Voer tenminste 2 karakters in om het zoeken te starten.
  • Geschiedenis

iTHERM TM412
Imperial Hygienic Thermometer,
US style

Hygienic thermometer iTHERM TM412 - Imperial version US Style ©Endress+Hauser

For use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries

It has been designed to meet the requirements of the Food & Beverages and Life Sciences industries and complies with the highest quality standards. It offers a variety of versions within a clearly segmented standard product. The result: Time and cost savings by simple and fast product selection. It offers many technical innovations: iTHERM QuickSens, StrongSens or QuickNeck. This leads to distinctive reduction of maintenance costs, improved product quality, process efficiency and safety.

Snelle selectie

Kies uit één van de voorgestelde opties
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

of

Individuele configuratie

Ga verder met uw keuze uit alle mogelijke opties
  • Voordelen

    • User-friendly and reliable from product selection to maintenance

    • iTHERM inserts: globally unique, fully-automated production. Full traceability and consistently high product quality for reliable measured values

    • iTHERM QuickSens: fastest response times...

  • Toepassingsgebied

    • Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries

    • Measuring range: –200 to +600 °C (–28 to +1 112 °F)

    • Pressure range up to 40 bar (580 psi)

    • Protection class: up to IP69K

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Resistance Temperature Detector

  • Characteristic / Application

    imperial style

    modular temperature assembly

    hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA)

    hygienic process connections

    with neck

    suitable for hazardous areas

    incl. protection tube

    QuickSens for fastest response time

    StrongSens for most robust design

    QuickNeck for easy and cost saving recalibration

  • Thermowell / protection tube

    without

    incl. thermowell

    incl. T-/ellbow thermowell

  • Insert / probe

    mineral insulated (MI), flexible

    pipe version, isolated wires, not flexible

  • Outer diameter protection tube / Insert

    1/4'' (6,35 mm)

    3/8'' (9,53 mm)

    1/2" (12,7 mm)

  • Max. immersion length on request

    48"

  • Material protection tube/ thermowell

    316L

  • Process connection

    Weld-in adapter

    Tri-clamp

    Clamp-connections according to ISO2852

    G3/4" Liquiphant

    G1" Liquiphant

    Varivent

    T- and corner pieces

  • Tip shape

    straight

    reduced

  • Surface roughness Ra

    30 μin (0,76 μm)

    15 μin (0,38 μm )

    15 μin (0,38 μm) electropolished

  • Operating temperature range

    PT100 WW:

    -200 °C … 600 °C

    (-328 °F … 1.112 °F)

    StrongSens:

    -50 °C … 500 °C

    (-58 °F … 932 °F)

    QuickSens:

    -50 °C … 200 °C

    (-58 °F … 392 °F)

    PT100 TF:

    -50 °C … 200 °C

  • Max. process pressure (static)

    at 20 °C: 40 bar (580 psi)

  • Accuracy

    class B acc. to IEC 60751

    class A acc. to IEC 60751

    class AA acc. to IEC 60751

  • Response time

    depending on configuration

    QuickSens: t90 = 1,5 s

    StrongSens: t90 = 9,5 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    ATEX II

    ATEX IECEx

    FM

    CSA

  • Certification

    SIL (transmitter only)

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
    • Order code 52018765

      Inlasadapter G3/4" voor vlakke inbouw

      Inbouw proces-verbinding Materiaal: 316L. Inspectie cert. EN10204-3.1 materiaal. Afdichting: siliconen O-ring. FDA, EHEDG, 3-A compliant. Gebruik: FMI51, FTI51, FTL20/FTL20H, FTL31/FTL33, FTW23/FTW33, QMW43, 11371. Gebruik: TMR35. Dit betreft een product uit het E-direct portfolio met een scherpe netto prijs. Kijk voor meer informatie op www.e-direct.endress.com

    • Order code 52021717

      O-ring 14.9x2.7 VMQ, FDA, 5 pcs.

      Materiaal: silicone VMQ 75. Gebruik. Lasadapter G3/4,316L, lasadapter: Lasadapter G3/4, 316L, (71258355) scheepsmontage, (71258357) pijpmontage, verzonken montage, FTL31/FTL33, FTW23/FTW33, QMW43, Lasadapter G3/4, 316L, 3.1, (52018765) scheepsmontage, (52028295) pijpmontage, inbouwmontage, FMI51, FTI51, FTL31/FTL33, FTW23/FTW33, QMW43.

    • Order code 52028295

      inlasadaptor G3/4, d=29, 316L, 3.1

      Inbouw proces-verbinding. Buisleiding monteren. Materiaal: 316L. Inspectie cert. EN10204-3.1 materiaal. Seal: siliconen O-ring. FDA, EHEDG compliant. Gebruik: FTL20/FTL20H, FTL31/FTL33, FTW23/FTW33, QMW43.

