron concentration in a liquid can be measured using the colorimetric measuring principle. This video shows what it is about and how this measuring principle works.

Colorimetric system for monitoring of drinking water, mineral water and process water

Liquiline System CA80FE offers precise, regulation-compliant online measurement. It supports you in controlling the iron content of drinking water, mineral water or source water for industrial processes. Like all Liquiline System analyzers, it enables plug & play of up to four Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning and the low reagent consumption reduce operating costs while advanced diagnostics with remote access ensure process safety.

  • Eenvoudige producten

  • Gemakkelijk te selecteren, installeren en gebruiken

Technische topkwaliteit

Eenvoud

  • Standaardproducten

  • Betrouwbaar, robuust en onderhoudsarm

Technische topkwaliteit

Eenvoud

  • High-end producten

  • Functioneel en uiterst doelmatig

Technische topkwaliteit

Eenvoud

  • Gespecialiseerde producten

  • Ontworpen voor veeleisende applicaties

Technische topkwaliteit

Eenvoud

Variabel

FLEX selectie Technische topkwaliteit Eenvoud
  • F
  • L
  • E
  • X

Fundamental selectie

Voldoe aan uw basismeetvoorwaarden

Technische topkwaliteit
Eenvoud
  • F
  • L
  • E
  • X

Lean selectie

Beheers eenvoudig uw belangrijkste processen

Technische topkwaliteit
Eenvoud
  • F
  • L
  • E
  • X

Extended selectie

Optimaliseer uw processen met innovatieve technologieën

Technische topkwaliteit
Eenvoud
  • F
  • L
  • E
  • X

Xpert selectie

Beheers uw meest uitdagende applicaties

Technische topkwaliteit
Eenvoud

Variabel

  • Overzicht specificaties

    • Measurement range

      0.05 to 2 mg/l Fe
      0.1 to 5 mg/l Fe
      0.1 to 5 mg/l with dilution function to maximum 2.0 to 100 mg/l Fe

    • Process temperature

      4 to 40 °C (39.2 to 104 °F)

    • Process pressure

      At atmospheric pressure, < 0.2 bar

please wait Loading alternative products

Snelle selectie

Kies uit één van de voorgestelde opties
Verkoopprijs
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

of

Individuele configuratie

Ga verder met uw keuze uit alle mogelijke opties
  • Voordelen

    • Compliance with standard ferrozine method ensures direct comparability to lab measurements

    • Supports predictive maintenance by advanced diagnostics

    • Reduced operating costs through automatic calibration and cleaning as well as low reagent consumption

    • ...

  • Toepassingsgebied

    Liquiline System CA80FE monitors:

    • Iron content in drinking water and mineral water

    • Residual iron after precipitation, flocculation and filtration processes

    • Process water containing diluted iron

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Colorimetric

  • Characteristic

    Process analyzer for iron in aqueous solutions
    Comply with standard colorimetric measuring principle, ferrozine method

  • Size

    Housing (open version):

    793 x 530 x 417 mm

    31.22 x 20.87 x 16.42 in


    Housing (closed version):

    793 x 530 x 463 mm

    31.22 x 20.87 x 18.23 in


    Housing with base:

    1723 x 530 x 463 mm

    67.83 x 20.87 x 18.23 in

  • Design

    Open design, cabinet and stand housing
    High-Performance plastic ASA-PC, additional stand coated steel

  • Process temperature

    4 to 40 °C (39.2 to 104 °F)

  • Ambient temperature

    5 to 40 °C (41 to 104 °F)

    Outdoor version: - 20 to 40 °C (-4 to 104 °F)

  • Process pressure

    At atmospheric pressure, < 0.2 bar

  • Sample flow rate

    Min. 5 ml/min (0.17 fl.oz/min)

  • Consistency of the sample

    Suspended solids content
    Turbitity < 50 NTU, aqueous, homogenized

  • Application

    Monitoring of the iron content of potable water, mineral water and source water for industrial processes

  • Power supply

    100 to 120 VAC / 200 to 240 VAC ± 10%
    24 VDC ± 10%
    50 ± 1 or 60 ± 1,2 Hz

  • Output / communication

    2x 0/4 to 20 mA
    Webserver, Modbus, Ethernet/IP, Profibus DP

  • Input

    1 or 2 measuring channel
    1 to 4 digital sensor inputs for sensors with Memosens protocol (optional)

  • Measurement range

    0.05 to 2 mg/l Fe

    0.1 to 5 mg/l Fe

    0.1 to 5 mg/l with dilution function to maximum 2.0 to 100 mg/l Fe

  • Consumables

    Reagents and standard solutions CY80FE for the operation
    Regular maintenance is done with the parts of the maintenance kit CAV800

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification