Zoek op trefwoord, order- of productcode of serienummer, bv. “CM442” of “Technische informatie”
Voer tenminste 2 karakters in om het zoeken te starten.
  • Geschiedenis
Memosens CPS96E - Digitale, gecombineerde pH/ORP-sensor voor chemische processen, papier- of verfproductie

Digitale gecombineerde pH/Redox-sensor Memosens CPS96E

Memosens 2.0 elektrode voor zwaar vervuilde media in chemische processen, papier- of verfproductie

CPS96E
Please Wait (spinning wheel)
Prijzen worden geladen
Prijzen tijdelijk niet beschikbaar
Price on request
Bezig met activeren van prijs
Prijs: Informatie verstrekken
from CHF ??.-
Filter meting-/ toepassingstaak
Meet-/toepassingstaak

Configureer om de CAD-tekeningen van dit product te downloaden

  • Meetprincipe

    Potentiometric

  • Application

    pH / ORP sensor for heavily contaminated media
    and suspended solids
    • Chemical processes
    • Pulp and paper industry
    • Flue gas cleaning
    • Contaminated media:
    • Solids
    • Emulsions
    • Precipitation reactions

  • Characteristic

    Gel pH/ORP electrode with open aperture and double gel reference with ion trap for chemical applications

  • Measurement range

    ORP: –1 500 to 1 500 mV
    pH: 0 to 14

  • Measuring principle

    Pt-disc as additional ORP element
    rH measurement and control of the reference impedance

  • Design

    All shaft lengths with temperature sensor
    Advanced gel technology
    Hydrolysis stable gel

  • Material

    Sensor shaft: Glass to suit process
    pH membrane glass: Type B
    Metal lead: Ag/AgCl
    ORP measuring element: Platinum
    O-ring: FKM
    Process coupling: PPS fiber-glass reinforced
    Nameplate: Ceramic metal oxide

  • Dimension

    Diameter: 12 mm (0.46 inch)
    Shaft lengths: 120, 225, 360 and 425 mm
    (4.68, 8.77, 14.04 and 16.57 inch)

  • Process temperature

    0 to 110 °C (32 to 230 °F)

  • Process pressure

    0.8 to 14 bar (11.6 to 203 psi) absolute

  • Temperature sensor

    NTC 30k

  • Ex certification

    With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
    hazardous areas Zone 0, Zone 1 and Zone 2

  • Connection

    Inductive, digital connection head with Memosens 2.0 technology

  • Ingress protection

    IP68

  • Meetprincipe

    Sensor ORP / Redox

  • Application

    pH / ORP sensor for heavily contaminated media
    and suspended solids
    • Chemical processes
    • Pulp and paper industry
    • Flue gas cleaning
    • Contaminated media:
    • Solids
    • Emulsions
    • Precipitation reactions

  • Characteristic

    Gel pH/ORP electrode with open aperture and double gel reference with ion trap for chemical applications

  • Measurement range

    ORP: –1 500 to 1 500 mV
    pH: 0 to 14

  • Measuring principle

    Pt-disc as additional ORP element
    rH measurement and control of the reference impedance

  • Design

    All shaft lengths with temperature sensor
    Advanced gel technology
    Hydrolysis stable gel

  • Material

    Sensor shaft: Glass to suit process
    pH membrane glass: Type B
    Metal lead: Ag/AgCl
    ORP measuring element: Platinum
    O-ring: FKM
    Process coupling: PPS fiber-glass reinforced
    Nameplate: Ceramic metal oxide

  • Dimension

    Diameter: 12 mm (0.46 inch)
    Shaft lengths: 120, 225, 360 and 425 mm
    (4.68, 8.77, 14.04 and 16.57 inch)

  • Process temperature

    0 to 110 °C (32 to 230 °F)

  • Process pressure

    0.8 to 14 bar (11.6 to 203 psi) absolute

  • Temperature sensor

    NTC 30k

  • Ex certification

    With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
    hazardous areas Zone 0, Zone 1 and Zone 2

  • Connection

    Inductive, digital connection head with Memosens 2.0 technology

  • Ingress protection

    IP68