    • Order code 52001052

      Inlasadapter G3/4, d=55, 316L

      Inbouw proces-verbinding. Materiaal: 316L. Seal: siliconen O-ring. FDA, EHEDG, 3A compliant. Gebruik: FTL50/FTL50H, FTL80, QMW43. Gebruik: TMR35.

    • Order code 52011897

      Weld-in adapter G3/4, 316L, 3.1

      Inbouw proces-verbinding. Materiaal: 316L. Inspectie cert. EN10204-3.1 materiaal. Seal: siliconen O-ring. FDA, EHEDG, 3A compliant. Gebruik: FTL50/FTL50H, FTL80, QMW43. Gebruik: TMR35.

    • Order code 52014473

      O-ring 21,89x2,62 VMQ 70, FDA, 5 pcs.

      Materiaal: silicone VMQ 70. Gebruik: lasadapter G3/4, 316L (52001052) inbouwmontage, 316L, 3.1 (52011897) inbouwmontage, FTL50/FTL50H/FTL51/FTL51H, FTL80/FTL81

    • Order code 52001051

      Inlasadapter G1, d=60, 316L

      Inbouw proces-verbinding. Materiaal: 316L. Seal: siliconen O-ring. FDA, EHEDG, 3-A compliant. Gebruik: FMI51/FMI52, FTI51/FTI52, FTL20/FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL80/FTL81, FTL260, FTW23, FTW33, PMP23, PMP51, PMP135, PTP33B/PTP35, QMW43. Usage: TM401/TM411, TMR35. Dit betreft een product uit het E-direct portfolio met een scherpe netto prijs. Kijk voor meer informatie op www.e-direct.endress.com

    • Order code 52011896

      Inlasadapter G1, d=60, 316L, 3.1

      Inbouw proces-verbinding. Materiaal: 316L. Inspectie cert. EN10204-3.1 materiaal. Seal: siliconen O-ring. FDA, EHEDG, 3-A compliant. Gebruik: FMI51/FMI52, FTI51/FTI52, FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL80/FTL81, FTL260, FTW23, FTW33, PMP23, PMP51, PMP135, PTP33B/PTP35, QMW43. Gebruik: TM401/TM411, TMR35. Dit betreft een product uit het E-direct portfolio met een scherpe netto prijs. Kijk voor meer informatie op www.e-direct.endress.com

    • Order code 71093129

      Inlas adaptor G 1", d=53, 316L, 3.1

      Inbouw proces-verbinding. Materiaal: 316L. Inspectie cert. EN10204-3.1 materiaal Afdichting: silicone O-ring FDA, EHEDG, 3-A compliant. Gebruik: FMI51/FMI52, FTI51/FTI52, FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL80/FTL81, FTL260, FTL330H/FTL330L, FTW23, FTW33, PMP135, PTP35, QMW43.

    • Order code 52014472

      O-Ring28,17x3,53Silicon,5st

      Materiaal: silicone VMQ 70. Gebruik: lasadapter G1, 316L, (52001051) inbouwmontage, FMI51/FMI52, FTI51/FTI52, FTL31/FTL33, FTW23/FTW33, PMP23, PMP51, PTP33B, FTL50/FTL50H/FTL51/FTL51/FTL51H, FTL80/FTL81, QMW43, Lasadapter G1, 316L, 3.1, (52011896) inbouwmontage, FMI51/FMI52, FTI51/FTI52, FTL31/FTL33, FTW23/FTW33, PMP23, PMP51, PTP33B, FTL50/FTL50H/FTL51/FTL51/FTL51H, FTL80/FTL81,QMW43, schuifbus FTM21.

    • Order code 52001221

      Hygienische inlasadapter G1", draaibaar

      Inbouw proces-verbinding. Materiaal: 316L. Liquiphant is instelbaar. Seal: siliconen profiel pakking. FDA, EHEDG, 3-A compliant. Gebruik: FTL20/FTL20H,FTL330H/330L,FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL80/81.

    • Order code 52011898

      Weld-in adapter G1, adjustable,316L, 3.1

      Inbouw proces-verbinding. Materiaal: 316L. Liquiphant instelbaar. Inspectie cert. EN10204-3.1 materiaal. Afdichting: siliconen profiel pakking. FDA, EHEDG, 3-A compliant. Usage: FTL20_020_7, FTL20H_020_GEJ, FTL330H / 330L_020_G, FTL31_110_WSJ, FTL33_110_WSJ, FTL5x / 5xH_020_GW2, FTL80 / 81_100_WSJ.FTL80 /81_100_WSJ.

    • Order code 52014424

      Profile gasket 29x36x3.7, FDA, 5 pcs.

      Materiaal: silicone VMQ. Gebruik: Het proces verbindt. G1 inbouwmontage, Lasadapter G1, 316L, instelbaar (52001221), Lasadapter G1, 316L, 3.1, instelbaar (52011898), FTL31/FTL33, FTL80/FTL81, FTL50/FTL50H/FTL51/FTL51/FTL51H, Lasadapter Rd52, 316L, verstelbaar, (52001047), 316L, 3.1, verstelbaar, (52006909), FTL33, FTL50/FTL50H/FTL51/FTL51H, QMW43.

