Overzicht specificaties
-
Max. meetfout
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
-
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
-
Max. process pressure
PN 100, Class 600, 63K
-
Wetted materials
Measuring tube: Titanium grade 9
Connection: Titanium grade 2
Toepassingsgebied
De rechte enkelbuis Promass I flowmeter levert behalve massaflow-, dichtheids- en temperatuurmetingen ook in-line viscositeitsmetingen. Met zijn innovatieve transmitter op afstand optimaliseert de Promass I 500 installatieflexibiliteit en operationele veiligheid in veeleisende omgevingen. De Heartbeat Technologie maakt betrouwbare metingen en verificatie volgens de voorschriften mogelijk.
Meting wordt niet beïnvloed door fysische vloeistofeigenschappen, zoals viscositeit of dichtheid
Voor metingen in vloeistoffen en gassen in toepassingen met lage drukverliezen en voorzichtige vloeistofbehandeling.
Eigenschappen instrument
Recht, gemakkelijk te reinigen enkelbuis-systeem
TMB technology
Meetbuis van titanium
Versie met toegang op afstand met maximaal 4 I/O's
Display met achtergrondverlichting, aanraakbediening en WLAN-toegang
Standaardkabel tussen sensor en transmitter
Voordelen
Energiebesparend – het ontwerp met volle doorlaat zorgt voor minimale drukverliezen
Minder procesmeetpunten – multivariabele meting (flow, dichtheid, temperatuur)
Ruimtebesparende installatie – geen in-/uitlaatlengten nodig
Volledige toegang tot proces- en diagnose-informatie – talrijke, vrij te combineren I/O's en ethernet
Verminderde complexiteit en verscheidenheid – vrij configureerbare I/O-functionaliteit
Geïntegreerde verificatie – Heartbeat Technology
Video's
-
Het coriolis-flowmeetprincipe
Xpert selectie
-
Gespecialiseerde producten
- Ontworpen voor veeleisende applicaties
Technische topkwaliteit
Eenvoud
Variabel
-
Eenvoudige producten
- Gemakkelijk te selecteren, installeren en gebruiken
Technische topkwaliteit
Eenvoud
-
Standaardproducten
- Betrouwbaar, robuust en onderhoudsarm
Technische topkwaliteit
Eenvoud
-
Gespecialiseerde producten
- Ontworpen voor veeleisende applicaties
Technische topkwaliteit
Eenvoud
Variabel
| FLEX selectie | Technische topkwaliteit | Eenvoud |
|---|---|---|
Fundamental selectie Voldoe aan uw basismeetvoorwaarden |
Technische topkwaliteit
|
Eenvoud
|
Lean selectie Beheers eenvoudig uw belangrijkste processen |
Technische topkwaliteit
|
Eenvoud
|
Extended selectie Optimaliseer uw processen met innovatieve technologieën |
Technische topkwaliteit
|
Eenvoud
|
Xpert selectie Beheers uw meest uitdagende applicaties |
Technische topkwaliteit
|
Eenvoud
Variabel |
Voorganger
-
Meetprincipe
Coriolis
-
Product headline
Combines in-line viscosity and flow measurement with a transmitter remote version with up to 4 I/Os.
Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. -
Sensor features
Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. -
Nominal diameter range
DN 8 to 80 (⅜ to 3")
-
Wetted materials
Measuring tube: Titanium grade 9
Connection: Titanium grade 2 -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity
-
Max. meetfout
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
-
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L -
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
-
Degree of protection
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, EHEDG, cGMP
-
Meetprincipe
Coriolis
-
Product headline
Combines in-line viscosity and flow measurement with a transmitter remote version with up to 4 I/Os.
Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. -
Sensor features
Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. -
Nominal diameter range
DN 8 to 80 (⅜ to 3")
-
Wetted materials
Measuring tube: Titanium grade 9
Connection: Titanium grade 2 -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity
-
Max. meetfout
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
-
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L -
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
-
Degree of protection
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure" -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, EHEDG, cGMP
-
Meetprincipe
Coriolis
-
Product Headline
Combines in-line viscosity and flow measurement with a transmitter remote version with up to 4 I/Os.
Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. -
Sensor features
Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
-
Meetprincipe
Coriolis
-
Product headline
Combines in-line viscosity and flow measurement with a transmitter remote version with up to 4 I/Os.
Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. -
Sensor features
Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. -
Nominal diameter range
DN 8 to 80 (⅜ to 3")
-
Wetted materials
Measuring tube: Titanium grade 9
Connection: Titanium grade 2 -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity
-
Max. meetfout
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
-
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L -
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
-
Degree of protection
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, EHEDG, cGMP
-
Meetprincipe
Coriolis
-
Product headline
Combines in-line viscosity and flow measurement with a transmitter remote version with up to 4 I/Os.
Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. -
Sensor features
Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. -
Nominal diameter range
DN 8 to 80 (⅜ to 3")
-
Wetted materials
Measuring tube: Titanium grade 9
Connection: Titanium grade 2 -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity
-
Max. meetfout
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
-
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L -
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
-
Degree of protection
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, EHEDG, cGMP
-
-
Technische informatie (TI)
TI Proline Promass I 500
-
Technische informatie (TI)
Engelse versie - 12/2025New version available in EnglishCoriolis flowmeter
EN NL 01/12/202511/11/202501/11/202401/01/202116/09/2019Taal:
Engels
Versie:
01/12/2025
Bestandsgrootte:
9.5 MB
Bestandsnaam:
TI01284DEN_1125-00.pdf
-
-
-
Bedieningshandleiding (BA)
BA Proline Promass I 500
-
Bedieningshandleiding (BA)
Engelse versie - 12/2025New version available in EnglishCoriolis flowmeter
PROFINET over Ethernet-APLEN NL 01/12/202501/11/202408/01/2024Taal:
Engels
Versie:
01/12/2025
Bestandsgrootte:
9.7 MB
Bestandsnaam:
BA02126DEN_0325-00.pdf
-
-
-
Bedieningshandleiding (BA)
BA Proline Promass I 500
-
Bedieningshandleiding (BA)
Engelse versie - 12/2025New version available in EnglishCoriolis flowmeter
FOUNDATION fieldbusEN NL 01/12/202501/01/202101/11/2016Taal:
Engels
Versie:
01/12/2025
Bestandsgrootte:
8.7 MB
Bestandsnaam:
BA01564DEN_0425-00.pdf
-
-
-
Bedieningshandleiding (BA)
BA Proline Promass I 500
-
Bedieningshandleiding (BA)
Engelse versie - 12/2025New version available in EnglishCoriolis flowmeter
PROFINETEN NL 01/12/202501/01/202116/09/201915/07/201902/10/2017Taal:
Engels
Versie:
01/12/2025
Bestandsgrootte:
10.5 MB
Bestandsnaam:
BA01763DEN_0625-00.pdf
-
-
-
Bedieningshandleiding (BA)
BA Proline Promass I 500
-
Bedieningshandleiding (BA)
Engelse versie - 12/2025New version available in EnglishCoriolis flowmeter
Modbus TCPEN NL 15/12/202511/11/2025Taal:
Engels
Versie:
15/12/2025
Bestandsgrootte:
8.5 MB
Bestandsnaam:
BA02417DEN_0225-00.pdf
-
-
-
Bedieningshandleiding (BA)
BA Proline Promass I 500
-
Bedieningshandleiding (BA)
Engelse versie - 12/2025New version available in EnglishCoriolis flowmeter
Modbus RS485EN NL 01/12/202501/08/202201/01/202101/09/201902/10/2017Taal:
Engels
Versie:
01/12/2025
Bestandsgrootte:
8.7 MB
Bestandsnaam:
BA01542DEN_0725-00.pdf
-
-
-
Bedieningshandleiding (BA)
BA Proline Promass I 500
-
Bedieningshandleiding (BA)
Engelse versie - 12/2025New version available in EnglishCoriolis flowmeter
HARTEN NL 01/12/202501/08/202201/01/202101/09/2019Taal:
Engels
Versie:
01/12/2025
Bestandsgrootte:
8.9 MB
Bestandsnaam:
BA01531DEN_0725-00.pdf
-
-
-
Bedieningshandleiding (BA)
BA Proline Promass I 500
-
Bedieningshandleiding (BA)
Engelse versie - 12/2025New version available in EnglishCoriolis flowmeter
EtherNet/IPEN NL 01/12/202501/01/202102/10/2017Taal:
Engels
Versie:
01/12/2025
Bestandsgrootte:
9.5 MB
Bestandsnaam:
BA01752DEN_0425-00.pdf
-
-
-
Bedieningshandleiding (BA)
BA Proline Promass I 500
-
Bedieningshandleiding (BA)
Engelse versie - 12/2025New version available in EnglishCoriolis flowmeter
PROFIBUS PAEN NL 01/12/202501/01/202101/11/2018Taal:
Engels
Versie:
01/12/2025
Bestandsgrootte:
8.8 MB
Bestandsnaam:
BA01553DEN_0525-00.pdf
-
-
-
Bedieningshandleiding (BA)
BA Proline Promass I 500
-
Bedieningshandleiding (BA)
Engelse versie - 12/2025New version available in EnglishCoriolis flowmeter
PROFIBUS DPEN NL 01/12/202501/01/202101/06/2018Taal:
Engels
Versie:
01/12/2025
Bestandsgrootte:
8.3 MB
Bestandsnaam:
BA01875DEN_0425-00.pdf
-
Kies uit één van de voorgestelde opties
-
-- selected coding-- selected label99.999,00<%label%>
-
Zoekt u meer opties? Gebruik dan de individuele configurator om verder te gaan.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Zoekt u meer opties? Gebruik dan de individuele configurator om verder te gaan.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD-tekeningen CAD-tekeningen
- CAD-tekeningen
-
Prijzen per stuk
-
<%range%><%price%>
-
- Optionele extra's
Individuele configuratie
Vaak samen aangeschaft
Accessoires
Gerelateerde producten