Proline Cubemass C 500
Coriolis flowmeter

Coriolis flowmeter - Proline Cubemass C 500 ©Endress+Hauser

The Coriolis Flow Measuring Principle

Ultra-compact sensor for smallest quantities, with a transmitter remote version with up to 4 I/Os

Cubemass C is the ultra-compact specialist for smallest flow rates. Even under high pressure, it doesn't compromise measurement accuracy. With its innovative remote transmitter Cubemass C 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology ensures compliance and process safety at all times.

  • Voordelen

    • Reduced installation cost – compact single-tube design

    • Fewer process measuring points – multivariable measurement (flow, density, temperature)

    • Space-saving installation – no in/outlet run needs

    • Full access to process and diagnostic information – numerous,...

  • Toepassingsgebied

    • Measuring principle operates independently of physical fluid properties such as viscosity or density

    • Measuring accurately smallest quantities of liquids and gases.

    Device properties

    • Nominal diameter: DN 1 to 6 (1/24 to 1/4")

    • Process pressure up to 400...

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Coriolis

  • Product headline

    Compact sensor for smallest quantities, with a transmitter remote version with up to 4 I/Os. Measuring accurately smallest quantities of liquids and gases.

  • Sensor features

    Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi).

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access.

  • Nominal diameter range

    DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")

  • Wetted materials

    Measuring tube: 1.4539 (904L)
    Connection: 1.4539 (904L); 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.10 %
    Volume flow (liquid): ±0.10 %
    Mass flow (gas): ±0.50 %
    Density (liquid): ±0.0005 g/cm3

  • Measuring range

    0 to 1000 kg/h (0 to 37 lb/min)

  • Max. process pressure

    PN 40, Class 300, 10K, 400 bar (5800 psi)

  • Medium temperature range

    –50 to +205 °C (–58 to +401 °F)

  • Ambient temperature range

    Standard: –40 to +60 °C (–40 to +140 °F)
    Option: –50 to +60 °C (–58 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

    Sensor connection housing (standard): AlSi10Mg, coated

    Sensor connection housing (option): 1.4301 (304); 1.4404 (316L)

  • Transmitter housing material

    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat

  • Degree of protection

    Sensor remote version (standard): IP66/67, type 4X enclosure
    Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 outputs:
    4-20 mA HART (active/passive)
    4-20 mA WirelessHART
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Double pulse output (active/passive)
    Relay output

  • Inputs

    Status input
    4-20 mA input

  • Digital communication

    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV attestation)

  • Pressure approvals and certificates

    CRN

  • Material certificates

    3.1 material

  • Meetprincipe

    Coriolis

  • Product headline

    Compact sensor for smallest quantities, with a transmitter remote version with up to 4 I/Os. Measuring accurately smallest quantities of liquids and gases.

  • Sensor features

    Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi).

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access.

  • Nominal diameter range

    DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")

  • Wetted materials

    Measuring tube: 1.4539 (904L)
    Connection: 1.4539 (904L); 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.10 %
    Volume flow (liquid): ±0.10 %
    Mass flow (gas): ±0.50 %
    Density (liquid): ±0.0005 g/cm3

  • Measuring range

    0 to 1000 kg/h (0 to 37 lb/min)

  • Max. process pressure

    PN 40, Class 300, 10K, 400 bar (5800 psi)

  • Medium temperature range

    –50 to +205 °C (–58 to +401 °F)

  • Ambient temperature range

    Standard: –40 to +60 °C (–40 to +140 °F)
    Option: –50 to +60 °C (–58 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

    Sensor connection housing (standard): AlSi10Mg, coated

    Sensor connection housing (option): 1.4301 (304); 1.4404 (316L)

  • Transmitter housing material

    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat

  • Degree of protection

    Sensor remote version (standard): IP66/67, type 4X enclosure
    Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 outputs:
    4-20 mA HART (active/passive)
    4-20 mA WirelessHART
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Double pulse output (active/passive)
    Relay output

  • Inputs

    Status input
    4-20 mA input

  • Digital communication

    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV attestation)

  • Pressure approvals and certificates

    CRN

  • Material certificates

    3.1 material

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
  • 31
    • Nr 31 Order code 71323007

      Kit power supply, 100-230VAC, Ex

      Gebruik: Promag/Promass 300/500, transmitterbehuizing, elektronisch compartiment.

    • Nr 31 Order code 71323008

      Kit power supply, 24VDC, Ex

      Gebruik: Promag/Promass 300/500, transmitterbehuizing, elektronisch compartiment.

    • Nr 31 Order code 71323009

      Kit pow.supply,100-230VAC/24VDC, Non-haz

      Gebruik: Promag/Promass 300/500 digitaal. Niet gevaarlijk, Zone 2, transmitterbehuizing, elektronisch compartiment.

  • 47
    • Nr 47 Order code 71323012

      Kit main elec.extend.,Promass500 dig.,Ex

      Gebruik: transmitterbehuizing, elektronisch compartiment.

    • Nr 47 Order code 71323013

      Kit main elec.extender,500 dig., Non-haz

      Gebruik: Transmitterbehuizing, elektronisch compartiment.

  • 36
  • 39
    • Nr 39 Order code 71185788

      Kit T-DAT, Promass 100

      Gebruik: Promag / Promass 100/300/500, 500 digitaal, Prosonic Flow E 100, Promag 400 (C). (C) = opwekkingsindex C.

  • 33
  • 37
    • Nr 37 Order code 71323010

      Kit module cartridge, 300/500, Ex

      Gebruik: Transmitterbehuizing, elektronisch compartiment. Bestaat uit: module cartridge incl. interconnectie board.

  • 34
  • 46
  • 45
    • Nr 45 Order code 71323075

      Kit conn.terminal option A, 300/500, Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie A= HART, Profibus PA, FOUNDATION Fieldbus. Bestaat uit: 2x aansluiting 2-Pol., 1x aansluiting 4-Pol.

  • 35
  • 45
    • Nr 45 Order code 71323076

      Kit conn.terminal option B, 300/500, Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie B= Ethernet, PROFINET. Bestaat uit: 2 x aansluiting 2-Pol.

  • 50
  • 45
    • Nr 45 Order code 71327819

      Kit conn.terminal option C, 300/500, Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie C= PROFIBUS-DP, Modbus RS485. Bestaat uit: 2x aansluiting 2-Pol., 1x aansluiting 4-Pol.

    • Nr 45 Order code 71323077

      Kit terminal option A, 500 dig., Non-haz

      Gebruik: transmitterbehuizing Alu/polycarbonaat, aansluitruimte. Optie A= HART, Profibus PA, FOUNDATION Fieldbus. Bestaat uit: 1x aansluiting 2-Pol., 1x aansluiting 3-Pol., 1x aansluiting 4-Pol., 1x aansluitklem 6-Pol.

    • Nr 45 Order code 71323078

      Kit terminal option B, 500 dig., Non-haz

      Gebruik: transmitterbehuizing Alu/polycarbonaat, aansluitruimte. Optie B= Ethernet, PROFINET. Bestaat uit: 1x aansluiting 3-Pol., 1x aansluiting 4-Pol., 1x aansluitklem 6-Pol.

    • Nr 45 Order code 71327820

      Kit terminal option C, 500 dig., Non-haz

      Gebruik: transmitterbehuizing Alu/polycarbonaat, aansluitruimte. Optie C = PROFIBUS-DP, Modbus RS485. Bestaat uit: 1x aansluiting 2-Pol., 1x aansluiting 3-Pol., 1x aansluiting 4-Pol., 1x aansluitklem 6-Pol.

  • 44
    • Nr 44 Order code 71323268

      Kit connection board, Promass 500, Ex

      Gebruik: Sensoraansluiting behuizing. Bestaat uit: aansluiting board, O-Ring 26,00x1,50 HNBR.

    • Nr 44 Order code 71323269

      Kit connec.board, Promass 500, Ex, -50oC

      Gebruik: Sensoraansluiting behuizing. Bestaat uit: aansluiting board, O-Ring 26,00x1,50 FVMQ, -50°C/-58°F.

  • 20
    • Nr 20 Order code 71323016

      Kit cover, sight glass, Alu,Non-haz/Exde

      Gebruik: Promag/Promass 300, transmitterbehuizing Alu, Niet gevaarlijk. Promag/Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, kijkglas, O-Ring 110.7x3.53 HNBR.

    • Nr 20 Order code 71323017

      Kit cover,glass, Alu, -50oC,Non-haz/Exde

      Gebruik: Promass 300, transmitterbehuizing Alu, niet- gevaarlijk. Promag 500, Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, kijkglas, O-ring 110,7 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 20 Order code 71323020

      Kit cover, sight glass, Alu, Exd

      Gebruik: Promag /Promass 300/500, Transmitter behuizing Alu, Ex. Bestaat uit: Cover Alu, zichtglas, O-Ring 110,7x3,53 HNBR.

