Nitrite analyzer
Liquiline System CA80NO

Liquiline System CA80NO - Nitrite analyzer for drinking water, mineral water, wastewater ©Endress+Hauser
Liquiline System CA80NO nitrite analyzer with cooling for extended reagent lifetime ©Endress+Hauser

Nitrite concentration in a liquid can be measured using the colorimetric measuring principle. This video shows what it is about and how this measuring principle works.

Colorimetric system for monitoring of drinking water, mineral water or raw water for food production

Liquiline System CA80NO offers precise, regulation-compliant online measurement of nitrite. It supports you in meeting the specified limits in drinking water, mineral water or food production. Like all Liquiline System analyzers, it enables plug & play of up to four Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning and the low reagent consumption reduce operating and maintenance costs. Advanced diagnostics with remote access ensure process safety.

  • Voordelen

    • Compliance with standard colorimetric measuring principle - naphthylamine method - following ISO 6777 and DIN EN 26777 ensures comparability to lab measurements.

    • Reduced operating costs through automatic calibration and cleaning.

    • Simple maintenance: no...

  • Toepassingsgebied

    Liquiline System CA80NO supports you in keeping the strict nitrite limits for:

    • Drinking water

    • Mineral water

    • Raw water for food production

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Colorimetric

  • Characteristic

    Process analyzer for Nitrite in potable water

  • Size

    Cabinet:
    793 x 530 x 417 mm
    31.22 x 20.87 x 16.42 inch
    Stand housing:
    1693 x 530 x 417 mm
    66.65 x 20.87 x 16.42 inch

  • Design

    Open design, cabinet and stand housing
    High-Performance plastic ASA-PC, additional stand coated steel

  • Process temperature

    4 to 40 °C (39 to 104 °F)

  • Ambient temperature

    5 to 40 °C (41 to 104 °F)

  • Process pressure

    At atmospheric pressure, < 0.2 bar absolute

  • Sample flow rate

    Min. 5 ml/min (0.17 fl.oz/min)

  • Consistency of the sample

    Suspended solids content
    Turbitity < 50 NTU, aqueous, homogenized

  • Specials

    Easy upgrade to measuring station with up to four digital Memosens sensors
    Automatic calibration and cleaning
    User-configurable measuring, cleaning and calibration intervals
    Optional cooling module for standard solution
    2 channel version optional

    User-definable measuring ranges
    Modular design for easily extensible functionality

  • Application

    Limit value monitoring of nitrite for potable water and mineral water applications

  • Power supply

    100 to 120 VAC / 200 to 240 VAC ± 10%
    24 VDC ± 10%
    50 ± 1 or 60 ± 1,2 Hz

  • Output

    2x 0/4 to 20 mA
    Modbus RS485/TCP (optional)
    Ethernet (optional)
    Alarmrelay

  • Input

    1 or 2 measuring channel
    1 to 4 digital sensor inputs for sensors with Memosens protocol (optional)

  • Measurement range

    10 to 500 µg/l NO2-N
    0.1 to 1.0 mg/l NO2-N
    0.2 to 3.0 mg/l NO2-N

  • Consumables

    Reagents and standard solutions CY80NO as well as cleaner CY800 are necessary for the operation
    Regular maintenance is done with the parts of the maintenance kit CAV800

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification