Online seminar
pH/ORP transmitter
Liquisys CPM223
Compact panel device for all industries
Liquisys CPM223 is a standard pH/ORP transmitter for all analog and digital Memosens sensors. It improves your operational safety thanks to continuous plausibility, process and sensor checks. Select from numerous hardware and software modules, such as relays or fieldbus communication, to adapt it exactly to your measuring task. This modularity also allows you to upgrade the transmitter at any time. A simple menu and two-point calibration make configuration and operation fast and easy.
-
Eenvoudige producten
- Gemakkelijk te selecteren, installeren en gebruiken
Technische topkwaliteit
Eenvoud
-
Standaardproducten
- Betrouwbaar, robuust en onderhoudsarm
Technische topkwaliteit
Eenvoud
-
Gespecialiseerde producten
- Ontworpen voor veeleisende applicaties
Technische topkwaliteit
Eenvoud
Variabel
FLEX selectie | Technische topkwaliteit | Eenvoud |
---|---|---|
Fundamental selectie Voldoe aan uw basismeetvoorwaarden |
Technische topkwaliteit
|
Eenvoud
|
Lean selectie Beheers eenvoudig uw belangrijkste processen |
Technische topkwaliteit
|
Eenvoud
|
Extended selectie Optimaliseer uw processen met innovatieve technologieën |
Technische topkwaliteit
|
Eenvoud
|
Xpert selectie Beheers uw meest uitdagende applicaties |
Technische topkwaliteit
|
Eenvoud
Variabel |
-
Overzicht specificaties
-
Input
One-channel-transmitter
-
Output
0/4-20 mA, Hart, Profibus.
-
Ingres protection
IP65
-
Snelle selectie
Individuele configuratie
-
Voordelen
More operational safety: Continuous process check system, customized alarm configuration, proven Memosens interface for reliable sensor connection.
Reliable self-monitoring: Sensor check system for pH glass and reference, calibration plausibility check.
...
-
Toepassingsgebied
The Liquisys CPM223 transmitter works with all pH/ORP glass and ISFET sensors in non-hazardous areas, for example in these industries and their utilities:
Chemicals
Food & Beverages
Power & Energy
Water & Wastewater
Primaries & Metal
Liquisys CPM223...
Documenten / handleidingen / software
-
Liquisys M CPM223/253
Technical Information
pH/ORP measurement
Technische informatie (TI) -
Operating Instructions Liquisys M CXM223/253 PROFIBUS
Field Communikation for Liquisys M CXM223/253
Inbedrijfsstellingsvoorschriften (BA) -
Operating Instructions Liquisys M CXM223/253 HART
Field Communication with Liquisys M CXM223/253
Inbedrijfsstellingsvoorschriften (BA) -
Liquisys M CPM223/253
Operating Instructions
Transmitter
Inbedrijfsstellingsvoorschriften (BA) -
Ex-safety instructions CXM2X3
Safety instructions for electrical apparatus for explosion-hazardous
areas as per EC Directive 94/9/EC (ATEX)Ex Veiligheidsinstructies (XA) -
Instructions for service kits Liquisis M
Special documentation
Instructions for service kits Liquisis M / CPM223 / CLM223 / COM223 /
CUM223Speciale Documentatie (SD) -
Additional information for CSA Liquisys
Additional information for CSA Liquisys
Speciale Documentatie (SD) -
Simatic PDM PROFIBUS Package V1.12.00
Manufacturer Information includes PDM - Device List, Release Notes –
PROFIBUS
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Fabrikanten Informatie (MI) -
PRM FOUNDATION fieldbus Package V1.05.00
Manufacturer Information includes PRM - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.05.00Fabrikanten Informatie (MI) -
AMS FOUNDATION fieldbus Package V1.06.00
Manufacturer Information includes AMS - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.06.00Fabrikanten Informatie (MI) -
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.08.00Fabrikanten Informatie (MI) -
Simatic PDM HART Package 1.14.00
Manufacturer Information includes PDM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.14.00Fabrikanten Informatie (MI) -
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Fabrikanten Informatie (MI) -
pH 測定セレクションガイド
産業プロセスにおける pH 測定
Competentie Brochure (CP)08/15Japans -
CP00010C pH measurement in industrial processes for US market
Selection and engineering guide for your industry and application
Competentie Brochure (CP)04/15Engels -
Measurement and control aspect of pH using inductively coupled with
bidirectional Memosens technology in flue gas desulfurization process
White Paper CP971C pH measurement and control in a power utility is an
integral part of process. The scrubber efficiency is highlydependent on
the pH. Numerous opportunities were revealed for saving time, as well as
the cost and materials in power plants. In afossil fuel power plant,
the
chemical energy stored in coal, oil, natural gas, shale oil, oxygen and
air
is converted into thermal, mechanical and finally into electrical
energy. In
other words, water is heated to steam, which spins a steam turbine. The
steam turbine drives an electrical generator.Competentie Brochure (CP)04/11Engels -
pH-Messung in Industrieprozessen
Auswahl- und Engineering-Hilfe für verschiedene Industriebranchen und
ApplikationenCompetentie Brochure (CP)03/20Duits -
pH measurement in industrial processes
Selection and engineering guide for different industries and
applicationsCompetentie Brochure (CP)02/20Engels -
CP01202C pH Sensors:Calibrate, clean, perform a calibration check
or...?
This white paper will address
Knowing when to do a pH sensor calibration versus a calibration
check
How to properly clean a pH sensor
How to perform a pH sensor calibration
A decision tree for step by step guidanceCompetentie Brochure (CP)02/12Engels -
Liquisys CPM223
pH/Redox- und Temperatur Messumformer
Tender tekst12/16Duits -
GSD Single, GSD_EH_DP_AN_Liquisys_0x1520_V02_04_DPLIB, 14.04.2014 (Analys
is, Liquisys M, 0x1520)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.04.00Language neutral -
GSD Single, GSD_EH_PA_AN_Liquisys_0x1516_V02_00_PALIB, 22.04.2014 (Analys
is, Liquisys M, 0x1516)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.00.00Language neutral -
DTM Single, LiquisysM_CPM2x3_DP_V2_30___V2_31, 28.10.2020 (Analysis, Liquisys M, 0x1520)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, LiquisysM_CPM2x3_PA_V2_30___V2_31, 20.10.2020 (Analysis, Liquisys M, 0x1516)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, LiquisysMPH_CPM2x3_V2_50, 26.10.2020 (Analysis, Liquisys M, 0x0091)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
Liquisys pH/ORP
Productcode: CPM223-
verklaring Number: HE_01343_01.20
Specificatie van de fabrikant: RoHSManufacturer DeclarationEngels -
Liquisys Chlorine, Liquisys Conductivity, Liquisys Oxygen, Liquisys pH/ORP
Productcode: CCM223-, CCM253-, CLM223-, CLM253-, COM223-, COM253-, CPM223-, CPM253-
verklaring Number: EC_00575_01.17EU DeclarationDuits , Engels , fr -
TopHit, Sensor, PuriSys, OrbiSint, OrbiPore, OrbiPac, Memosens, Liquisys pH/ORP, Liquisys Oxygen, Liquisys Chlorine, Liquiline M, Liquiline, CeraTex, Ceramax, CeraLiquid, CeraGel
Productcode: CPS491-, CPS47D-, CPS471D-, CPS471-, CPS441D-, CPS441-, CPS42D-, CPS42-, CPS41E-, CPS41D-, CPS41-, CPS341D-, CPS31D-, CPS31-, CPS171D-, CPS491D-, CPS64-, CPS71-, CPS71D-, CPS71E-, CPS72-, CPS72D-, CPS76D-, CPS77D-, CPS91-, CPS91D-, CPS91E-, CPS92-, CPS92D-, CPS96D-, CPS97D-, CPS16D-, CCM223-, CCM253-, CM14-, CM42-, CM442-, CM442R-, CM444-, CM444R-, CM448-, CM448R-, CM44P-, CM72-, CM82-, COM223-, COM223F-, COM253-, COM253F-, CPF201-, CPF81-, CPF81D-, CPF82-, CPF82D-, CPM223-, CPM253-, CPS11-, CPS11D-, CPS11E-, CPS12-, CPS12D-, CPS12E-, CPS13-
Regio: Russia (TR CU)
Keuringsinstantie: EAC
Keurnummer: EAEC RU D-DE.AD07.B.01362/19MiscellaneousRussisch -
TopHit, Sensor, PuriSys, OrbiSint, OrbiPore, OrbiPac, Memosens, Liquisys pH/ORP, Liquisys Oxygen, Liquisys Chlorine, Liquiline M, Liquiline, CeraTex, Ceramax, CeraLiquid, CeraGel
Productcode: CPS47D-, CPS471D-, CPS471-, CPS441D-, CPS441-, CPS42D-, CPS42-, CPS41E-, CPS41D-, CPS41-, CPS341D-, CPS31D-, CPS31-, CPS171D-, CPS16D-, CPS491-, CPS491D-, CPS64-, CPS71-, CPS71D-, CPS71E-, CPS72-, CPS72D-, CPS76D-, CPS77D-, CPS91-, CPS91E-, CPS92-, CPS92D-, CPS96D-, CPS97D-, CCM223-, CCM253-, CM14-, CM42-, CM442-, CM442R-, CM444-, CM444R-, CM448-, CM448R-, CM44P-, CM72-, CM82-, COM223-, COM223F-, COM253-, COM253F-, CPF201-, CPF81-, CPF81D-, CPF82-, CPF82D-, CPM223-, CPM253-, CPS11-, CPS11D-, CPS11E-, CPS12-, CPS12D-, CPS12E-, CPS13-
Regio: Russia (TR CU)
Keuringsinstantie: EAC
Keurnummer: EAEC D-DE.AD07.B.01363/19MiscellaneousRussisch -
Liquisys pH/ORP, Mycom S, MyPro
Productcode: CPM153-, CPM223-, CPM253-, CPM431-
Regio: Russia (GOST)
Keuringsinstantie: Rosstandart
Keurnummer: DE.C.31.004.A_39878MetrologyRussisch -
Liquisys pH/ORP, Mycom S, MyPro
Productcode: CPM153-, CPM223-, CPM253-, CPM431-
Regio: Russia (GOST)
Keuringsinstantie: Rosstandart
Keurnummer: DE.C.31.004.A_39878MetrologyRussisch -
Liquisys Chlorine, Liquisys Conductivity, LIQUISYS M, Liquisys Oxygen, Liquisys Turbidity, SmarTec S
Productcode: CUM253-, CUM223-, CPM253-, CPM223-, COM253F-, COM253-, COM223F-, COM223-, CLM253-, CLM223F-, CLM223-, CLD134-, CCM253-, CCM223-
Regio: Canada, USA
Keuringsinstantie: CSAOrdinary Location Product SafetyEngels
Accessoires / Spare parts
-
-
Order code 51500320
CxM2x3 relaismodule (2 relais)
Upgrade of LIQUISYS-M basis versie 2 potentiaal vrije wissel contacten
-
-
-
Nr 290 Order code 51511446
KIT CXM2X3 relay mod. 2rel / CSA
Upgrade van LIQUISYS-M basis versie door 2 potentiaalvrije wisselcontacten.
-
-
-
Nr 300 Order code 51500321
CxM2x3 4 RELAISPRINT MET CHEMOCLEAN
Let op Fabriek heeft serienummer nodig !
-
Nr 300 Order code 71129943
Kit CxM2x3: realy modul 4 REL prot. coat
Upgrade of basic function of LIQUISYS-M with 4 dry changeover contacts eletronics with protection coating
-
Nr 300 Order code 51511447
KIT CXM2X3 relay mod. 4rel / CSA
-
-
-
Nr 290 Order code 51504304
2-relaiskaart met stroomingang 4-20mA
Upgrade van Liquisys M in basisversie met 2 contacten en stroomingang 4-20 mA
-
-
-
Nr 300 Order code 51504305
4 relaisprint met stroomingang 4-20 mA
Upgrade van Liquisys M basis versie met 4 relais en stroomingang 4-20 mA
-
-
-
Nr 10 Order code 51500317
CxM2x3 voeding AC
-
Nr 10 Order code 71129939
KIT CXM2X3 power supply AC prot.coating
CxM2x3 power supply 100/115/230 V AC eletronics with protection coating
-
-
-
Nr 20 Order code 51500318
-
-
-
Nr 330 Order code 51501075
CCM223 behuizing kompleet
-
-
-
Order code 51501076
CCM223 achter- en zijwand.
-
-
-
Nr 310 Order code 51502124
CXM223 Zijwand (10 stuks)
-
-
-
Nr 340 Order code 51502513
CXM223 aansluitraam achterkant Profib.DP
-
Nr 340 Order code 51501086
CxM223 Klemmenset vereffeningsklem
-
-
-
Nr 430 Order code 51501078
CxM2x3 aansluitklem voor uitgangsrelais
-
-
-
Nr 230 Order code 51507096
CPM2X3 pH inagnsmodule MKP2
-
Nr 230 Order code 51518244
-
Nr 230 Order code 51514966
KIT MKD1 Memosens-Transmittermodule cpl.
digital data transmission for Memosens
-
Nr 230 Order code 71129957
KIT MKD1 universal transm digital coat.
CPM2x3 MKD1 Transmitter module for Memosens communication eletronics with protection coating
-
-
-
Order code 51517035
Kit Memosens Module+CPS71D+CYK10
-
Order code 51517034
Kit Memosens Module+CPS11D+CYK10
-
Order code 71085858
Kit Memosens Module+CPF81D+CYK10
-
-
-
Nr 40 Order code 51501081
CPM2X3 uP board (1 stroomuitgang)
-
Nr 40 Order code 51501083
CPM2X3 uP board(1 stroomuitg. met HART)
-
Nr 40 Order code 71129949
KIT CPM2x3 central module I1HART coating
CPM2x3 central modul 1 x current output with HART eletronics with protection coating
-
Nr 40 Order code 51501082
CPM2X3 uP board (2 stroomuitgangen)
-
Nr 40 Order code 51501084
CPM2X3 uP board (2 stroomuitg. met HART)
-
Nr 40 Order code 51501085
CPM2x3 hoofdprint Profibus PA
-
Nr 40 Order code 51502503
CPM2X3 Centraalmodu Profibus DP
-
Nr 40 Order code 71134724
Kit CPM2x3: Central mod. PB DP; H/W 2.1x
Inhoud: 1x Centrale module Profibus DP Module naam: LSCP-DP qualifired van H/W 2,10
-
-
-
Nr 290 Order code 71134732
Kit CxM2x3: Relay mod. for PBDP; H/W2.1x
Inhoud: 1x Relaismodule Profibus DP 2x relais, 1x Stroomingang DP- aansluiting gekwalificeerd vanaf H/W 2,10
-
-
-
Nr 422 Order code 51501205
CUM223 Klemmenset (niet voor PA/DP!)
-
Nr 422 Order code 51501077
CPM223 aansluitklemmen voeding en alarm
-
Nr 422 Order code 51502125
CPM223 klemmenstrook Profibus PA
-
Nr 422 Order code 51502494
CPM223 Klemmenset Profibus DP
-
-
-
Nr 235 Order code 51501070
CPM223 BNC ingangsplug met afscherming
-
-
-
Nr 335 Order code 71071440
Kit CxM223: front foil + 6 key lifters
-
-
-
Order code 51500385
CxM2x3 PLUSPAKKET KIT
Upgrade of LIQUISYS-M basic version (parameter pH,Cond.,Tu,CL,O2 (WX to WS)) to S-version (plus-package). Serial number of instrument needed.
-
Order code 51500963
UPGRADE CLEANING VOOR LIQUISYS-M
Upgrade of LIQUISYS-M basic version by cleaning functionality (Chemoclean) (serial number of instrument needed). If not yet installed, a 4-relay board must be ordered separately (51500321).
-
-
-
Nr 210 Order code 50074961
Steker BNC haaks
Angular plug for connection of a pH measuring cable (for panel- mounted transmitter).
-
-
-
Order code 50047795
CXM 121 bevestigingsklem.
-
-