    • Nr 20 Order code 71323021

      Kit cover, sight glass, Alu, -50oC, Exd

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, kijkglas, O-ring 110,7 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 20 Order code 71323024

      Kit cover, sight glass, cast, Ex

      Gebruik: Promag/Promass 300/500, transmitterbehuizing cast, Ex. Bestaat uit: deksel gegoten, kijkglas, O-Ring 110.7x3.53 HNBR.

    • Nr 20 Order code 71323025

      Kit cover, sight glass, cast, -50oC, Ex

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing cast, Ex. Bestaat uit: deksel gegoten, kijkglas, O-ring 110,7 x 3,53 FVMQ, -50°C/-58°F.

  • 70
    • Nr 70 Order code 71323026

      Kit cover gasket, sight glass/blind

      Gebruik: Promag/Promass 300/500, transmitterbehuizing Alu/cast. Bestaat uit: 10x O-Ring 110.7x3.53 HNBR.

    • Nr 70 Order code 71323027

      Kit cover gasket,sight glass/blind,-50oC

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing Alu/cast, Bestaat uit: O-ring 110,7 x 3,53 FVMQ, -50°C/-58°F.

  • 22
    • Nr 22 Order code 71323032

      Kit cover, electronic compart., Alu, Ex

      Gebruik: Promag/Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, O-ring 120,2 x 3,53 HNBR.

    • Nr 22 Order code 71323033

      Kit cover, electr.compart., Alu,-50oC,Ex

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, O-ring 120,2 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 22 Order code 71323034

      Kit cover, electronic compart., cast, Ex

      Gebruik: Promag/Promass 300/500, transmitterbehuizing cast, Ex. Bestaat uit: deksel gegoten, O-ring 120,2 x 3,53 HNBR.

    • Nr 22 Order code 71323035

      Kit cover, electr.compart.,cast,-50oC,Ex

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing cast, Ex. Bestaat uit: deksel gegoten, O-ring 120,2 x 3,53 FVMQ, -50°C/-58°F.

  • 74
    • Nr 74 Order code 71323036

      Kit cover gasket, electronic compart.,Ex

      Gebruik: Promag/Promass 300/500, transmitterbehuizing Alu/cast, Ex. Bestaat uit: 10x O-ring 120,2 x 3,53 HNBR.

    • Nr 74 Order code 71323037

      Kit cover gasket,elect.compart.,-50oC,Ex

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing Alu/cast, Ex. Bestaat uit: O-ring 120,2 x 3,53 FVMQ, -50°C/-58°F.

  • 23
    • Nr 23 Order code 71323038

      Kit cover, wall mount, Alu, Ex

      Gebruik: Promag/Promass 500, wall mount transmitter Alu, Ex, aansluitruimte. Bestaat uit: afdekking Alu, O-ring 88,50 x 3,53 HNBR.

    • Nr 23 Order code 71323039

      Kit cover, wall mount, Alu, -50oC, Ex

      Gebruik: Promag/Promass 500, wall mount zender Alu, Ex, aansluitruimte. Bestaat uit: afdekking Alu, O-ring 88,50 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 23 Order code 71323040

      Kit cover, wall mount, cast, Ex

      Gebruik: Promag/Promass 500, wall mount zender cast, Ex, aansluitruimte. Bestaat uit: deksel gegoten, O-ring 88,50 x 3,53 HNBR.

    • Nr 23 Order code 71323041

      Kit cover, wall mount, cast, -50oC, Ex

      Gebruik: Promag/Promass 500, wall mount zender cast, Ex, aansluitruimte. Bestaat uit: deksel gegoten, O-ring 88,50 x 3,53 FVMQ, -50°C/-58°F.

  • 75
    • Nr 75 Order code 71323042

      Kit cover gasket, wall mount, Ex

      Gebruik: Promag/Promass 500, wall mount transmitter Alu/cast, Ex, aansluitruimte. Bestaat uit: 10x O-ring 88,50 x 3,53 HNBR.

    • Nr 75 Order code 71323043

      Kit cover gasket, wall mount, -50oC, Ex

      Gebruik: Promag/Promass 500, wall mount transmitter Alu/cast, Ex, aansluitruimte. Bestaat uit: O-ring 88,50 x 3,53 FVMQ, -50°C/-58°F.

  • 20
    • Nr 20 Order code 71384170

      Kit cover, alu,Promag 400(C),500 digital

      Gebruik: Promag 400(C)= generatie-index C, Promag / Promass 500 digitaal, zenderbehuizing Alu. Bestaat uit: dekking Alu compleet inbegrepen O-ring 196,44x3,53 VMQ, standaard en -50°C/-58°F, draad met schroefslot 1,5x150

    • Nr 20 Order code 71408508

      Kit cover, polycarb., 500 digital

      Gebruik: Promag/Promass 500 digitaal, polycarbonaat behuizing van de zender. Bestaat uit: Bedek polycarbonaat compleet, O-ring 196,44x3,53 VMQ, standaard en -50°C/-58°F, draad met schroefslot 1,5x150.

  • 70
    • Nr 70 Order code 71278078

      Kit 10 cover gasket, alu, 400(C)

      Gebruik: Promag 400(C)= generatie index C, Promag/Promass 500 digitale, transmitterbehuizing Alu, Ex. Bestaat uit: 10x O-Ring 196,44x3,53 VMQ, verzuim en -50°C/-58°F.

    • Nr 70 Order code 71278077

      Kit 10 afdichtingsring, polycarbonaat

      Gebruik: Promag 400(C), 500 digitaal met polycarbonaat behuizing. (C)= generatie-index C. Bestaat uit: 10x O-Ring 196,44x3,53 VMQ.

  • 24
    • Nr 24 Order code 71228796

      Kit cover, remote, Alu

      Gebruik: Promag 400(C)= generatie index C, Promag 500, Promass/Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: afdekking Alu, O-Ring 113,90x3,53 HNBR.

    • Nr 24 Order code 71323050

      Kit cover, remote, Alu, -50oC

      Gebruik: Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: afdekking Alu, O-Ring 113,90x3,53 FVMQ, -50°C/-58°F.

  • 73
    • Nr 73 Order code 71323051

      Kit housing gaskets, remote, Alu

      Gebruik: Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: O-Ring 113,90x3,53 HNBR voor dekking, pakking EPDM voor huisvesting/sensor.

    • Nr 73 Order code 71323052

      Kit housing gaskets, remote, Alu, -50°C

      Gebruik: Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: O-Ring 113,90x3,53 FVMQ voor dekking, -50°C/-58°F, pakking FVMQ voor huisvesting/sensor, -50°C/-58°F.

  • 24
    • Nr 24 Order code 71323053

      Kit cover, remote, stainless 1.4301

      Gebruik: Promass 500, Promass/Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: bestrijken roestvrij 1.4301, pakking EPDM voor dekking.

    • Nr 24 Order code 71323054

      Kit cover, remote,stainless 1.4301,-50oC

      Gebruik: Promass 500, Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: bestrijken roestvrij 1.4301, pakking FVMQ voor dekking, -50°C/-58°F.

  • 73
    • Nr 73 Order code 71323057

      Kit housing gaskets, remote, stainless

      Gebruik: Promass 500, Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: pakking EPDM voor dekking, pakking EPDM voor huisvesting/sensor.

    • Nr 73 Order code 71323058

      Kit hous.gaskets, remote,stainless,-50oC

      Gebruik: Promass 500, Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: pakking FVMQ voor dekking,-50°C/-58°F, pakking FVMQ voor huisvesting/sensor, -50°C/-58°F.

  • 24
    • Nr 24 Order code 71185793

      Kit cover,ultra compact,stainless 1.4301

      Gebruik: Promag/Promass 100, Promag/Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: bestrijken roestvrij 1.4301, pakking EPDM voor dekking.

    • Nr 24 Order code 71323060

      Kit cover, ultra compact, 1.4301, -50oC

      Gebruik: Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: bestrijken roestvrij 1.4301, pakking FVMQ voor dekking, -50°C/-58°F.

  • 73
    • Nr 73 Order code 71185799

      Kit hous. gasket,ultra compact,stainless

      Gebruik: Promass 100, Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: pakking EPDM voor dekking, pakking EPDM voor huisvesting/sensor.

    • Nr 73 Order code 71323062

      Kit housing gasket, ultra compact, -50oC

      Gebruik: Promass 500 digitale, sensor aansluiting roestvrijstalen behuizing. Bestaat uit: Pakking FVMQ voor dekking, -50°C/-58°F, pakking FVMQ voor huisvesting/sensor, -50°C/-58°F.