    • Order code 71275424

      grip cap flexible yellow TPE

    • Order code 51516983

      Commubox FXA291 (USB) - Service/CDI

      Seriële USB Computer Interface Technische data: - USB Version1.1 of hoger - Voeding via USB - IP51; NEMA/Typ 3 - Omgevingstemperatuur: -20....+60°C - Ex: II (2) G (EEx ia) II C - ATEX: BVS 05 ATEX E 095 Leveringsomvang: Commubox FXA291 MS Windows USB-stuurprogramma Het apparaat is ingediend voor CSA/FM toepassing. Het apparaat mag niet worden gewijzigd en kan gebruikt worden met intrinsiek veilige circuits. Alleen met overeenkomstige eigenschappen (zie veiligheidscertificaat).

    • Order code TS212-

      Insert imperial iTHERM TS212

      Insert replaceable central spring load imperial version ::Fastest response times for optimal process control through iTHERM QuickSens insert. ::Maximum robustness for highest process safety through iTHERM StrongSens insert. Maximum RTD accuracy at high temperature through iTHERM HotSens insert.

    • Order code TT412-

      iTHERM TT412 Thermowell

      Thermowell with hygienic design. Imperial version for applications in the food/beverages and pharmaceutical industries.

    • Order code TMT162-

      iTEMP TMT162, Field Transmitter

      Temperature transmitter. Application: RTD, TC, Ohm, mV. HART, PROFIBUS PA Profile 3.02 or FOUNDATION Fieldbus separately available. Galvanic isolation 2 kV (sensor input/output). NEMA Type 4X Encl., IP67. Dual compartment. DNV GL marine approval (only HART). UL listed.

    • Order code TMT180-

      iTEMP TMT180, Head Transmitter Pt100

      Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Order code TMT181-

      iTEMP TMT181, Head Transmitter PCP

      Product being phased out, limited availability. Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Order code TMT84-

      iTEMP TMT84, Transmitter PA

      Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Order code TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Order code TID10-

      Display for head transmitter TID10

      to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84, TMT82.

    • Order code XPT0004-

      Spare parts kit cover terminal headTA30R

      cover of connecting head

    • Order code TA30A-

      Terminal Head TA30A

      Retainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).

    • Order code TA30D-

      Terminal Head TA30D

      Retainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).

    • Order code TA30P-

      Terminal Head TA30P

      Retainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: Polyamid PA12 antistatic. Colour: black. Ambient temp.: -40...120oC (housing). Protection: IP65 (housing).

    • Order code TA30R-

      Terminal Head TA30R

      Retainer for terminal block or head transmitter + optional display. Cover: screwed, optional window. Material: Stainless Steel 316L. Colour: Steel (no coating). Ambient Temp.: -50...85/130 oC (display/standard). Protection: IP66/68, NEMA4X; IP69K (housing). :: easy wiring through best accessibility. :: compact desing and low weight.

    • Order code TA30S-

      Terminal Head TA30S

      Retainer for terminal block or head transmitter. Cover: screwed. Material: Polypropylene. Colour: white. Ambient Temperature: -30...+130oC. Protection: IP65, NEMA4X (housing). :: easy wiring through good accessibility. :: compact design, low weight.

    • Order code TMT182-

      iTEMP TMT182, Head Transmitter HART

      Product being phased out, limited availability. Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.

    • Order code FXA195-

      Commubox FXA195

      Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.

    • Order code TXU10-

      Configuration kit TXU10-

      for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.

    • Order code SFE500-

      FieldCare

      FieldCare is a Software tool based on FDT/DTM technology. FieldCare is scalable which allows to fulfill tasks from Device Setup to Plant Asset Management. FieldCare includes tested and approved Endress+Hauser and third party DTMs and may be combined with other Endress+Hauser products like Condition Monitoring or W@M. Additional hardware (e.g. modems, cable) is needed. A software support service including updates to guarantee top quality and perfomance is recommended.

    • Order code FXA42-

      Fieldgate FXA42

      Compact gateway for data capture of field devices, without antenna. Embedded web server, alarm / event handling. Application: remote monitoring, inventroy data monitoring, web enabled field interface. Field device interfaces 4-20mA, Modbus RTU, digital inputs/outputs. :: Meets NAMUR NE43 requirements. :: Data transition into SupplyCare.

    • Order code TM412-

      iTHERM TM412

      Modular,hygienic resistance thermometer. Imperial version with exchangeable insert for applications in the food/ beverages and pharmaceutical industries. With thermowell. Measuring range: -328...+1.112oF/ -200...+600oC (depending on the configuration). :::Fastest response times for optimal process control through iTHERM QuickSens insert. ::Maximum robustness for highest process safety through iTHERM StrongSens insert. ::Cost savings with recalibrations through iTHERM QuickNeck coupling.