iTHERM TMS02 MultiSens Flex Multipoint

iTHERM TMS02 MultiSens Flex Multipoint ©Endress+Hauser

Modular direct contact TC and RTD multipoint thermometer for oil, gas and petrochemical applications

The iTHERM TMS02 MultiSens Flex can be customized for various applications: Bendable into a 3D layout, it provides a complete temperature profile using only a single process connection. The device is configurable with or without thermowells for optimal response times, mechanical strength or sensors replaceability. It is available with either TC/RTD technology or with our iTHERM StrongSens and features an advanced diagnostics chamber for additional safety.

Dit product is niet verkrijgbaar in deze markt.

Snelle selectie

Kies uit één van de voorgestelde opties
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

of

Individuele configuratie

Ga verder met uw keuze uit alle mogelijke opties
  • Voordelen

    • Infinite layouts of 3D sensors distribution for any desired process monitoring configuration

    • High degree of customization thanks to a modular product design for easy installation, process integration and maintenance

    • High degree of insert process...

  • Toepassingsgebied

    • Petrochemical industry

    • Oil & Gas industry

    • Heavy Chemical processes

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Resistance Temperature Detector

  • Characteristic / Application

    metric style

    easy-to-use

    suitable for hazardous areas

    flanged process connection

    light chemical processes

    3D sensors distributions

    modular design

    replaceable sensors during shutdown

    diagnostic chamber

  • Terminal head

    Junction box - aluminium - as accessory

    Junction box - stainless steel - as accessory

    on board or remote Junction box

  • Thermowell / protection tube

    without (for direct contact sensors type)

    with (for replaceable sensors)

    with (for increased mechanical protection)

    Multi-thermowells, each one dedicated to a sensor

  • Insert / probe

    mineral insulated (MI), flexible

    mineral insulated (MI), flexible, with its own thermowell

  • Outer diameter protection tube / Insert

    6,0 mm (0,24'')

    8,0 mm (0,31")

    10,29 mm (1/8")

  • Max. immersion length on request

    up to 30.000,00 mm (1181'')

  • Material protection tube/ thermowell

    1.4401 (316)

    1.4435 (316L)

    1.4541 (321)

    1.4550 (347)

    Alloy 600 (2.4816)

  • Process connection

    flange:

    2" ASME/ANSI B16.5 150
    ...600

    3" ASME/ANSI B16.5 150
    ..600

    4" ASME/ANSI B16.5 150
    ...600

    6" ASME/ANSI B16.5 150
    ...600

    8" ASME/ANSI B16.5 150
    ...600

    DN80 EN/DIN 1092.1 PN10
    ...PN100

    DN100 EN/DIN 1092.1 PN10
    ...PN100

    DN125 EN/DIN 1092.1 PN10
    ...PN100

    DN150 EN/DIN 1092.1 PN10
    ...PN100

    DN200 EN/DIN 1092.1 PN10
    ...PN100

  • Tip shape

    straight

    reinforced

    easy-fix

  • Operating temperature range

    Type K:

    -270 °C ...1.100 °C

    (-454 °F ...2.012 °F)

    Type J:

    -210 °C ...760 °C

    (-346 °F ...1.382 °F)

    Type N:

    -270 °C …1100 °C

    (-454 °F ...752 °F)

    Pt100 WW; 3mm; 316L; -200...600oC

    Pt100 WW; 6mm; 316L; -200...600oC

    Pt100 TF; 3mm; 316L; -50…400oC

    Pt100 TF; 6mm; 316L; -50…400oC

    Pt100 StrongSens; 6mm; 316L; -50…500oC

  • Max. process pressure (static)

    at 20 °C: 200 bar (2900 psi)

  • Accuracy

    class 2 acc. to IEC 60584

    ASTM E230 and ANSI MC 96.1

    IEC/Class A

    IEC/Class AA

  • Response time

    depending on configuration:


    TC:

    t50 = 2 s

    t90 = 5 s


    RTD:

    t50 = 0,8s

    t90 = 2s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    ATEX

    IECEX

  • Certification

    SIL (transmitter only)

Documenten / handleidingen / software