  • 24
    • Nr 24 Order code 71323063

      Kit cover, remote, cast, Ex

      Gebruik: Promag/Promass 500, Promass/Promass 500 digitale, sensor connector behuizing. Bestaat uit: deksel gegoten, O-Ring 120,2x3,53 HNBR.

    • Nr 24 Order code 71323064

      Kit cover, remote, cast, -50oC, Ex

      Gebruik: Promass 500, Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: deksel gegoten, O-ring 120,2 x 3,53 FVMQ,-50°C/-58°F

  • 73
    • Nr 73 Order code 71323065

      Kit housing gaskets, remote, cast, Ex

      Gebruik: Promass 500, Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: O-Ring 120,2x3,53 HNBR voor dekking, O-ring 88,50 x 3,53 HNBR voor huisvesting/sensor

    • Nr 73 Order code 71323066

      Kit housing gaskets,remote,cast,-50oC,Ex

      Gebruik: Promass 500, Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: O-Ring 120,2x3,53 FVMQ voor dekking, -50°C/-58 VAn, O-Ring 88,50x3,53 FVMQ voor house./sensor, -50°C/-58°F.

  • 71
    • Nr 71 Order code 71323071

      Kit interface gaskets, Promass 300/500

      Gebruik: transmitter behuizing/sensor of transmitter behuizing/muurbevestiging. Bestaat uit: 5x O-ring 88,50 x 3,53 HNBR voor interface.

    • Nr 71 Order code 71323072

      Kit interf.gaskets,Promass 300/500,-50°C

      Gebruik: transmitter behuizing/sensor of transmitter behuizing/muurbevestiging. Bestaat uit: O-ring 88,50 x 3,53 FVMQ voor -interface, -50°C /-58°F.

  • 11
    • Nr 11 Order code 71323081

      Kit protective cover option A,300/500,Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie A= HART, Profibus PA, Profibus DP, Modbus RS485, FOUNDATION Fieldbus. Bestaat uit: Aansluitruimte beschermhoes, vertoning vervoerder, 2x schroef M4x10.

    • Nr 11 Order code 71323082

      Kit protective cover option B,300/500,Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie B= Ethernet, PROFINET. Bestaat uit: Aansluitruimte beschermhoes, vertoning vervoerder, 2x schroef M4x10.

  • 13
    • Nr 13 Order code 71276494

      Kit securing clamp, screw

      Gebruik: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Sensorhuis: Promag 400 (C), (C)= opwekkingsindex C, Promag / Promass 500, Promag / Promass 500 digitaal. Bestaat uit: afdekklem, schroef M4x16.

  • 82
    • Nr 82 Order code 71228792

      Kit display protection, Promag 400(C)

      Gebruik: Promag 400(C) = generatie index C, Promag/Promass 500 digitale, transmitterbehuizing. Bestaat uit: beeldscherm bescherming 1.4301, installatiemateriaal.

  • 87
    • Nr 87 Order code 71343504

      Kit weather protection cover,500 digital

      Gebruik: Promag/Promass 500 digital, transmitterbehuizing. Bestaat uit: weer beschermingskap 4404.

    • Nr 87 Order code 71343505

      Kit weather protection cover, 300/500

      Gebruik: Promag/Promass 300/500, transmitterbehuizing. Bestaat uit: weer bescherminskap 4404, installatiemateriaal.

    • Order code 71346427

      Pipe Mounting kit Transmitter 500digital

    • Order code 71346428

      Pipe Mounting kit Transmitter 500

    • Order code 71123816

      Mounting plate Cubemass packed

      Universal mounting plate for fixing the flowmeter to various surfaces, such as walls, switchboards etc.

    • Order code 71351317

      Kit wireless antenna extended range

      Bestaat uit: Verbindingskabel in de transmitter, Ex kabelinvoer voor antenne, 1,5 m kabel,antenne,hoek met wartelmoer.

    • Order code 8X5BXX-

      Transmitter Promass 500, 8X5BXX

      Met een geïntegreerde webserver.

    • Order code DK8012-

      Promass 500, sensor kabel set

      Aansluitkabel (Analoog en digtaal) tuseen sensor junction box en remote transmitter voor Proline 500 serie

    • Order code DKS-

      Promass afichtingset

      Een set bestaat uit 2 afdichtingen

    • Order code DK8CS-

      Cubemass, montageset

      Adapters voor verschillende standaards, voor proces aansluitingen. Te monteren op de Cajon koppelingen.

    • Order code XPRFID-

      Spare RFID TAG

      Bestaat uit: RFID-tag, het bevestigen draad, krimp mouw.